Unstable subtrochanteric fractures - gamma nail versus dynamic condylar screw

被引:25
|
作者
Pakuts, AJ [1 ]
机构
[1] Hosp Reg Coquimbo, Dept Orthopaed, La Serena, Chile
关键词
D O I
10.1007/s00264-003-0497-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the operative treatment of subtrochanteric fractures. Before 1999, 15 fractures were treated with a dynamic condylar screw (DCS) and after 1999, 11 fractures were treated with a gamma nail (GN). The mean age of all patients was 70 (31-92) years, and the mean follow up was 16 (9-30) months for the DCS group and 14 (6-26) months for the GN group. All fractures united. There were no infections or implant cut out. In the DCS group, there was one malunion in varus and one late fracture of the implant. In the GN group, there was one malunion in internal rotation and three intraoperative fractures. Functional evaluation showed no significant differences in pain, range of movement, or walking ability, but recovery was significantly earlier in the GN group.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [1] Unstable subtrochanteric fractures—gamma nail versus dynamic condylar screw
    Andrés J. Pakuts
    International Orthopaedics, 2004, 28 : 21 - 24
  • [2] Subtrochanteric Fractures Treated With Dynamic Condylar Screw
    Sahito, Badaruddin
    Khaskheli, Javed Hussain
    Kumar, Dileep
    Lakho, Muhammad Tahir
    Younis, Muhammad
    Ayub, Arsalan Khalil
    ANNALS ABBASI SHAHEED HOSPITAL & KARACHI MEDICAL & DENTAL COLLEGE, 2022, 27 (01): : 265 - 270
  • [3] Results of dynamic condylar screw for subtrochanteric fractures
    Kulkarni, SS
    Moran, CG
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (02): : 117 - 122
  • [4] THE DYNAMIC CONDYLAR SCREW IN SUBTROCHANTERIC FRACTURES OF THE FEMUR
    HAMMACHER, ER
    BAST, TJ
    VANRAMSHORST, B
    SYBRANDY, R
    NETHERLANDS JOURNAL OF SURGERY, 1988, 40 (06): : 158 - 159
  • [5] TREATMENT OF SUBTROCHANTERIC FRACTURES WITH THE AO DYNAMIC CONDYLAR SCREW
    NUNGU, KS
    OLERUD, C
    REHNBERG, L
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1993, 24 (02): : 90 - 92
  • [6] Intramedullary nail versus sliding hip screw for stable and unstable trochanteric and subtrochanteric fractures
    Gronhaug, K. M. L.
    Dybvik, E.
    Matre, K.
    Ostman, B.
    Gjertsen, J-E.
    BONE & JOINT JOURNAL, 2022, 104B (02): : 274 - 282
  • [7] THE DYNAMIC CONDYLAR SCREW IN THE MANAGEMENT OF SUBTROCHANTERIC FRACTURES OF THE FEMUR
    WARWICK, DJ
    CRICHLOW, TPKR
    LANGKAMER, VG
    JACKSON, M
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (04): : 241 - 244
  • [8] Results of subtrochanteric fractures treated with dynamic hip screw and dynamic condylar screw
    Khallaf, FGM
    Al-Rowaih, A
    Abdul-Hamid, HF
    MEDICAL PRINCIPLES AND PRACTICE, 1998, 7 (04) : 283 - 291
  • [9] A comparative study of Proximal Femoral Nail (PFN) versus Dynamic Condylar Screw (DCS) in management of unstable trochanteric fractures
    Jamil, Md Faraz
    Mohd, Julfiqar
    Abbas, Mazhar
    Siddiqui, Yasir Salam
    Khan, Mohammad Jesan
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2022, 12 (03): : 83 - 92
  • [10] Subtrochanteric Femoral Fractures Treated by Fixation with Dynamic Condylar Screw System
    Laghari, Muhammad Ayoub
    Makhdoom, Asadullah
    Pahore, Muhammad Khan
    Memon, Abbas
    Memon, Faheem Ahmed
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2011, 10 (03): : 134 - 137