Monitoring of subsynchronous oscillation in a series-compensated wind power system using an adaptive extended Kalman filter

被引:18
|
作者
Shair, Jan [1 ]
Xie, Xiaorong [1 ]
Yuan, Liang [2 ]
Wang, Yanhui [3 ]
Luo, Yongzhi [3 ]
机构
[1] Tsinghua Univ, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[3] State Grid East Inner Mongolia Elect Power Supply, Hohhot 010000, Peoples R China
基金
中国国家自然科学基金;
关键词
nonlinear filters; oscillations; wind power plants; Kalman filters; adaptive Kalman filters; adaptive filters; fundamental frequency; AEKF; actual wind power system; captured fundamental dynamics; subsynchronous dynamics; subsynchronous oscillation; series-compensated wind power system; adaptive extended Kalman filter; SSO event; Kalman filtering based frequency tracking algorithms; joint tracking; fundamental SSO; Kalman filtering algorithm; process noise covariance factor changes; fundamental component deviates; time-varying subsynchronous component;
D O I
10.1049/iet-rpg.2020.0280
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The characteristics of subsynchronous oscillation (SSO) in series-compensated wind power systems are significantly affected by the system's operating condition. Besides the variation in the magnitude and frequency of the SSO during an SSO event, the fundamental frequency may also deviate from its nominal value. This study aims at capturing the dynamics of both subsynchronous and fundamental frequency components simultaneously. This work first explores the strengths and weaknesses of various Kalman filtering based frequency tracking algorithms for joint tracking of the fundamental and SSO components. Then, it proposes a novel adaptive extended Kalman filtering (AEKF) algorithm, in which the process noise covariance is updated online by maximising the probability density function of the predicted error. The process noise covariance factor changes to positive non-zero value whenever the frequency of the fundamental component deviates. Thus, the proposed AEKF extracts the time-varying subsynchronous component while also tracking the small variations in the fundamental frequency. The tracking performance of the AEKF is validated on computer-generated test signals as well as on the electromagnetic transient simulation model of an actual wind power system facing SSO. The captured fundamental and subsynchronous dynamics can be used for designing monitoring, protection, and control schemes for the SSO.
引用
收藏
页码:4193 / 4203
页数:11
相关论文
共 50 条
  • [1] Adaptive-Reset Extended Kalman Filter Method for Subsynchronous Oscillation Monitoring
    Chen, Xi
    Wu, Xi
    Li, Qingfeng
    Zhou, Jinyu
    Wu, Chenyu
    Li, Qiang
    Ren, Bixing
    Xu, Ke
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (05) : 6163 - 6180
  • [2] Adaptive Damping Control of Subsynchronous Oscillation in DFIG-Based Wind Farms Connected to Series-Compensated Network
    Shair, Jan
    Xie, Xiaorong
    Yang, Jianjun
    Li, Jingyi
    Li, Haozhi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 1036 - 1049
  • [3] A study model for subsynchronous resonance in DFIG based wind farms connected to a series-compensated power system
    Yang B.
    Zhan Y.
    Xie X.
    Yan G.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (08): : 120 - 126
  • [4] Mitigation of subsynchronous resonance in a series-compensated wind farm using FACTS controllers
    Varma, Rajiv K.
    Auddy, Soubhik
    Semsedini, Ysni
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) : 1645 - 1654
  • [5] Robust subsynchronous damping control to stabilise SSR in series-compensated wind power systems
    Zhang, Xu
    Xie, Xiaorong
    Liu, Hui
    Li, Yunhong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (03) : 337 - 344
  • [6] Enhanced Compensation Filter to Mitigate Subsynchronous Oscillations in Series-Compensated DFIG-Based Wind Farms
    Leon, Andres E.
    Amodeo, Santiago J.
    Mauricio, Juan Manuel
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3805 - 3814
  • [7] Improved subsynchronous oscillation detection method in a DFIG-based wind farm interfaced with a series-compensated network
    Abdeen, Mohamed
    Li, Hui
    Jing, Liu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 119
  • [8] Impacting factors and stable area analysis of subsynchronous resonance in DFIG based wind farms connected to series-compensated power system
    Dong, Xiaoliang
    Xie, Xiaorong
    Yang, Yu
    Han, Yingduo
    Dianwang Jishu/Power System Technology, 2015, 39 (01): : 189 - 193
  • [9] SUBSYNCHRONOUS RESONANCE OSCILLATIONS OF SERIES-COMPENSATED TRANSMISSION-SYSTEM AND THEIR SUPPRESSIONS
    MUROTANI, K
    ASANO, M
    ELECTRICAL ENGINEERING IN JAPAN, 1976, 96 (06) : 113 - 121
  • [10] Characteristic Analysis of Subsynchronous Resonance in Practical Wind Farms Connected to Series-Compensated Transmissions
    Xie, Xiaorong
    Zhang, Xu
    Liu, Huakun
    Liu, Hui
    Li, Yunhong
    Zhang, Chuanyu
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (03) : 1117 - 1126