Performance of CdTe detector in the 13-1333 keV energy range

被引:9
|
作者
Demir, Demet [1 ]
Onder, Pinar [1 ]
Oznuluer, Tuba [2 ]
机构
[1] Ataturk Univ, Fac Sci, Dept Phys, TR-25240 Erzurum, Turkey
[2] Ataturk Univ, Fac Sci, Dept Chem, TR-25240 Erzurum, Turkey
关键词
CdTe detector; Efficiency; Peak to valley ratio; Energy resolution; RAY; ABSORPTION;
D O I
10.1016/j.radphyschem.2010.06.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The photopeak efficiency, peak to valley ratio and energy resolution of a 3 x 3 x 1 mm(3) CdTe detector were determined experimentally for 13-1333 keV photon energy by using polyester coated radio-isotopes (241)Am, (22)Na, (54)Mn, (57)CO, (60)Co, (109)Cd, (137)Cs and (133)Ba. The data were analyzed by using PX4 from Amptek. The experimental values were fitted to an analytical function of photon energy, and an agreement was observed for the entire range of the studied energies. The results have shown that the CdTe detector has a high performance due to both the improved charge collection efficiency comparable with that of SI GaAs detectors (Vittone et al., 1999), and the low leakage current. Also, CdTe detector is very attractive for field application as it works at room temperature. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1132 / 1136
页数:5
相关论文
共 50 条
  • [1] Efficiency determination for NaI (Tl) detectors in the 23 keV to 1333 keV energy range
    Demir, Dernet
    Un, Adern
    Sabin, Yusuf
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2008, 36 (03) : 291 - 301
  • [2] Energy sensitive particle detector in energy range of <10 keV
    Shiki, S.
    Ukibe, M.
    Ohkubo, M.
    Hayakawa, S.
    Sato, Y.
    Tomita, S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2009, 469 (15-20): : 1674 - 1676
  • [3] PERFORMANCE OF A MICROCHANNEL PLATE ION DETECTOR IN THE ENERGY-RANGE 3-25 KEV
    HELLSING, M
    KARLSSON, L
    ANDREN, HO
    NORDEN, H
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (11): : 920 - 925
  • [4] A New Detector for Backscattered Helium Ions in the 30 keV Energy Range
    Sijbrandij, Sybren
    Notte, John
    Thompson, Bill
    Chuong Huynh
    Sanford, Colin
    Scipioni, Larry
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 220 - 221
  • [5] Time and position sensitive photon detector for coincidence measurements in the keV energy range
    Ismail, Iyas
    Journel, Loic
    Vacheresse, Regis
    Palaudoux, Jerome
    Marin, Thierry
    Penent, Francis
    Simon, Marc
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (11):
  • [6] PERFORMANCE OF A 6-MM THICK CDTE DETECTOR FOR 166 KEV GAMMA-RAYS
    MCKEE, BTA
    GOETZ, T
    HAZLETT, T
    FORKERT, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (03): : 825 - 833
  • [7] Performance of multilayer array analyzer detector in the intermediate energy region (1 KeV to 3 KeV)
    Zhang, Ke
    Rosenbaum, Gerd
    Liu, Qian
    Fischer, Daniel
    X-RAY ABSORPTION FINE STRUCTURE-XAFS13, 2007, 882 : 923 - +
  • [8] Studies on effective atomic numbers and electron densities in amino acids and sugars in the energy range 30-1333 keV
    Gowda, S
    Krishnaveni, S
    Gowda, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 361 - 369
  • [9] POSITION-SENSITIVE DETECTOR FOR HEAVY ATOMIC PARTICLES IN KEV ENERGY-RANGE
    OLSEN, JO
    NUCLEAR INSTRUMENTS & METHODS, 1977, 140 (01): : 29 - 35
  • [10] The efficiency determination for Si(Li) detector in the 3-723 keV energy range
    Yalcin, P.
    Sueluen, A.
    Bastug, A.
    Kurucu, Y.
    Sahin, Y.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (03): : 108 - 115