Dispersive Micro-solid Phase Extraction with Fibrous TiO2@g-C3N4 Nanocomposites Coupled with ICP-MS for the Determination of Cobalt and Nickel in Environmental and Biological Samples

被引:8
|
作者
Chen, Shizhong [1 ]
Liu, Yuxiu [2 ]
Yan, Juntao [2 ]
Wang, Chunlei [2 ]
Lu, Dengbo [1 ]
机构
[1] Wuhan Polytech Univ, Coll Food Sci & Engn, Wuhan 430023, Peoples R China
[2] Wuhan Polytech Univ, Coll Chem & Environm Engn, Wuhan 430023, Peoples R China
关键词
GRAPHITIC CARBON NITRIDE; ORGANIC DROP MICROEXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; RARE-EARTH-ELEMENTS; HEAVY-METAL IONS; TEA INFUSION; ONLINE PRECONCENTRATION; ZNFE2O4; NANOTUBES; TRACE-ELEMENTS;
D O I
10.46770/AS.2020.04.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, fibrous TiO2@g-C3N4 nanocomposites (FTGCNCs) were used for dispersive micro-solid phase extraction of Co and Ni prior to their determination by inductively coupled plasma mass spectrometry. As a new adsorbent, the surface on FTGCNCs have rich functional groups such as -NH2, -NH- and =N-, which can selectively adsorb target ions. The adsorption behaviors of Co and Ni on FTGCNCs were investigated. The results indicated that the analytes were quantitatively retained on FTGCNCs in the pH range of 5.0-8.0 and eluted completely with 1.0 mL of 0.5 mol L-1 HNO3 solution. The main factors influencing the preconcentration and determination of the analytes were investigated in detail, including the pH of the sample solution dosage of adsorbent, extraction/elution time, elution parameters and sample volumes. Under the optimum conditions, the detection limits of this method were 0.12 pg mL(-1) and 1.34 pg mL(-1) for Co and Ni, respectively. The relative standard deviations were 3.9% for Co and 4.8% for Ni (n=9, c=1.0 ng mL(-1)). This method was used for the determination of trace/ultra-trace Co and Ni in environmental water samples with satisfactory results. In order to verify this method, three certified reference materials of stream sediment, human hair and mussel were analyzed using the proposed method, and the determined results were in agreement with the certified values.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [1] Determination of Antimony Speciation in Cow Milk Using Dispersive Micro-solid Phase Extraction Based on Fibrous TiO2@g-C3N4 Nanocomposites and ICP-MS After Sample Pretreatment by Artificial Gastric Juice
    Shizhong Chen
    Yuxiu Liu
    Chunlei Wang
    Juntao Yan
    Dengbo Lu
    Food Analytical Methods, 2020, 13 : 2102 - 2110
  • [2] Determination of Antimony Speciation in Cow Milk Using Dispersive Micro-solid Phase Extraction Based on Fibrous TiO2@g-C3N4Nanocomposites and ICP-MS After Sample Pretreatment by Artificial Gastric Juice
    Chen, Shizhong
    Liu, Yuxiu
    Wang, Chunlei
    Yan, Juntao
    Lu, Dengbo
    FOOD ANALYTICAL METHODS, 2020, 13 (11) : 2102 - 2110
  • [3] Fibrous g-C3N4@Tio2 Nanocomposites-Based Dispersive Micro-Solid Phase Extraction for Chromium Speciation in Cow Milk by ICP-MS after Digestion Treatment with Artificial Gastric Juice
    Chen, Shizhong
    Liu, Yuxiu
    Yan, Juntao
    Wang, Chunlei
    Lu, Dengbo
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (01) : 129 - 136
  • [4] Dispersive Micro-solid Phase Extraction Coupled With Dispersive Liquid-liquid Microextraction for Speciation of Antimony in Environmental Water Samples by Electrothermal Vaporization ICP-MS
    Chen, Shizhong
    Zhu, Shengping
    Lu, Dengbo
    ATOMIC SPECTROSCOPY, 2018, 39 (02) : 55 - 61
  • [5] Use of fibrous TiO2@graphitic carbon nitride nanocomposites in dispersive micro-solid phase extraction for arsenic species before inductively coupled plasma mass spectrometry determination
    Chen, Shizhong
    Wang, Chunlei
    Yan, Juntao
    Lu, Dengbo
    MICROCHEMICAL JOURNAL, 2020, 158
  • [6] Microwave-assisted solid phase extraction prior to ICP-MS determination of Pd and Pt in environmental and biological samples
    Kovachev, N.
    Sanchez, A.
    Simitchiev, K.
    Stefanova, V.
    Kmetov, V.
    Canals, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (09) : 1106 - 1119
  • [7] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Zhang, Nan
    Peng, Hanyong
    Wang, Shen
    Hu, Bin
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 121 - 128
  • [8] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Nan Zhang
    Hanyong Peng
    Shen Wang
    Bin Hu
    Microchimica Acta, 2011, 175 : 121 - 128
  • [9] Spin-column micro-solid phase extraction coupled with LC-MS for the determination of new synthetic cannabinoids in biological samples
    Yao, Weixuan
    Chen, Nanxu
    Zhang, Suling
    Wang, Jiye
    Wu, Yuanzhao
    Wang, Binjie
    Chinese Journal of Analysis Laboratory, 2023, 42 (09) : 1215 - 1220
  • [10] Carboxylated nanodiamonds@CuAl2O4@TiO2 nanocomposite for the dispersive micro-solid phase extraction of nickel at trace levels from food samples
    Soylak, Mustafa
    Aksu, Birgul
    Ahmed, Hassan Elzain Hassan
    FOOD CHEMISTRY, 2024, 445