Performance of Dexcom G5 and FreeStyle Libre sensors tested simultaneously in people with type 1 or 2 diabetes and advanced chronic kidney disease

被引:7
|
作者
Olafsdottir, Arndis Finna [1 ,2 ]
Andelin, Mervi [1 ]
Saeed, Aso [3 ]
Sofizadeh, Sheyda [1 ]
Hamoodi, Hussein [4 ]
Jansson, Per-Anders [5 ]
Lind, Marcus [1 ,2 ]
机构
[1] NU Hosp Grp, Dept Med, Fjallvagen 9, Uddevalla, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med, Gothenburg, Sweden
[3] Gothenburg Univ, Sahlgrenska Acad, Inst Internal Med, Dept Nephrol, Gothenburg, Sweden
[4] Statistiska Konsultgruppen, Gothenburg, Sweden
[5] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Wallenberg Lab,Dept Mol & Clin Med, Gothenburg, Sweden
关键词
Type; 1; diabetes; 2; Chronic kidney disease; Continuous glucose monitoring; Accuracy; Mean absolute relative difference; TREATMENT EXPERIENCE; CLINICAL-TRIAL; GLUCOSE; ACCURACY; SYSTEM;
D O I
10.12998/wjcc.v10.i22.7794
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Advanced chronic kidney disease (CKD) is a common complication for people with type 1 and 2 diabetes and can often lead to glucose instability. Continuous glucose monitoring (CGM) helps users monitor and stabilize their glucose levels. To date, CGM and intermittent scanning CGM are only approved for people with diabetes but not for those with advanced CKD. AIM To compare the performance of Dexcom G5 and FreeStyle Libre sensors in adults with type 1 or 2 diabetes and advanced CKD. METHODS This was a non-randomized clinical trial that took place in two outpatient clinics in western Sweden. All patients with type 1 or 2 diabetes and an estimated glomerular filtration rate (eGFR) of < 30 mL/min per 1.73 m(2) were invited to participate. Forty patients (full analysis set = 33) carried the Dexcom G5 sensor for 7 d and FreeStyle Libre sensor for 14 d simultaneously. For referencing capillary blood glucose (SMBG) was measured with a high accuracy glucose meter (HemoCue (R)) during the study period. At the end of the study, all patients were asked to answer a questionnaire on their experience using the sensors. RESULTS The mean age was 64.1 (range 41-77) years, hemoglobin A1c was 7.0% [standard deviation (SD) 3.2], and diabetes duration was 28.5 (SD 14.7) years. A total of 27.5% of the study population was on hemodialysis and 22.5% on peritoneal dialysis. The mean absolute relative difference for Dexcom G5 vs SMBG was significantly lower than that for FreeStyle Libre vs SMBG [15.2% (SD 12.2) vs 20.9% (SD 8.6)], with a mean difference of 5.72 [95% confidence interval (CI): 2.11-9.32; P = 0.0036]. The mean absolute difference was also significantly lower for Dexcom G5 than for FreeStyle Libre, 1.21 mmol/L (SD 0.78) and 1.76 mmol/L (SD 0.78), with a mean diffrenec of 0.55 (95%CI: 0.27-0.83; P = 0.0004).The mean difference (MD) was -0.107 mmol/L and -1.10 mmol/L (P = 0.0002), respectively. In all, 66% of FreeStyle Libre values were in the no risk zone on the surveillance error grid compared to 82% of Dexcom G5 values. CONCLUSION Dexcom G5 produces more accurate sensor values than FreeStyle Libre in people with diabetes and advanced CKD and is likely safe to be used by those with advanced CKD.
