2D nonuniform array design for imaging applications

被引:0
|
作者
Moebus, Marco [1 ]
Zoubir, Abdelhak M. [1 ]
机构
[1] Tech Univ Darmstadt, Signal Proc Grp, D-64283 Darmstadt, Germany
关键词
nonuniformly spaced arrays; planar arrays; redundancy; design automation; acoustic imaging;
D O I
10.1109/WSA.2008.4475556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We address the problem of non-uniform, planar array design with an emphasis on imaging applications. Based on the theory of minimum redundancy arrays, we propose an iterative algorithm that is capable to design highly thinned arrays with a low side-lobe level while retaining the Half-Power-Beam-Width of an uniform rectangular array. The computational complexity of the proposed method is substantially lower than for existing methods. The algorithm is applied to real data to demonstrate the effectiveness of the method.
引用
收藏
页码:180 / 183
页数:4
相关论文
共 50 条
  • [1] OPTIMIZED 2D ARRAY DESIGN FOR ULTRASOUND IMAGING
    Diarra, Bakary
    Liebgott, Herve
    Robini, Marc
    Tortoli, Piero
    Cachard, Christian
    2012 PROCEEDINGS OF THE 20TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2012, : 2718 - 2722
  • [2] 2D array design based on Fermat spiral for ultrasound imaging
    Martinez-Graullera, Oscar
    Martin, Carlos J.
    Godoy, Gregorio
    Ullate, Luis G.
    ULTRASONICS, 2010, 50 (02) : 280 - 289
  • [3] Design and Characterization of a 2D Array of MEMS Microphones for Acoustical Imaging
    Izquierdo, A.
    Villacorta, J. J.
    del Val, L.
    Suarez, L. A.
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA), 2016, : 130 - 132
  • [4] 3D ultrasound coherence imaging based on 2D array design
    Jia, Yanping
    Xu, Mengling
    Ding, Mingyue
    Yuchi, Ming
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [5] Imaging with a 2D transducer hybrid array
    Erikson, K
    Stockwell, J
    Hairston, A
    Rich, G
    Marciniec, J
    Walter, L
    Clark, K
    White, T
    ACOUSTICAL IMAGING, VOL 24, 2000, 24 : 9 - 20
  • [6] Sparse 2D array design optimization for imaging systems using genetic algorithm
    Perez-Eijo, Lorena
    Arias, Marcos
    Gonzalez-Valdes, Borja
    Pino, Antonio
    Rubinos, Oscar
    Grajal, Jesus
    2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,
  • [7] PROPERTIES FOR A 2D MULTIPLEXED ARRAY FOR ACOUSTIC IMAGING
    GELLY, JF
    MAERFELD, C
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 192 - 193
  • [8] 2D optoacoustic array for high resolution imaging
    Ashkenazi, S.
    Witte, R. S.
    Kim, K.
    Huang, S. -W.
    Hou, Y.
    O'Donnell, M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2006, 2006, 6086
  • [9] Transcranial ultrasonic imaging with 2D synthetic array
    Tsysar, S. A.
    Khokhlova, V. A.
    Sapozhnikov, O. A.
    Kreider, W.
    Khokhlova, V. A.
    Sapozhnikov, O. A.
    Svet, V. D.
    Molotilov, A. M.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [10] HEXAGONAL ARRAY STRUCTURE FOR 2D NDE APPLICATIONS
    Dzicwicrz, J.
    Ramadas, S. N.
    Gachagan, A.
    O'Leary, R. L.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B, 2010, 1211 : 825 - 830