Screen-printed electrodes modified with functionalized mesoporous silica for voltammetric analysis of toxic metal ions

被引:62
|
作者
Yantasee, W [1 ]
Deibler, LA [1 ]
Fryxell, GE [1 ]
Timchalk, C [1 ]
Lin, YH [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国国家卫生研究院;
关键词
screen-printed carbon electrode; lead; mercury-free; adsorptive stripping voltammetry;
D O I
10.1016/j.elecom.2005.08.018
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Mercury-free sensors for lead (Pb2+) assay based on chemical modification of screen-printed carbon electrodes (SPCEs) with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) have been developed. The analysis of Pb using SPCEs-based adsorptive stripping voltarnmetry (AdSV) includes two steps. Pb2+ ions are firstly adsorbed on electrode surface in a Pb2+ solution (15 ml) during a preconcentration step, followed by a measurement step using one drop of acidic solution (50 mu l) as medium for stripping voltammetry. The preconcentration of Pb2+ at SAMMS-based sensors utilize the binding affinity of the acetamide phosphonic acid and Pb2+ which can be accomplished at open circuit potential without electrolyte and solution degassing. Due to the strong covalent bonding of the functional groups on mesoporous silica, the SAMMS-based sensors with a built-in three electrode system can be reused for tens of measurements with minimal degradation, enabling the establishment of the calibration curve and lowering the costs. Linear calibration curve was found in the range of 0 to at least 100 ppb Pb2+ after 5 min of preconcentration. The detection limit was calculated from 3S/N to be 0.91 ppb of Pb2+. Reproducibilty (%RSD) was found to be 5% for a single sensor (six measurements) and 10% for five sensors. The reproducibility can be improved through the precision of manufacturing of the sensors, in which SAMMS modification can be done in situ, increasing the user-friendliness of the sensors. Cadmium, lead, and copper can also be detected simultaneously at the SAMMS modified screen-printed sensors. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1170 / 1176
页数:7
相关论文
共 50 条
  • [1] Antimony nanomaterials modified screen-printed electrodes for the voltammetric determination of metal ions
    Tapia, Maria A.
    Perez-Rafols, Clara
    Pastika, Jan
    Gusmao, Rui
    Serrano, Nuria
    Sofer, Zdenek
    Diaz-Cruz, Jose Manuel
    ELECTROCHIMICA ACTA, 2022, 425
  • [2] Voltammetric analysis of europium at screen-printed electrodes modified with salicylamide self-assembled on mesoporous silica
    Yantasee, Wassana
    Fryxell, Glen E.
    Lin, Yuehe
    ANALYST, 2006, 131 (12) : 1342 - 1346
  • [3] Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
    Puy-Llovera, Jaume
    Perez-Rafols, Clara
    Serrano, Nutiria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 175 : 501 - 506
  • [4] A screen-printed voltammetric electronic tongue for the analysis of complex mixtures of metal ions
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Arino, Cristina
    Esteban, Miguel
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 250 : 393 - 401
  • [5] Stripping Voltammetric Measurement of Trace Metal Ions at Screen-printed Carbon and Carbon Paste Electrodes
    Somerset, Vernon
    Iwuoha, Emmanuel
    Hernandez, Lucas
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1279 - +
  • [6] Development of screen-printed carbon electrodes modified with functionalized mesoporous silica nanoparticles: Application to voltammetric stripping determination of Pb(II) in non-pretreated natural waters
    Sanchez, Alfredo
    Morante-Zarcero, Sonia
    Perez-Quintanilla, Damian
    Sierra, Isabel
    del Hierro, Isabel
    ELECTROCHIMICA ACTA, 2010, 55 (23) : 6983 - 6990
  • [7] Enhanced voltammetric determination of metal ions by using a bismuthene-modified screen-printed electrode
    Tapia, Maria A.
    Perez-Rafols, Clara
    Gusmao, Rui
    Serrano, Nuria
    Sofer, Zdenek
    Manuel Diaz-Cruz, Jose
    ELECTROCHIMICA ACTA, 2020, 362
  • [8] Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements
    Economou, Anastasios
    SENSORS, 2018, 18 (04)
  • [9] Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Arino, Cristina
    Esteban, Miquel
    TALANTA, 2016, 155 : 8 - 13
  • [10] Screen-Printed Electrodes for the Voltammetric Sensing of Benzotriazoles in Water
    Muschietti, Alessandra
    Serrano, Nuria
    Arino, Cristina
    Silvia Diaz-Cruz, M.
    Manuel Diaz-Cruz, Jose
    SENSORS, 2020, 20 (07)