Influence of Spectroscopic Techniques on the Estimation of the Degree of Conversion of Bulk-fill Composites

被引:16
|
作者
Bolanos-Carmona, V [1 ]
Benavides-Reyes, C. [2 ]
Gonzalez-Lopez, S. [2 ]
Gonzalez-Rodriguez, P. [2 ]
Alvarez-Lloret, P. [3 ]
机构
[1] Univ Granada, Fac Dent, Integrated Pediat Dent, Granada, Spain
[2] Univ Granada, Fac Dent, Dept Operat Dent, Granada, Spain
[3] Univ Oviedo, Fac Geol, Dept Geol, Oviedo, Spain
关键词
RESIN-BASED COMPOSITES; POLYMERIZATION SHRINKAGE; MECHANICAL-PROPERTIES; POST-POLYMERIZATION; MONOMER CONVERSION; LIGHT TRANSMISSION; DENTAL COMPOSITES; BIS-GMA; STRESS; RAMAN;
D O I
10.2341/18-095-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the degree of conversion (DC) of different flowable and sculptable bulk-fill composites (BFC), at 0- and 4-mm depths from the surface, by Fourier transform infrared (FTIR), attenuated total reflection FTIR (ATR-FTIR), and FT-Raman spectroscopic techniques. Methods and Materials: Six BFC were investigated, including three sculptable composites (Admira Fusion [Voco], Aura Bulk Fill [SDI], and X-tra Fill [Voco]) and three flowable composites (Venus Bulk Fill [Heraeus], Filtek [3M], and X-tra Base [Voco]). Three molds of each composite were light cured as specified by the manufacturer. For each mold, slices corresponding to 0-mm (surface) and 4-mm depth were analyzed by spectroscopic techniques: ATR-FTIR, FTIR, and FT-Raman. The spectra of uncured composite material were used as an analytical control for background subtraction of the treated composite. The area and amplitude of the reference peaks (1607 and 1637 cm(-1)) were obtained to calculate the DC percentage at 0- and 4-mm depth. A Kruskal-Wallis nonparametric test was used for materials, and paired comparisons were made using Mann-Whitney nonparametric test. Wilcoxon's rank test was used for comparison between spectroscopic methods and between 0- and 4-mm depth in each composite. Significance was accepted at p<0.05. Results: FTIR showed significantly lower DC values, both in areas and amplitudes of the peaks, when compared with the results reported by different BFC. Differences between the surface and 4-mm depth were detected more precisely by FT-Raman. ATR-FTIR obtained DC values significantly higher than those obtained by FTIR. Conclusions: The vibrational spectroscopy method significantly influenced DC measurements of the flowable and sculptable BFC explored.
引用
收藏
页码:92 / 103
页数:12
相关论文
共 50 条
  • [1] Measurements for restorative dentistry: shrinkage and conversion degree of bulk-fill composites
    Grassini, Sabrina
    Sebar, Leila E. S.
    Baldi, Andrea
    Comba, Allegra
    Angelini, Emma
    Berutti, Elio
    2022 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA 2022), 2022,
  • [2] Degree of Conversion and Polymerization Shrinkage of Bulk-Fill Resin-Based Composites
    Yu, P.
    Yap, A. U. J.
    Wang, X. Y.
    OPERATIVE DENTISTRY, 2017, 42 (01) : 82 - 89
  • [3] Raman Spectroscopic Assessment of Degree of Conversion of Bulk-Fill Resin Composites - Changes at 24 Hours Post Cure
    Par, M.
    Gamulin, O.
    Marovic, D.
    Klaric, E.
    Tarle, Z.
    OPERATIVE DENTISTRY, 2015, 40 (03) : E92 - E101
  • [4] Comparative analysis of conversion and crosslinking degree in bulk-fill, monochromatic, and ORMOCER composites
    Gonsalves, Flavia
    de Araujo, Maria Aparecida Carvalho
    Cosimato, Paulo Luis
    Sanches, Luciana Katty Figueiredo
    Silva, Larissa Tavares
    Roschel, Julia Noborikawa
    Pimentel, Angelica Castro
    Boaro, Leticia Cidreira
    JOURNAL OF DENTISTRY, 2025, 154
  • [5] Degree of conversion and polymerization shrinkage of low shrinkage bulk-fill resin composites
    Salem, Haidy N.
    Hefnawy, Sherif M.
    Nagi, Shaymaa M.
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 465 - 470
  • [6] Long Term Degree of Conversion of two Bulk-Fill
    Par, Matej
    Lapas-Barisic, Matea
    Gamulin, Ozren
    Panduric, Vlatko
    Spanovic, Nika
    Tarle, Zrinka
    ACTA STOMATOLOGICA CROATICA, 2016, 50 (04) : 292 - 300
  • [7] Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites
    Z. Tarle
    T. Attin
    D. Marovic
    L. Andermatt
    M. Ristic
    T. T. Tauböck
    Clinical Oral Investigations, 2015, 19 : 831 - 840
  • [8] Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites
    Tarle, Z.
    Attin, T.
    Marovic, D.
    Andermatt, L.
    Ristic, M.
    Tauboeck, T. T.
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (04) : 831 - 840
  • [9] Effect of thickness on the degree of conversion, monomer elution, depth of cure and cytotoxicity of bulk-fill composites
    Yildirim, Zehra Susgun
    Eyiler, Ersan
    Kurklu, Zeliha G. Bek
    JOURNAL OF ORAL SCIENCE, 2023, 65 (02) : 121 - 126
  • [10] A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity
    Zuniga Cisneros, Alejandra
    Sojo Armas, Alessandra
    BRAZILIAN ORAL RESEARCH, 2019, 33