Effects of Inlet Geometry on the Pressure Drop and Collection Efficiency of Tangential Inlet Cyclones

被引:0
|
作者
Teke, Mehmet [1 ]
Karagoz, Irfan [1 ]
机构
[1] Uludag Univ, FIGES AS, Bursa, Turkey
关键词
PERFORMANCE; SAMPLERS; FLOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This work presents a computational fluid dynamics simulation to investigate the effects of inlet geometry on the pressure drop and particle collection efficiency of a tangential inlet cyclone. Three-dimensional, steady governing equations for the incompressible, turbulent flow inside a tangential inlet cyclone are solved numerically under certain boundary conditions. The continuous gas flow is predicted by solving Navier-Stokes equations using the differential RSM turbulence model. The second phase is modeled based on a Lagrangian approach. The commercial CFD code Fluent was used for numerical analysis. Computational results compared experimental data available in the literature for validation. Various cyclones, each has different geometrical ratio of inlet section, studied in this paper Detail analyses of the effects of inlet geometry on the flow behavior, pressure drop and collection efficiency were given.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 50 条
  • [1] Efficiency and pressure drop of cyclones across a range of inlet velocities
    Faulkner, WB
    Shaw, BW
    APPLIED ENGINEERING IN AGRICULTURE, 2006, 22 (01) : 155 - 161
  • [2] Flow in the inlet region in tangential inlet cyclones
    Peng, WM
    Boot, PJAJ
    Hoffmann, AC
    Dries, HWA
    Kater, J
    Ekker, A
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (23) : 5649 - 5655
  • [3] Modelling of the pressure drop in tangential inlet cyclone separators
    Karagoz, I
    Avci, A
    AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (09) : 857 - 865
  • [4] INLET PRESSURE EFFECTS ON THE COLLECTION EFFICIENCY OF DIFFUSION SCRUBBERS
    DASGUPTA, PK
    LINDGREN, PF
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (07) : 895 - 897
  • [5] Development of a cyclone separator with high efficiency and low pressure drop in axial inlet cyclones
    Xiong, Zhiyi
    Ji, Zhongli
    Wu, Xiaolin
    POWDER TECHNOLOGY, 2014, 253 : 644 - 649
  • [6] EXPERIMENTAL INVESTIGATION OF EFFECT OF VENT PIPE DIAMETER CHANGING IN TANGENTIAL INLET REVERSE FLOW CYCLONES ON PRESSURE DROP
    Ficici, Ferit
    Ari, Vedat
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2008, 14 (02): : 205 - 211
  • [7] An experimental investigation on pressure drop and collection efficiency of cyclone separator with different inlet vanes
    Zhao, F.
    Chen, Y. X.
    Liu, W. H.
    Xu, D. L.
    Proceedings of the 6th International Symposium on Cement & Concrete and CANMET/ACI International Symposium on Concrete Technology for Sustainable Development, Vols 1 and 2, 2006, : 145 - 150
  • [8] Effects of the inlet angle on the collection efficiency of a cyclone with helical-roof inlet
    Misiulia, Dzmitry
    Andersson, Anders Gustav
    Lundstrom, T. Staffan
    POWDER TECHNOLOGY, 2017, 305 : 48 - 55
  • [9] A study of the effect of high inlet solids loading on a cyclone separator pressure drop and collection efficiency
    Fassani, FL
    Goldstein, L
    POWDER TECHNOLOGY, 2000, 107 (1-2) : 60 - 65
  • [10] Enhancing the efficiency of two-stage cyclones without increasing pressure drop by optimizing inlet and outlet dimensions
    He, Jiongjie
    Zhu, Zhenxing
    Niu, Hongbin
    Tian, Zhihong
    Yang, Jingxuan
    Sun, Guogang
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 102 (12): : 4371 - 4385