Laparoendoscopic Single-Site Nephrectomy Using a Modified Umbilical Incision and a Home-Made Transumbilical Port

被引:5
|
作者
Yu, Ho Song
Ham, Won Sik
Rha, Koon Ho
Han, Sang Won
Choi, Young Deuk
Han, Woong Kyu
Chang, Won Sik [1 ]
机构
[1] Yonsei Univ, Dept Urol, Coll Med, Seoul 102752, South Korea
关键词
Laparoendoscopic single-site surgery; nephrectomy; home-made transumbilical port; modified umbilical incision; LAPAROSCOPIC NEPHRECTOMY; CLINICAL REPORT; SURGERY; EXPERIENCE; UROLOGY; DEVICE;
D O I
10.3349/ymj.2011.52.2.307
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess the clinical utility of laparoendoscopic single-site surgery (LESS) nephrectomy using a modified umbilical incision and home-made transumbilical port in cases requiring extirpative surgery. Materials and Methods: Initial consecutive 18 patients underwent LESS nephrectomies that were performed by a single surgeon. A home-made port was placed through a modified umbilical incision, the length of which had preoperatively been determined. The laparoscopic transperitoneal nephrectomy procedures were performed with various combinations of standard and articulating laparoscopic instruments. Patient characteristics and perioperative outcomes, including pathologic results, were recorded prospectively. Results: All 18 extirpative surgeries, including simple nephrectomy (eight cases), radical nephrectomy (nine cases), and nephroureterectomy (one case), were completed successfully. The median operation time was 167 min (range 82-220), and the median blood loss was 250 mL (range 0-1050). All specimens were extracted intact through a modified umbilical incision (median length 2.5 cm, range 1.5-6.0). Final pathological analysis revealed a nonfunctioning kidney in five cases, a dysplastic kidney in three cases, a mixed epithelial and stromal tumor in one case, renal cell carcinoma in eight cases (T1: five cases, T3: three cases), and Ta ureter transitional cell carcinoma in one case. Conclusion: LESS nephrectomy using a homemade port and modified umbilical incision is feasible with both minimal incision and cost-effective. Our technique may be more useful for extirpative procedures in which a specimen needs to be removed intact, because incision length can be freely adjusted. Prospective comparisons are warranted to more clearly elucidate the utility of this surgical technique.
引用
收藏
页码:307 / 313
页数:7
相关论文
共 50 条
  • [1] LAPAROENDOSCOPIC SINGLE-SITE NEPHRECTOMY USING A MODIFIED UMBILICAL INCISION AND A HOMEMADE TRANSUMBILICAL PORT
    Ham, Won Sik
    Yu, Ho Song
    Chang, Won Sik
    Han, Woong Kyu
    Rha, Koon Ho
    Han, Sang Won
    Choi, Young Deuk
    Hong, Sung Joon
    JOURNAL OF UROLOGY, 2010, 183 (04): : E280 - E280
  • [2] LAPAROENDOSCOPIC SINGLE-SITE NEPHRECTOMY USING A MODIFIED UMBILICAL INCISION AND A HOMEMADE TRANSUMBILICAL PORT
    Yu, H. S.
    Chang, W. S.
    Han, W. K.
    Rha, K. H.
    Han, S. W.
    Choi, Y. D.
    Hong, S. J.
    Ham, W. S.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (02) : 245 - 245
  • [3] The Feasibility of Laparoendoscopic Single-Site Nephrectomy: Initial Experience Using Home-made Single-port Device
    Han, Woong Kyu
    Park, Yong Hyun
    Jeon, Hwang Gyun
    Jeong, Wooju
    Rha, Koon Ho
    Choi, Hwang
    Kim, Hyeon Hoe
    UROLOGY, 2010, 76 (04) : 862 - 865
  • [4] THE FEASIBILITY OF LAPAROENDOSCOPIC SINGLE-SITE NEPHRECTOMY: INITIAL EXPERIENCE USING HOME-MADE SINGLE-PORT DEVICE
    Park, Y.
    Jeon, H.
    Han, W.
    Yang, S.
    Jeong, H.
    Kim, H.
    JOURNAL OF ENDOUROLOGY, 2009, 23 : A313 - A313
  • [5] Preliminary experience with transperitoneal laparoendoscopic single-site radical nephrectomy using a home-made single-port device in China
    Bi Hai
    Ma Lulin
    Hou Xiaofei
    Zhang Shudong
    Wang Guoliang
    Zhao Lei
    中华医学杂志(英文版), 2014, 127 (02) : 279 - 283
  • [6] Preliminary experience with transperitoneal laparoendoscopic single-site radical nephrectomy using a home-made single-port device in China
    Bi Hai
    Ma Lulin
    Hou Xiaofei
    Zhang Shudong
    Wang Guoliang
    Zhao Lei
    CHINESE MEDICAL JOURNAL, 2014, 127 (02) : 279 - 283
  • [7] Transumbilical laparoendoscopic single-site donor nephrectomy: Without the use of a single port access device
    Dubey, Deepak
    Shrinivas, R. P.
    Srikanth, G.
    INDIAN JOURNAL OF UROLOGY, 2011, 27 (02) : 180 - 184
  • [8] Transumbilical laparoendoscopic single-site donor nephrectomy: evolving trends
    El Hennawy, Hany M.
    Al Hashemy, Ahmed
    Kadi, Najib M.
    Jameel, Muhammed M.
    Al Faifi, Abdullah S.
    Habhab, Wael T.
    Fahmy, Ahmed E.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (06): : 1920 - 1926
  • [9] Transumbilical laparoendoscopic single-site donor nephrectomy: evolving trends
    Hany M. El Hennawy
    Ahmed Al Hashemy
    Najib M. Kadi
    Muhammed M. Jameel
    Abdullah S. Al Faifi
    Wael T. Habhab
    Ahmed E. Fahmy
    Surgical Endoscopy, 2019, 33 : 1920 - 1926
  • [10] LAPAROENDOSCOPIC SINGLE-SITE SURGERY FOR BENIGN UROLOGIC DISEASE USING HOME-MADE SINGLE PORT: FOCUS ON EASY TECHNIQUE AND TIPS
    Chung, Jae Hoon
    Lee, Joo Yong
    Park, Sung Yul
    Cho, Kang Su
    Ham, Won Sik
    Moon, Hong Sang
    Lee, Tchun Yong
    Lee, Seung Wook
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A271 - A272