Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance

被引:108
|
作者
Heller, JG [1 ]
Estes, BT [1 ]
Zaouali, M [1 ]
Diop, A [1 ]
机构
[1] ECOLE NATL SUPER ARTS & METIERS,DEPT BIOMECH ENGN,F-75013 PARIS,FRANCE
来源
关键词
D O I
10.2106/00004623-199609000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate the effects of the design of the screw the depth of insertion, the vertebral level, and the quality of the host bone on the pull-out resistance of screws used in the lateral masses, The study included twelve fresh cervical spines from human cadavera, Radiographs were made of each specimen to ensure the absence of defects, and then the cancellous-bone density of the vertebral bodies was measured at each level with quantitative computed tomography scanning, Six commercially available screws of various diameters and thread configurations (2.7, 3.2, 3.5, and 4.5-millimeter cortical-bone screws; a 3.5-millimeter cancellous-bone screw; and a 3.5-millimeter self-tapping screw) that are currently used for fixation of the cervical lateral masses were tested for axial load to failure, A twelve-by-twelve Latin square design was used to randomize the screws with regard to level (second through seventh cervical vertebrae), side (right and left), and depth of insertion (unicortical or bicortical purchase), Each screw was then subjected to uniaxial load to failure, The data were analyzed to determine if the diameter of the screw, the thread configuration, the number of cortices engaged, the cervical level, or the bone density was associated with the load to failure, Three major subgroups (greatest, intermediate, and lowest pull-out resistance) were identified, The subgroup with the greatest pull-out resistance included only screws with bicortical purchase; the 3.2, 3.5, and 4.5-millimeter cortical-bone screws and the 3.5-millimeter cancellous-bone screw were in this subgroup, Regardless of the thread configuration, no screw with unicortical purchase was in the group with the greatest pull-out resistance, Two of the three values in the subgroup with the lowest pull-out resistance were for the 3.5-millimeter self-tapping screw (with unicortical or bicortical purchase), The cancellous-bone density of the vertebral body was not associated with pull-out resistance and it did not vary significantly according to the cervical level, with the numbers available, However, the pull-out resistance of the screws varied significantly (p = 0.004) by level: it was the greatest at the fourth cervical level, decreasing cephalad and caudad to that level, CLINICAL RELEVANCE: Posterior plate fixation of the cervical spine with screws inserted into the lateral masses may be appropriate in certain circumstances, Previous studies on cadavera and clinical experience have attested to the potential pitfalls of fixation with screws in the lateral masses, Our data suggest that the surgeon should consider not only the type and size of the screws but also whether unicortical or bicortical purchase should be achieved, Bicortical purchase engenders a greater risk of injury to local anatomical structures, but this may be an acceptable compromise at the cephalad and caudad regions of the cervical spine, where the purchase of screws is relatively weaker.
引用
收藏
页码:1315 / 1321
页数:7
相关论文
共 50 条
  • [1] The Effect of Hubbing on the Pull-out Strength of Lateral Mass Screws in the Cervical Spine A Biomechanical Experiment
    Koo, Ki Hyoung
    Yoon, S. Tim
    Kim, Sang Bum
    Hutton, William C.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (01): : E45 - E48
  • [2] Does augmentation increase the pull-out force of symphyseal screws? A biomechanical cadaver study
    Kussmaul, Adrian Cavalcanti
    Schwaabe, Fanny
    Becker, Christopher Alexander
    Kleber, Christian
    Linhart, Christoph
    Thorwaechter, Christoph
    Rubenbauer, Bianka
    Boecker, Wolfgang
    Greiner, Axel
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (05) : 4215 - 4221
  • [3] Does augmentation increase the pull-out force of symphyseal screws? A biomechanical cadaver study
    Adrian Cavalcanti Kußmaul
    Fanny Schwaabe
    Christopher Alexander Becker
    Christian Kleber
    Christoph Linhart
    Christoph Thorwächter
    Bianka Rubenbauer
    Wolfgang Böcker
    Axel Greiner
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4215 - 4221
  • [4] Biomechanical pull-out strength of the cervical spine locking plate (CSLP) expansion screws
    Mitchell, DW
    Betcher, RA
    Littlejohn, SG
    Dillon, LD
    McGuire, RA
    Zardiackas, LD
    PROCEEDINGS OF THE 1997 16TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1997, : 151 - 154
  • [5] PULL-OUT STRENGTH OF CASPAR CERVICAL SCREWS
    MAIMAN, DJ
    PINTAR, FA
    YOGANANDAN, N
    REINARTZ, J
    TOSELLI, R
    WOODWARD, E
    HAID, R
    NEUROSURGERY, 1992, 31 (06) : 1097 - 1101
  • [6] Screw Osteointegration-Increasing Biomechanical Resistance to Pull-Out Effect
    Costachescu, Bogdan
    Niculescu, Adelina-Gabriela
    Grumezescu, Alexandru Mihai
    Teleanu, Daniel Mihai
    MATERIALS, 2023, 16 (16)
  • [7] Pull-out strength of the suprapedicle claw construct: a biomechanical study
    Abdulrazzaq Alobaid
    Vincent Arlet
    Andre Busato
    Thomas Steffen
    European Spine Journal, 2005, 14 : 759 - 764
  • [8] Pull-out strength of the suprapedicle claw construct: a biomechanical study
    Alobaid, A
    Arlet, V
    Busato, A
    Steffen, T
    EUROPEAN SPINE JOURNAL, 2005, 14 (08) : 759 - 764
  • [9] PULL-OUT STRENGTH OF CASPAR CERVICAL SCREWS - REPLY
    MAIMAN, DJ
    NEUROSURGERY, 1993, 33 (01) : 172 - 172
  • [10] PULL-OUT STRENGTH OF SCREWS FROM POLYMETHYLMETHACRYLATE CEMENT
    MOTZKIN, NE
    CHAO, EYS
    AN, KN
    WIKENHEISER, MA
    LEWALLEN, DG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02): : 320 - 323