First step toward a synthetic diagnostic for magnetic fluctuation measurements using cross-polarization scattering on DIII-D

被引:4
|
作者
Wang, G. [1 ]
Rhodes, T. L. [1 ]
Crocker, N. A. [1 ]
Peebles, W. A. [1 ]
Barada, K. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
MICROWAVE-SCATTERING; PLASMA; DENSITY; WAVES;
D O I
10.1063/1.5036791
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cross-polarization scattering (CPS) provides localized magnetic fluctuation ((B) over tilde) measurements in fusion plasmas based on the process where (B) over tilde scatters electromagnetic radiation into the orthogonal polarization. The CPS system on DIII-D utilizes the probe beam of a Doppler backscattering (DBS) diagnostic combined with a cross-view CPS receiver system, which allows simultaneous density and (B) over tilde measurements with good spatial and wavenumber coverage. The interpretation of the signals is challenging due to the complex plasma propagation of the DBS probe beam and CPS receive beams. A synthetic diagnostic for CPS is therefore essential to interpret data and perform detailed validation tests of non-linear turbulence simulations. This work reports a first step toward a synthetic diagnostic for CPS utilizing GENRAY, a 3-D ray tracing code, to simulate the propagation of the probe and scattered rays. The local (B) over tilde wavenumber is calculated from the local O-and X-mode wavenumbers using the wave vector matching scattering condition. The CPS wavenumber values and spatial locations are determined by a complex consideration that includes the local density and (B) over tilde level, receive antenna pattern and orientation, scattering volume, wavenumber values detected at the various scattering centers, and alignment of the magnetic wave vector with the plane perpendicular to the magnetic field. The issue of a spurious CPS signal due to polarization mismatches for launch and receive is also discussed. It is suggested that simultaneous O-and X-mode DBS measurements should be utilized for better understanding of the CPS signal contamination when the cutoff locations for both polarizations are close. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] Measurement of local, internal magnetic fluctuations via cross-polarization scattering in the DIII-D tokamak
    Barada, K.
    Rhodes, T. L.
    Crocker, N. A.
    Peebles, W. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [2] Development of a cross-polarization scattering system for the measurement of internal magnetic fluctuations in the DIII-D tokamak
    Rhodes, T. L.
    Peebles, W. A.
    Crocker, N. A.
    Nguyen, X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [3] Optimized quasi-optical cross-polarization scattering system for the measurement of magnetic turbulence on the DIII-D tokamak
    Rhodes, T. L.
    Lantsov, R.
    Wang, G.
    Ellis, R.
    Peebles, W. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [4] Simultaneous measurement of magnetic and density fluctuations via cross-polarization scattering and Doppler backscattering on the DIII-D tokamak
    Rhodes, T. L.
    Barada, K.
    Peebles, W. A.
    Crocker, N. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [5] First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D
    Gage, K. R.
    Du, X. D.
    Heidbrink, W. W.
    Gonzalez-Martin, J.
    Liu, D.
    Brown, A. C.
    NUCLEAR FUSION, 2025, 65 (02)
  • [6] Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D
    Chen, J.
    Ding, W. X.
    Brower, D. L.
    Finkenthal, D.
    Muscatello, C.
    Taussig, D.
    Boivin, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [7] FLUCTUATION MEASUREMENTS IN THE DIII-D AND TEXT TOKAMAKS VIA COLLECTIVE SCATTERING AND REFLECTOMETRY
    PEEBLES, WA
    BAANG, S
    BROWER, DL
    BURRELL, K
    DOYLE, EJ
    GROEBNER, RJ
    LEHECKA, T
    LUHMANN, NC
    MATSUMOTO, H
    PHILIPONA, R
    RETTIG, C
    RHODES, TL
    YU, CX
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (11): : 3509 - 3519
  • [8] FLUCTUATION MEASUREMENTS IN THE DIII-D AND TEXT TOKAMAKS VIA COLLECTIVE SCATTERING AND REFLECTOMETRY
    PEEBLES, WA
    BAANG, S
    BROWER, DL
    BURRELL, K
    DOYLE, EJ
    GROEBNER, RJ
    LEHECKA, T
    LUHMANN, NC
    MATSUMOTO, H
    PHILIPONA, R
    RETTIG, C
    RHODES, TL
    YU, CX
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2905 - 2905
  • [9] EDGE DENSITY FLUCTUATION DIAGNOSTIC FOR DIII-D USING LITHIUM BEAMS
    THOMAS, DM
    HYATT, AW
    THOMAS, MP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 3040 - 3042
  • [10] An upgrade of the magnetic diagnostic system of the DIII-D tokamak for non-axisymmetric measurements
    King, J. D.
    Strait, E. J.
    Boivin, R. L.
    Taussig, D.
    Watkins, M. G.
    Hanson, J. M.
    Logan, N. C.
    Paz-Soldan, C.
    Pace, D. C.
    Shiraki, D.
    Lanctot, M. J.
    La Haye, R. J.
    Lao, L. L.
    Battaglia, D. J.
    Sontag, A. C.
    Haskey, S. R.
    Bak, J. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08):