Transcirculation approach for stent-assisted coiling of intracranial aneurysms: a multicenter study

被引:9
|
作者
Mascitelli, Justin R. [1 ]
Levitt, Michael R. [2 ]
Griessenauer, Christoph J. [3 ,4 ]
Kim, Louis J. [2 ]
Gross, Bradley [5 ]
Abla, Adib [6 ]
Winkler, Ethan [6 ]
Jankowitz, Brian [7 ]
Grandhi, Ramesh [8 ]
Goren, Oded [3 ]
Schirmer, Clemens M. [3 ,4 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Neurosurg, San Antonio, TX 78229 USA
[2] Univ Washington, Sch Med, Dept Neurosurg, Seattle, WA USA
[3] Geisinger Hlth Syst, Dept Neurosurg, Danville, PA USA
[4] Paracelsus Med Univ, Res Inst Neurointervent, Salzburg, Austria
[5] Univ Pittsburgh, Med Ctr, Dept Neurosurg, Pittsburgh, PA USA
[6] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA USA
[7] Cooper Univ Hlth Care, Dept Neurosurg, Camden, NJ USA
[8] Univ Utah, Dept Neurosurg, Salt Lake City, UT USA
关键词
aneurysm; stent; technique; coil; INFERIOR CEREBELLAR ARTERY; WIDE-NECKED ANEURYSMS; BASILAR-TIP ANEURYSM; ENDOVASCULAR TREATMENT; BIFURCATION ANEURYSMS; EMBOLIZATION; PLACEMENT; DEPLOYMENT; COMPLEX;
D O I
10.1136/neurintsurg-2020-016899
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background The transcirculation approach (TCA) for stent-assisted coiling (SAC) of intracranial aneurysms may be useful for certain wide-neck bifurcation aneurysms as well as those with acute-angle efferent branches. Objective To describe a multicenter experience using the TCA for SAC. Methods A multicenter, retrospective study (2016-2020) of aneurysm treatment using SAC via the TCA. Angiographic outcome was scored using the Raymond Scale (adequate occlusion 1 and 2), and clinical outcome was scored using a modified Rankin Scale (good outcome 0-2) Results Twenty-nine patients with 29 aneurysms were included (62.1% female; average age 61; 89.7% unruptured; 13.8% previously treated; average dome size 6.4 mm; average neck 4.4 mm). Aneurysm locations included internal carotid artery-fetal posterior cerebral artery (n=4), internal carotid artery terminus (n=4), anterior communicating artery (n=8), vertebral artery-posterior inferior cerebellar artery (n=2), and basilar tip (n=11). The TCA used communicating arteries (93.1%; average 1.6 mm), intermediate catheters (51.7%), jailing technique (62.1%), and staged procedures (10.3%). The most common stent was the Neuroform Atlas (Stryker; 69%). Immediate adequate occlusion was obtained in 75.9%, and five patients with inadequate occlusion progressed to adequate occlusion at follow-up. One (3.4%) procedural complication occurred: a watershed stroke in the setting of baseline four-vessel extracranial disease. Two patients had a poor outcome unrelated to the TCA. The majority of patients (86.4%) had a good clinical outcome. One case of in-stent stenosis due to non-compliance with medication was seen, which resolved with medication resumption. Conclusions The TCA for SAC can be performed for a variety of aneurysms with a low complication rate and good clinical outcomes.
