An Algorithm for Evaluating the ECG Signal Quality in 12 Lead ECG Monitoring System

被引:0
|
作者
Zhang, Yue [1 ]
Hou, Zhongjie [1 ]
机构
[1] Tsinghua Univ, Grad Sch Shenzhen, Lab Embedded Syst & Technol, Shenzhen, Peoples R China
关键词
ECG signal quality evaluation; lead-off detection; heart rate; spectral distribution ratio; neural network; 12-lead ECG;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
ECG signal quality is of great importance to real-time electrocardiogram(ECG) monitoring system. The paper introduces a new algorithm to evaluate the ECG signal quality. This algorithm is based on three features: heart rate score, spectral distribution ratio, and the variance between 12-lead ECG data. The result show that the proposed algorithm has a high Sensitivity of 95%, Specificity of 86.7%, and the Accuracy is 93.1%. The new algorithm is fast, accurate and reliable, showing strong potential to be applied in real-time ECG monitoring system.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [1] Scoring System for 12 Lead ECG Quality Assessment
    Odstrcilik, Tadeas
    Kuzilek, Jakub
    Chudacek, Vaclav
    Lhotska, Lenka
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 501 - 503
  • [2] ECG Signal Quality Assessments of Real-Time Single-Lead Wearable SmartPatch and 12-Lead ECG
    Im, Sung I.
    Hyun, B. A. E. Su
    Cho, Sung Phil
    CIRCULATION, 2023, 148
  • [3] A real-time quality monitoring system for optimal recording of 12-lead resting ECG
    Jekova, Irena
    Krasteva, Vessela
    Leber, Remo
    Schmid, Ramun
    Twerenbold, Raphael
    Reichlin, Tobias
    Mueller, Christian
    Abaecherli, Roger
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 34 : 126 - 133
  • [4] Robust Signal Synthesis of the 12-Lead ECG using 3-Lead Wireless ECG Systems
    Hsu, Chih-Hao
    Wu, Sau-Hsuan
    2014 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2014, : 3517 - 3522
  • [5] PORTABLE, REAL-TIME, 12-LEAD ECG MONITORING SYSTEM
    Tseng, Yi-Li
    Shi, Yo-Zong
    Jaw, Fu-Shan
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (04) : 305 - 312
  • [6] Design of Digital Signal Filtering Algorithm Based on Bluetooth ECG Monitoring System
    Wang, Xiaoni
    PROCEEDINGS OF 2015 6TH IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND SERVICE SCIENCE, 2015, : 578 - 581
  • [7] A new method-for evaluating ECG signal quality for multi-lead arrhythmia analysis
    Wang, JY
    COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 : 85 - 88
  • [8] ECG Monitoring in an Airplane Seat: Appraising the Signal Quality
    Schumm, Johannes
    Arnrich, Bert
    Troester, Gerhard
    IEEE PERVASIVE COMPUTING, 2012, 11 (04) : 28 - 34
  • [9] Automatic Quality Estimation of 12-lead ECG for Remote Healthcare Monitoring Systems
    Prabhakararao, Eedara
    Dandapat, Samarendra
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 554 - 559
  • [10] Quality of ECG monitoring with a miniature ECG recorder
    Janata, Andreas
    Lemmert, Miguel E.
    Russell, James K.
    Gehman, Stacy
    Fleischhackl, Roman
    Robak, Oliver
    Pernicka, Elisabeth
    Sterz, Fritz
    Gorgels, Anton P. M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (06): : 676 - 684