Experimental study of mixed convection heat transfer in a vertical channel with a one-sided semicylindrical constriction with prescribed heat flux

被引:5
|
作者
Rosas, I. Y. [1 ]
Trevino, C. [2 ]
Martinez-Suastegui, L. [1 ,3 ]
机构
[1] Inst Politecn Nacl, ESIME Azcapotzalco, Ave Granjas 682, Mexico City 02250, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Ciencias, UMDI, Sisal, Yucatan, Mexico
[3] Univ Autanoma Ciudad Mexico, Colegio Ciencia & Tecnol, Mexico City 09940, DF, Mexico
关键词
Wall-mounted hemisphere; Convex curvature; Curved step constriction; Flow separation; Bounded flow; SELF-SUSTAINED OSCILLATIONS; VORTEX-INDUCED VIBRATIONS; TRANSFER ENHANCEMENT; FORCED-CONVECTION; NATURAL-CONVECTION; RECTANGULAR CHANNEL; MOUNTED OBSTACLES; SURFACE RADIATION; GROOVED CHANNELS; SUDDEN EXPANSION;
D O I
10.1016/j.ijheatfluidflow.2017.08.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study of mixed convection heat transfer is carried out in a vertical channel with a one-sided semicylindrical constriction with prescribed heat flux while the other bounding walls are insulated and adiabatic. The semicylinder is placed horizontally at the mid-plane with a blockage ratio (BR, ratio between the semicylinder diameter and the thickness of the rectangular section) of 0.3 and a semicylinder aspect ratio (AR, ratio between the length and diameter of the semicylinder) of 6. The effect of opposing buoyancy on the flow and thermal behavior is analyzed for fixed Prandtl number of Pr = 7, Reynolds number based on semicylinder diameter of 20 <= Re <= 350 and buoyancy strength or modified Richardson number, Ri* = Gr*/Re-2, from 20 to 350. For relatively large values of Ri*, flow visualization images and thermal analysis confirm the presence of a complex three-dimensional (3D) two-vortex structure with two recirculation bubbles present at the forebody and rear of the semicylinder. Surface temperature distributions and averaged Nusselt number at different Reynolds and modified Richardson numbers have been obtained. The results show that variation of the local temperature distributions with angular position and spanwise location become evident, and their relation to the presence of a complex 3D vortex structure that develops close to the semicylindrical constriction has been studied and discussed in detail. Moreover, empirical correlations for the overall Nusselt number are obtained using both Re and Gr* and Re and Ri* as the controlling parameters. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [1] Opposing Flow Turbulent Mixed-Convection Heat Transfer in a Vertical Flat Channel with One-Sided Heating
    Poskas, Robertas
    Poskas, Povilas
    Kolesnikovas, Jokubas
    HEAT TRANSFER RESEARCH, 2006, 37 (01) : 21 - 34
  • [2] Experimental study of buoyancy and inclination effects on transient mixed convection heat transfer in a channel with two symmetric open cubic cavities with prescribed heat flux
    Cardenas, V
    Trevino, C.
    Rosas, I. Y.
    Martinez-Suastegui, L.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 140 : 71 - 86
  • [3] EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN MHD CHANNEL
    YANG, HK
    YU, CP
    AIAA JOURNAL, 1974, 12 (12) : 1740 - 1743
  • [4] Experimental and numerical study of mixed convection heat and mass transfer in a vertical channel with film evaporation
    Cherif, A. S.
    Kassim, M. A.
    Benhamou, B.
    Harmand, S.
    Corriou, J. P.
    Ben Jabrallah, S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2011, 50 (06) : 942 - 953
  • [5] The Reynolds analogy for the mixed convection over a vertical surface with prescribed heat flux
    E. Magyari
    I. Pop
    Zeitschrift für angewandte Mathematik und Physik, 2009, 60 : 324 - 333
  • [6] The Reynolds analogy for the mixed convection over a vertical surface with prescribed heat flux
    Magyari, E.
    Pop, I.
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 2009, 60 (02): : 324 - 333
  • [7] Mixed convection heat transfer in a vertical channel with a moving plate
    Andreozzi, A
    Bianco, N
    Manca, O
    Naso, V
    COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS XII, 2005, 41 : 695 - 704
  • [8] Experimental study of mixed convection heat transfer in vertical helically coiled tube heat exchangers
    Ghorbani, N.
    Taherian, H.
    Gorji, M.
    Mirgolbabaei, H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (07) : 900 - 905
  • [9] Experimental Investigation of Opposing Turbulent Mixed-Convection Heat Transfer in an Inclined Flat Channel with One-Sided Heating. 2. Heat Transfer Variation along Inclined Flat Channels
    Poskas, Robertas
    Poskas, Povilas
    Sinkunas, Stasys
    HEAT TRANSFER RESEARCH, 2008, 39 (08) : 731 - 738
  • [10] G-jitter fully developed heat transfer by mixed convection flow in a vertical channel with constant heat flux
    Amin, Wan Nor Zaleha
    Mohammad, Ahmad Qushairi
    Abdulhameed, Mohammed
    Shafie, Sharidan
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2020, 16 (01): : 105 - 108