Localized morphometric deformations of small airways and alveoli in intact mouse lungs under quasi-static inflation

被引:15
|
作者
Sera, T [1 ]
Uesugi, K [1 ]
Yagi, N [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst, SPring 8 JASRI, Sayo, Hyogo 6795198, Japan
关键词
three-dimensional visualization; fast synchrotron radiation CT; lung compliance; heterogeneity;
D O I
10.1016/j.resp.2005.02.003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Localized morphometric deformations of small airways and alveoli during respiration have several biomechanical and physiological implications. We developed fast synchrotron radiation CT system to visualize the small airways and alveoli of an intact mouse lung without fixation and dehydration, and analyzed their localized morphometric deformations between functional residual capacity (FRC) and total lung capacity (TLC). The maximum resolution of 32.61p/mm at the 5% modulation transfer function level can be achieved with 11.8-mu m voxels and 7-min scanning. Compared with the values at FRC, the diameter and length for smaller airways (diameter at FRC < 200 mu m) increased by 68.8% and 29.5% (averaged value), and those for larger airways (diameter at FRC > 400 mu m) increased by 45.2 and 22.9% (averaged value), at TLC. Moreover we defined the volume behavior as the percentage of airway volume at FRC for TLC. The volume behavior for the small airways was not similar to that of the lung volume. These results indicated that all airways did not behave homogenously. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 63
页数:13
相关论文
共 11 条
  • [1] Quasi-static solutions for quantum vortex motion under the localized induction approximation
    Lipniacki, T
    JOURNAL OF FLUID MECHANICS, 2003, 477 : 321 - 337
  • [2] Small airway changes in healthy and ovalbumin-treated mice during quasi-static lung inflation
    Sera, Toshihiro
    Uesugi, Kentaro
    Himeno, Ryutaro
    Yagi, Naoto
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2007, 156 (03) : 304 - 311
  • [3] NET v1.0: A framework to simulate permanent damage in elastomers under quasi-static deformations
    Morovati, Vahid
    Dargazany, Roozbeh
    SOFTWAREX, 2019, 10
  • [4] A novel device for measuring the ultrasonic wave velocity and the thickness of hyperelastic materials under quasi-static deformations
    Lo Savio, Fabio
    Bonfanti, Marco
    POLYMER TESTING, 2019, 74 : 235 - 244
  • [5] Design method for steel deck plates under quasi-static patch loads with allowable plastic deformations
    Zhu, Ling
    Cai, Wei
    Frieze, Paul A.
    Shi, Shiyun
    MARINE STRUCTURES, 2020, 71
  • [6] Transition rates for slip-avalanches in soft athermal disks under quasi-static simple shear deformations
    Saitoh, Kuniyasu
    Oyama, Norihiro
    Ogushi, Fumiko
    Luding, Stefan
    SOFT MATTER, 2019, 15 (17) : 3487 - 3492
  • [7] Synchrotron-based visualization and segmentation of elastic lamellae in the mouse carotid artery during quasi-static pressure inflation
    Trachet, Bram
    Ferraro, Mauro
    Lovric, Goran
    Aslanidou, Lydia
    Logghe, Gerlinde
    Segers, Patrick
    Stergiopulos, Nikolaos
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (155)
  • [8] Evolution of post-peak localized strain field of steel under quasi-static uniaxial tension: Analytical study
    Altai, Saif L.
    Orton, Sarah L.
    Chen, Zhen
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (04) : 435 - 449
  • [9] Brittle fracture development through sets of preexisting small-scale cracks under quasi-static and dynamic impact loading
    Uenishi, K.
    Nagasawa, K.
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2023, 30 (18) : 3710 - 3720
  • [10] Number of open lung units during an inflation-deflation cycle based on differences between small loop and quasi-static compliance of PL-VL curves
    Frazer, David G.
    Reynolds, Jeffrey S.
    Burdette, Nicholas
    McKinney, Walter
    Lindsley, William
    FASEB JOURNAL, 2007, 21 (06): : A827 - A827