Assessment of Low-Frequency Magnetic Fields Emitted by DC Fast Charging Columns

被引:5
|
作者
Trentadue, Germana [1 ]
Pinto, Rosanna [2 ]
Salvetti, Marco [1 ]
Zanni, Marco [1 ]
Pliakostathis, Konstantinos [1 ]
Scholz, Harald [1 ]
Martini, Giorgio [1 ]
机构
[1] European Commiss, JRC, Via E Fermi 2749, I-21027 Ispra, Italy
[2] ENEA Italian Natl Agcy New Technol Energy & Susta, RC Casaccia, Rome, Italy
关键词
DC charging; fast charging; human electromagnetic field exposure; magnetic flux density; e-mobility; EXPOSURE; GASOLINE;
D O I
10.1002/bem.22254
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The expected imminent widespread use of electromobility in transport systems draws attention to the possible effects of human exposure to magnetic fields generated inside electric vehicles and during their recharge. The current trend is to increase the capacity of the battery inside the vehicles to extend the available driving range and to increase the power of recharging columns to reduce the time required for a full recharge. This leads to higher currents and potentially stronger magnetic fields. The Interoperability Center of the Joint Research Center started an experimental activity focused on the assessment of low-frequency magnetic fields emitted by five fast-charging devices available on the market in recharge and standby conditions. The aim of this study was to contribute to the development of a standard measurement procedure for the assessment of magnetic fields emitted by direct current charging columns. The spectrum and amplitudes of the magnetic field, as well as exposure indices according to guidelines for the general public and occupational exposure, were recorded by means of a magnetic field probe analyzer. The worst-case scenario for instantaneous physical direct and indirect effects was identified. Measurements within the frequency range of 25 Hz-2 kHz revealed localized magnetic flux density peaks above 100 mu T at the 50 Hz frequency in three out of five chargers, registered in close proximity during the recharge. Beyond this distance, exposure indices were recorded showing values below 50% of reference levels. Bioelectromagnetics. (c) 2020 Bioelectromagnetics Society
引用
收藏
页码:308 / 317
页数:10
相关论文
共 50 条
  • [1] Low Frequency Magnetic Fields Emitted by High-Power Charging Systems
    Trentadue, Germana
    Pinto, Rosanna
    Zanni, Marco
    Scholz, Harald
    Pliakostathis, Konstantinos
    Martini, Giorgio
    ENERGIES, 2020, 13 (07)
  • [2] Measurement of low-frequency magnetic fields
    Wolfmayr, Holger
    Ziemann, Peter
    Technische Sicherheit, 2017, 7 (11-12): : 54 - 58
  • [3] Low-frequency electrical and magnetic fields
    Angerer, Manfred
    Eisenbahningenieur, 1997, 48 (09): : 37 - 40
  • [4] EDDY-CURRENT SENSOR FOR DC AND LOW-FREQUENCY MAGNETIC-FIELDS
    KAPLAN, BZ
    RABINOVICI, R
    PROCEEDINGS OF THE IEEE, 1985, 73 (06) : 1147 - 1148
  • [5] Numerical assessment of low-frequency dosimetry from sampled magnetic fields
    Freschi, Fabio
    Giaccone, Luca
    Cirimele, Vincenzo
    Canova, Aldo
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [6] VERY-LOW-FREQUENCY AND LOW-FREQUENCY ELECTRIC AND MAGNETIC FIELDS ASSOCIATED WITH ELECTRIC SHUTTLE BUS WIRELESS CHARGING
    Tell, R. A.
    Kavet, Robert
    Bailey, J. R.
    Halliwell, John
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 123 - 134
  • [7] DC AND LOW-FREQUENCY MAGNETIC MEASURING TECHNIQUES
    FLANDERS, PJ
    GRAHAM, CD
    REPORTS ON PROGRESS IN PHYSICS, 1993, 56 (03) : 431 - 492
  • [8] Low-frequency flux noise in YBCO dc SQUIDs cooled in static magnetic fields
    Department of Physics, Technical University of Denmark, DK-2800 Lyngby, Denmark
    不详
    不详
    Supercond Sci Technol, 11 (798-801):
  • [9] Low-frequency flux noise in YBCO dc SQUIDs cooled in static magnetic fields
    Sager, MP
    Petersen, PRE
    Holst, T
    Shen, YQ
    Hansen, JB
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1999, 12 (11): : 798 - 801
  • [10] Review of Russian literature on biological action of DC and low-frequency AC magnetic fields
    Zhadin, MN
    BIOELECTROMAGNETICS, 2001, 22 (01) : 27 - 45