Population Dose Volume Histograms: An Institutional Analysis of An Uniform Sample of IMRT Plans for Prostate Treatments

被引:0
|
作者
Neves-Junior, W.
Casagrande, T.
Alves, T.
Mancini, A.
Pelosi, E.
Haddad, C.
Silva, J.
机构
关键词
D O I
10.1118/1.3468554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-GG-T164
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Evaluating Head and Neck IMRT Plans with a Computational Tool for Spatial Dose-Volume Histograms
    Myint, K.
    Pyakuryal, A.
    Gopalakrishnan, M.
    Sathiaseelan, V.
    Mittal, B. B.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Method to account for dose fractionation in analysis of IMRT plans: Modified equivalent uniform dose
    Park, CS
    Kim, Y
    Lee, N
    Bucci, KM
    Quivey, JM
    Verhey, LJ
    Xia, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03): : 925 - 932
  • [3] OPTIMIZATION OF TREATMENT PLANS BASED ON DOSE VOLUME HISTOGRAMS
    LYMAN, JT
    WOLBARST, AB
    MEDICAL PHYSICS, 1985, 12 (04) : 523 - 523
  • [4] Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms
    Marrazzo, Livia
    Arilli, Chiara
    Pasler, Marlies
    Kusters, Martijn
    Canters, Richard
    Fedeli, Luca
    Calusi, Silvia
    Casati, Marta
    Talamonti, Cinzia
    Simontacchi, Gabriele
    Livi, Lorenzo
    Pallotta, Stefania
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (03) : 243 - 254
  • [5] Evaluation of Dose-Volume Variability and Parameters Between Prostate IMRT and VMAT Plans
    Chow, J.
    Jiang, R.
    Kiciak, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3550 - 3550
  • [6] Dose comparisons for conformal, IMRT and VMAT prostate plans
    Sale, Charlotte
    Moloney, Phillip
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (06) : 611 - 621
  • [7] EUD BASED IMRT FOR PROSTATE CANCER IN 174 PATIENTS - TOXIC ITIES AND CORRELATING DOSE-VOLUME-HISTOGRAMS
    Ganswindt, U.
    Nguyen, G.
    Horst, A.
    Frey, B.
    Soehn, M.
    Alber, M.
    Bamberg, M.
    Belka, C.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S324 - S324
  • [8] Is uniform target dose possible in IMRT plans in the head and neck?
    Vineberg, KA
    Eisbruch, A
    Coselmon, MM
    McShan, DL
    Kessler, ML
    Fraass, BA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05): : 1159 - 1172
  • [9] Quality of Prostate IMRT Plans Generated Using Biological versus Dose-Volume Constraints
    Semenenko, V. A.
    Chen, G-P
    Lawton, C. A.
    Li, X. A.
    MEDICAL PHYSICS, 2011, 38 (06) : 3638 - +
  • [10] Key Anatomical Factors Influencing OAR Dose-Volume Distribution in Prostate IMRT Plans
    Yuan, L.
    Ge, Y.
    Li, T.
    Zhu, X.
    Yin, F.
    Wu, Q.
    MEDICAL PHYSICS, 2011, 38 (06)