A current-mode control technique with instantaneous inductor-current feedback for UPS inverters

被引:36
|
作者
Wu, HY [1 ]
Lin, D [1 ]
Zhang, DH [1 ]
Yao, KW [1 ]
Zhang, JF [1 ]
机构
[1] Zhejiang Univ, Dept Elect Engn, Hangzhou 310027, Peoples R China
关键词
D O I
10.1109/APEC.1999.750484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A current-mode control technique with output filter inductor-current instantaneously controlled is proposed for voltage-source inverter of uninterruptible power supplies (UPS's). This technique shows good dynamic responsibility, high stability and current limiting in case of load short. Small-signal analysis, parameter design, simulation and experimental results are given in this paper.
引用
收藏
页码:951 / 957
页数:3
相关论文
共 50 条
  • [1] Inductor Current Sampled Feedback Control of Chaos in Current-Mode Boost Converter
    Bo-Cheng Bao and Yan Liang
    Journal of Electronic Science and Technology of China, 2008, (01) : 52 - 55
  • [2] Current-Mode Pulse-Train Control Techniques for Buck Converter: Inductor-Current PT and Capacitor-Current PT
    Ignace, Gasore
    Sha, Jin
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 524 - 529
  • [3] Control of bifurcation for a current-mode DC/DC boost converter by self-inductor current feedback
    Khaehintung, Noppadol
    Sirisuk, Phaophak
    Wiangtong, Theerayod
    2006 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES,VOLS 1-3, 2006, : 1068 - +
  • [4] Communicationless parallel inverters based on inductor current feedback control
    Ju, Hongxin
    Ding, Ming
    Su, Jianhui
    Du, Yan
    Chang, Liuchen
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1385 - +
  • [5] Current limitation control technique for parallel operation of UPS inverters
    Chiang, SJ
    Lin, CH
    Yen, CY
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 1922 - 1926
  • [6] Parameters Design and Optimization for LC-Type Off-Grid Inverters With Inductor-Current Feedback Active Damping
    Geng, Yiwen
    Yun, Yang
    Chen, Ruicheng
    Wang, Kai
    Bai, Haofeng
    Wu, Xiaojie
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (01) : 703 - 715
  • [7] Dynamic Ramp with the Invariant Inductor in Current-Mode Control for Buck Converter
    Chen, Wen-Wei
    Chen, Jiann-Fuh
    Liang, Tsorng-Juu
    Ting, Wei-Yuan
    Wei, Lu-Chi
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 1244 - 1249
  • [8] RF pure current-mode filters using current mirrors and inverters
    Jerabek, Jan
    Vrba, Kamil
    PERSONAL WIRELESS COMMUNICATIONS, 2007, 245 : 545 - +
  • [9] Non-linear passive control with inductor current feedback for an UPS inverter
    Alarcón, C
    Cárdenas, V
    Ramírez, S
    Visairo, N
    Nuñez, C
    Oliver, M
    Sira-Rimírez, H
    PESC 2000: 31ST ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-3, 2000, : 1414 - 1418
  • [10] A CONTROL STRATEGY BY INSTANTANEOUS AVERAGE VALUES FOR PARALLEL OPERATION OF SINGLE PHASE VOLTAGE SOURCE INVERTERS BASED IN THE INDUCTOR CURRENT FEEDBACK
    Lazzarin, Telles B.
    Bauer, Guilherme A. T.
    Barbi, Ivo
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 899 - 906