Surface strain-field determination of tympanic membrane using 3D-digital holographic interferometry

被引:14
|
作者
Hernandez-Montes, Maria del S. [1 ]
Mendoza Santoyo, Fernando [1 ]
Munoz, Silvino [1 ]
Perez, Carlos [1 ]
de la Torre, Manuel [1 ]
Flores, Mauricio [1 ]
Alvarez, Luis [2 ]
机构
[1] Ctr Invest Opt AC, CIO, Guanajuato 37150, Mexico
[2] Univ Nacl Autonoma Mexico, Mexico City 04510, DF, Mexico
关键词
Digital holographic interferometry; Nondestructive testing; Tissue characterization; Strain; Tympanic membrane; PULSED DIGITAL HOLOGRAPHY; LASER-DOPPLER VIBROMETER; HUMAN MIDDLE-EAR; MECHANICAL-PROPERTIES; TISSUE; CAT; ELASTOGRAPHY; DEFORMATION; VIBRATIONS; EARDRUM;
D O I
10.1016/j.optlaseng.2015.03.008
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to increase the understanding of soft tissues mechanical properties, 3D Digital Holographic Interferometry (3D-DHI) was used to quantify the strain-field on a cat tympanic membrane (TM) surface. The experiments were carried out applying a constant sound-stimuli pressure of 90 dB SPL (0.632 Pa) on the TM at 1.2 kHz. The technique allows the accurate acquisition of the micro-displacement data along the x, y and z directions, which is a must for a full characterization of the tissue mechanical behavior under load, and for the calculation of the strain-field in situ. The displacements repeatability in z direction shows a standard deviation of 0.062 mu m at 95% confidence level. In order to realize the full 3D characterization correctly the contour of the TM surface was measured employing the optically non-contact two-illumination positions contouring method. The x, y and z displacements combined with the TM contour data allow the evaluation its strain-field by spatially differentiating the u(m,n), v(m,n), and w(m,n) deformation components. The accurate and correct determination of the TM strain-field leads to describing its elasticity, which is an important parameter needed to improve ear biomechanics studies, audition processes and TM mobility in both experimental measurements and theoretical analysis of ear functionality and its modeling. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 50 条
  • [1] 3D displacement measurements of the tympanic membrane with digital holographic interferometry
    Munoz Solis, S.
    Mendoza Santoyo, F.
    del Socorro Hernandez-Montes, M.
    OPTICS EXPRESS, 2012, 20 (05): : 5613 - 5621
  • [2] Measurements of the tympanic membrane with digital holographic interferometry
    Munoz Solis, S.
    Mendoza Santoyo, F.
    del Socorro Hernandez-Montes, M.
    22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
  • [3] 3-D DIGITAL HOLOGRAPHIC INTERFEROMETRY AS A TOOL TO MEASURE THE TYMPANIC MEMBRANE MOTION
    del Socorro Hernandez-Montes, M.
    Munoz Solis, S.
    Mendoza Santoyo, F.
    SPECKLE 2012: V INTERNATIONAL CONFERENCE ON SPECKLE METROLOGY, 2012, 8413
  • [4] Study of Tympanic Membrane Displacements with Digital Holographic Interferometry
    del Socorro Hernandez-Montes, Maria
    Mendoza Santoyo, Fernando
    Munoz Solis, Silvino
    SPECKLE 2010: OPTICAL METROLOGY, 2010, 7387
  • [5] Digital holographic interferometry applied to the study of tympanic membrane displacements
    del Socorro Hernandez-Montes, Maria
    Mendoza Santoyo, Fernando
    Perez Lopez, Carlos
    Munoz Solis, Silvino
    Esquivel, Jesus
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (06) : 698 - 702
  • [6] Surface strain distribution on thin metallic plates using 3-D digital holographic interferometry
    De la Torre-Ibarra, Manuel
    Santoyo, Fernando Mendoza
    Perez-Lopez, Carlos
    Anaya, Tonatiuh Saucedo
    Aguayo, Daniel D.
    OPTICAL ENGINEERING, 2006, 45 (10)
  • [7] Strain determination in bone sections with simultaneous 3D digital holographic interferometry
    Sanchez Alvarez, Araceli
    De la Torre Ibarra, Manuel H.
    Mendoza Santoyo, Fernando
    Anaya, Tonatiuh-Saucedo
    OPTICS AND LASERS IN ENGINEERING, 2014, 57 : 101 - 108
  • [8] Measurement of strain distributions in mouse femora with 3D-digital speckle pattern interferometry
    Yanga, Lianxiang
    Zhang, Ping
    Liu, Sheng
    Samala, Praveen R.
    Su, Min
    Yokota, Hiroki
    OPTICS AND LASERS IN ENGINEERING, 2007, 45 (08) : 843 - 851
  • [9] Strain field measurements over 3000 °C using 3D-Digital image correlation
    Pan, Zhiwei
    Huang, Shenghong
    Su, Yong
    Qiao, Meixia
    Zhang, Qingchuan
    OPTICS AND LASERS IN ENGINEERING, 2020, 127
  • [10] Tympanic membrane contour measurement with two source positions in digital holographic interferometry
    Solis, Silvino M.
    Hernandez-Montes, Maria del S.
    Santoyo, Fernando M.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (12):