引用
收藏
页码:711 / +
页数:6
相关论文
共 50 条
  • [1] Neuroform Atlas stent-assisted coiling of ruptured intracranial aneurysms: A multicenter study
    Russo, Riccardo
    Bradac, Gianni Boris
    Castellan, Lucio
    Gallesio, Ivan
    Garbossa, Diego
    Iannucci, Giuseppe
    Mardighian, Dikran
    Menozzi, Roberto
    Pitrone, Antonio
    Romano, Giuseppe
    Venturi, Fabrizio
    Bergui, Mauro
    JOURNAL OF NEURORADIOLOGY, 2021, 48 (06) : 479 - 485
  • [2] Stent-assisted Coiling of Complex Intracranial Aneurysms
    Deng, Dongfeng
    Sun, Hui
    Jin, Dianshi
    Qu, Kai
    Zhou, Jinbin
    Piao, Xiangyu
    Cai, Ming
    Zhang, Yanli
    Sun, Ruitan
    NEUROSURGERY QUARTERLY, 2012, 22 (03) : 153 - 158
  • [3] Stent-assisted coiling versus coiling alone of poor-grade ruptured intracranial aneurysms: a multicenter study
    Zhao, Bing
    Tan, Xianxi
    Yang, Hua
    Zheng, Kuang
    Li, Zequn
    Xiong, Ye
    Zhong, Ming
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (02) : 165 - U40
  • [4] Stent-Assisted Coiling of Cerebral Aneurysms: A Multicenter Analysis
    Mokin, Maxim
    Primiani, Christopher T.
    Piper, Keaton
    Fiorella, David
    Rai, Ansaar
    Orlov, Kirill
    Kislitsin, Dmitry
    Gorbatykh, Anton
    Mocco, J. D.
    DeLeacy, Reade
    Lee, Joyce
    Spiotta, Alejandro M.
    Turner, Raymond D.
    Chaudry, Imran
    Turk, Aquilla S.
    NEUROSURGERY, 2019, 66 : 147 - 147
  • [5] A Multicenter Study of Stent-Assisted Coiling of Cerebral Aneurysms With a Y Configuration
    Fargen, Kyle M.
    Mocco, J.
    Neal, Dan
    Dewan, Michael C.
    Reavey-Cantwell, John
    Woo, Henry H.
    Fiorella, David J.
    Mokin, Maxim
    Siddiqui, Adnan H.
    Turk, Aquilla S.
    Turner, Raymond D.
    Chaudry, Imran
    Kalani, M. Yashar S.
    Albuquerque, Felipe
    Hoh, Brian L.
    NEUROSURGERY, 2013, 73 (03) : 466 - 472
  • [6] Safety and efficacy of the Neuroform Atlas for stent-assisted coiling of intracranial aneurysms: A multicenter experience
    Goertz, Lukas
    Dorn, Franziska
    Siebert, Eberhard
    Herzberg, Moriz
    Borggrefe, Jan
    Schlamann, Marc
    Krischek, Boris
    Stavrinou, Pantelis
    Mpotsaris, Anastasios
    Bohner, Georg
    Liebig, Thomas
    Kabbasch, Christoph
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 68 : 86 - 91
  • [7] Stent-Assisted Coiling May Prevent the Recurrence of Very Small Ruptured Intracranial Aneurysms: A Multicenter Study
    Zhang, Yisen
    Yang, Ming
    Zhang, Hongqi
    Zhang, Xiaolong
    Li, Youxiang
    Jiang, Chuhan
    Liu, Jian
    Yang, Xinjian
    WORLD NEUROSURGERY, 2017, 100 : 22 - 29
  • [8] Clinical and angiographic outcomes of stent-assisted coiling of intracranial aneurysms
    Ghinda, Diana
    dos Santos, Marlise Peruzzo
    Sabri, Armin
    Iancu, Daniela
    Lum, Cheemun
    Lesiuk, Howard J.
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (02) : 146 - 154
  • [9] Threshold for Packing Density in Stent-Assisted Coiling of Intracranial Aneurysms
    Chalouhi, Nohra
    Dumont, Aaron S.
    Tjoumakaris, Stavropoula I.
    Gonzalez, Fernando
    Starke, Robert M.
    Dalyai, Richard
    El Moursi, Sedeek
    Rosenwasser, Robert H.
    Hasan, David M.
    Jabbour, Pascal
    NEUROSURGERY, 2012, 71 (02) : E553 - E553
  • [10] Comparison of Devices Used for Stent-Assisted Coiling of Intracranial Aneurysms
    Izar, Benjamin
    Rai, Ansaar
    Raghuram, Karthikram
    Rotruck, Jill
    Carpenter, Jeffrey
    PLOS ONE, 2011, 6 (09):