引用
收藏
页码:7794 / 7807
页数:14
相关论文
共 50 条
  • [1] Performance of Dexcom G5 and FreeStyle Libre sensors tested simultaneously in people with type 1 or 2 diabetes and advanced chronic kidney disease
    Arndís Finna ólafsdóttir
    Mervi Andelin
    Aso Saeed
    Sheyda Sofizadeh
    Hussein Hamoodi
    Per-Anders Jansson
    Marcus Lind
    World Journal of Clinical Cases, 2022, (22) : 7794 - 7807
  • [2] Omnipod 5 outcomes comparing Dexcom G6 and Freestyle Libre 2 plus users in adults with type 1 diabetes
    Stimson, Roland H.
    Dover, Anna R.
    Lyall, Marcus J.
    Kyle, Catriona J.
    Wright, Rohana J.
    McRobert, Gayle
    Strachan, Mark W. J.
    Gibb, Fraser W.
    DIABETIC MEDICINE, 2025, 42 (03)
  • [3] A Three-Way Accuracy Comparison of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense CGM Devices in an Outpatient Study of Subjects with Type 1 Diabetes
    Jafri, Rabab Z.
    Balliro, Courtney A.
    El-Khatib, Firas
    Maheno, Michele
    Hillard, Mallory A.
    O'Donovan, Alexander J.
    Selagamsetty, Rajendranath
    Zheng, Hui
    Damiano, Edward
    Russell, Steven J.
    DIABETES, 2018, 67
  • [4] A Comparison of Continuous Glucose Monitors in Reducing MC in Type 1 and Type 2 Diabetes: FreeStyle Libre and Dexcom
    Miller, Eden
    Joseph, Jennifer
    Reyes, Ignacio J.
    Nabutovsky, Yelena
    Virdi, Naunihal
    Hirsch, Irl B.
    DIABETES, 2021, 70
  • [5] A Three-Way Accuracy Comparison of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense Continuous Glucose Monitoring Devices in a Home-Use Study of Subjects with Type 1 Diabetes
    Jafri, Rabab Z.
    Balliro, Courtney A.
    El-Khatib, Firas
    Maheno, Michele M.
    Hillard, Mallory A.
    O'Donovan, Alexander
    Selagamsetty, Rajendranath
    Zheng, Hui
    Damiano, Edward R.
    Russell, Steven J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 846 - 852
  • [6] ACCURACY AND RELIABILITY OF TWO GLUCOSE MONITORING SYSTEMS TESTED SIMULTANEOUSLY IN AMBULATORY PATIENTS WITH TYPE 1 OR 2 DIABETES AND ADVANCED CHRONIC KIDNEY DISEASE.
    Olafsdottir, A. F.
    Andelin, M.
    Saeed, A.
    Sofizadeh, S.
    Jansson, P. -A.
    Lind, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A122 - A123
  • [7] Acute Diabetes Events and All Cause Hospitalizations among Continuous Glucose Monitoring Device Recipients with Type 1 and Type 2 Diabetes: A Comparison of FreeStyle Libre and Dexcom
    Hirsch, Irl B.
    Roberts, Gregory J.
    Joseph, Jennifer
    Nabutovsky, Yelena
    Virdi, Naunihal
    Miller, Eden
    DIABETES, 2021, 70
  • [8] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [9] Hospitalisations for acute complications before and after FreeStyle Libre® system initiation in people with type 1 and type 2 diabetes in France
    Guerci, B.
    Roussel, R.
    Vicaut, E.
    De Pouvourville, G.
    Detournay, B.
    Emery, C.
    Levrat-Guillen, F.
    Riveline, J. -P.
    DIABETOLOGIA, 2020, 63 (SUPPL 1) : S340 - S340
  • [10] A CLINICAL TRIAL OF THE ACCURACY AND TREATMENT EXPERIENCE OF THE DEXCOM G4 SENSOR AND ENLITE SENSOR TESTED SIMULTANEOUSLY IN AMBULATORY PATIENTS WITH TYPE 1 DIABETES
    Matuleviciene, V.
    Joseph, J.
    Andelin, M.
    Hirsch, I. B.
    Attvall, S.
    Dahlqvist, S.
    Klonoff, D.
    Haraldsson, B.
    Lind, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A84 - A84