Microshear Bond Strength of Self-etching Systems Associated with a Hydrophobic Resin Layer

被引:7
|
作者
De Vito Moraes, Andre Guaraci
Francci, Carlos [1 ]
Carvalho, Ceci Nunes [2 ]
Soares, Silvio Peixoto
Braga, Roberto Ruggiero
机构
[1] Univ Sao Paulo, Fac Dent, Dept Dent Mat, BR-05508000 Sao Paulo, Brazil
[2] Univ Sao Paulo, Dept Dent, BR-05508000 Sao Paulo, Brazil
来源
JOURNAL OF ADHESIVE DENTISTRY | 2011年 / 13卷 / 04期
基金
巴西圣保罗研究基金会;
关键词
microshear bond strength; adhesive system; hydrophobic adhesive; dentin; ONE-STEP; CLINICAL EFFECTIVENESS; SINGLE-STEP; DENTIN; ADHESIVES; PERFORMANCE; PENETRATION; BOTTLE; WATER;
D O I
10.3290/j.jad.a19474
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers' instructions, associated or not with a hydrophobic layer of unfilled resin. Materials and Methods: Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, lvoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37 C for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey's post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. Results: The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 +/- 7.9; AdheSE: 14.5 +/- 7.1; Xeno III: 12.8 +/- 7.7; I Bond: 9.5 +/- 5.8; Bond Force: 17.5 +/- 4.1; Futurabond: 7.7 +/- 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 +/- 4.9; AdheSE 1.6 +/- 1.6; Xeno III: 9.0 +/- 3.8; I Bond: 3.0 +/- 1.5; Bond Force: 14 +/- 3.9; Futurabond: 8.8 +/- 3.8). Failure mode was predominantly adhesive. Conclusion: The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [1] Microtensile dentin bond strength of self-etching resins: Effect of a hydrophobic layer
    Brackett, WW
    Ito, S
    Tay, FR
    Haisch, LD
    Pashley, DH
    OPERATIVE DENTISTRY, 2005, 30 (06) : 733 - 738
  • [2] Microshear bond strength of self-etching adhesives to laser treated enamel.
    Ajlouni, A
    Cobb, D
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A160 - A160
  • [3] Effectiveness of self-etching bonding systems on dentin after radiotherapy: perspectives on microtensile and microshear bond strength
    Santin, Daniella Cristo
    de Souza, Isabella Dorigheto
    Rodrigues, Ana Carolina Cunha
    Costa, Mylena Proenca
    da Silva, Thalyta Khetly Cardoso
    Giacomini, Marina Ciccone
    Santos, Paulo Sergio da Silva
    Wang, Linda
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (11)
  • [4] Effect of a bonding resin layer associated with a self-etching adhesive system on the bond strength of indirect restorations
    Castro, Carolina Guimaraes
    Freitas Santos Filho, Paulo Cesar
    da Mota, Aderito Soares
    Campos, Roberto Elias
    Soares, Carlos Jose
    JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (02) : 94 - 98
  • [5] Microshear Bond Strength of Self-etching Bonding Systems to Ultrasound Diamond Bur-prepared Dentin
    Borges, Alessandra Buehler
    da Silva, Melissa Aline
    Souto Borges, Alexandre Luiz
    Werkman, Cristina
    Gomes Torres, Carlos Rocha
    Pucci, Cesar Rogerio
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (05): : 433 - 438
  • [6] Effect of saliva contamination on the microshear bond strength of one-step self-etching adhesive systems to dentin
    Yoo, HM
    Oh, TS
    Pereira, PNR
    OPERATIVE DENTISTRY, 2006, 31 (01) : 127 - 134
  • [7] BOND STRENGTH DURABILITY OF SELF-ETCHING ADHESIVES AND RESIN CEMENTS TO DENTIN
    Lima Chaves, Carolina de Andrade
    de Melo, Renata Marques
    Passos, Sheila Pestana
    Camargo, Fernanda Pelogia
    Bottino, Marco Antonio
    Balducci, Ivan
    JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (03) : 155 - 160
  • [8] Influence of Collagen Removal on the Bond Strength of Self-Etching Systems
    Braz, Rodivan
    Campos, Gheisa Bezerra
    Martins, Mariangela da S.
    Arruda Meira Ribeiro, Ana Isabella
    Tenroio Guenes, Gymenna Maria
    Ramos Eloy Dantas, Darlene Cristina
    Cavalcant, Alessandro Leite
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2009, 9 (01): : 49 - 54
  • [9] Effect of smear layer and surface roughness on resin-dentin bond strength of self-etching adhesives
    Saikaew, Pipop
    Senawongse, Pisol
    Chowdhury, A. F. M. Almas
    Sano, Hidehiko
    Harnirattisai, Choltacha
    DENTAL MATERIALS JOURNAL, 2018, 37 (06) : 973 - 980
  • [10] Effects of aging on the bond strength of self-etching adhesives and resin luting cements
    Cetin, Ali Riza
    Unlu, Nimet
    Cebe, Mehmet Ata
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (01) : 61 - 67