Computing the influences of different Intraocular Pressures on the human eye components using computational fluid-structure interaction model

被引:14
|
作者
Karimi, Alireza [1 ]
Razaghi, Reza [2 ]
Navidbakhsh, Mahdi [3 ]
Sera, Toshihiro [1 ]
Kudo, Susumu [1 ]
机构
[1] Kyushu Univ, Dept Mech Engn, Fukuoka 8190395, Japan
[2] Basir Eye Hlth Res Ctr, Tehran 14186, Iran
[3] Islamic Azad Univ, Sci & Res Branch, Dept Biomech, Tehran 7554515, Iran
关键词
Human eye; Intraocular Pressure; keratoconus; fluid-structure interaction; stresses and deformations; CORNEAL BIOMECHANICAL PROPERTIES; FINITE-ELEMENT SIMULATION; POLYVINYL-ALCOHOL SPONGE; IN-SITU KERATOMILEUSIS; OCULAR RIGIDITY; KERATOCONUS CORNEAS; ELASTICITY; COLLAGEN; INJURY; ORGANIZATION;
D O I
10.3233/THC-161280
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Intraocular Pressure (IOP) is defined as the pressure of aqueous in the eye. It has been reported that the normal range of IOP should be within the 10-20 mmHg with an average of 15.50 mmHg among the ophthalmologists. Keratoconus is an anti-inflammatory eye disorder that debilitated cornea unable to reserve the normal structure contrary to the IOP in the eye. Consequently, the cornea would bulge outward and invoke a conical shape following by distorted vision. In addition, it is known that any alterations in the structure and composition of the lens and cornea would exceed a change of the eye ball as well as the mechanical and optical properties of the eye. OBJECTIVE: Understanding the precise alteration of the eye components' stresses and deformations due to different IOPs could help elucidate etiology and pathogenesis to develop treatments not only for keratoconus but also for other diseases of the eye. METHODS: In this study, at three different IOPs, including 10, 20, and 30 mmHg the stresses and deformations of the human eye components were quantified using a Three-Dimensional (3D) computational Fluid-Structure Interaction (FSI) model of the human eye. RESULTS: The results revealed the highest amount of von Mises stress in the bulged region of the cornea with 245 kPa at the IOP of 30 mmHg. The lens was also showed the von Mises stress of 19.38 kPa at the IOPs of 30 mmHg. In addition, by increasing the IOP from 10 to 30 mmHg, the radius of curvature in the cornea and lens was increased accordingly. In contrast, the sclera indicated its highest stress at the IOP of 10 mmHg due to over pressure phenomenon. The variation of IOP illustrated a little influence in the amount of stress as well as the resultant displacement of the optic nerve. CONCLUSION: These results can be used for understanding the amount of stresses and deformations in the human eye components due to different IOPs as well as for clarifying significant role of IOP on the radius of curvature of the cornea and the lens.
引用
收藏
页码:285 / 297
页数:13
相关论文
共 50 条
  • [1] Computing the stresses and deformations of the human eye components due to a high explosive detonation using fluid-structure interaction model
    Karimi, Alireza
    Razaghi, Reza
    Navidbakhsh, Mahdi
    Sera, Toshihiro
    Kudo, Susumu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (05): : 1042 - 1050
  • [2] Fluid-structure interaction analysis for dynamic intraocular pressure monitoring in the human eye
    Kim, Yooil
    Oho, Jung-Sik
    Jung, Gwang-Yong
    Kim, Gi-Woo
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2019, 2019, 10970
  • [3] Collision of the glass shards with the eye: A computational fluid-structure interaction model
    Karimi, Alireza
    Razaghi, Reza
    Biglari, Hasan
    Sera, Toshihiro
    Kudo, Susumu
    JOURNAL OF CHEMICAL NEUROANATOMY, 2018, 90 : 80 - 86
  • [4] Quantifying the injury of the human eye components due to tennis ball impact using a computational fluid–structure interaction model
    Karimi A.
    Razaghi R.
    Navidbakhsh M.
    Sera T.
    Kudo S.
    Sports Engineering, 2016, 19 (2) : 105 - 115
  • [5] Computational fluid-structure interaction model for parachute inflation
    Benney, RJ
    Stein, KR
    JOURNAL OF AIRCRAFT, 1996, 33 (04): : 730 - 736
  • [6] Dynamic Response of Intraocular Pressure and Biomechanical Effects of the Eye Considering Fluid-Structure Interaction
    Salimi, S.
    Park, S. Simon
    Freiheit, T.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [7] A comparative study to determine the optimal intravitreal injection angle to the eye: A computational fluid-structure interaction model
    Karimi, Alireza
    Razaghi, Reza
    Biglari, Hasan
    Sabbaghi, Hamideh
    Sera, Toshihiro
    Kudo, Susumu
    TECHNOLOGY AND HEALTH CARE, 2018, 26 (03) : 483 - 498
  • [8] FLUID-STRUCTURE INTERACTION MODEL OF A SYNTHETIC JET USING COUPLED COMPUTATIONAL FLUID DYNAMICS AND FINITE ELEMENTS
    Seeley, Charles E.
    Weaver, Stan
    Rush, Brian
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, VOL 1, 2012, : 537 - 544
  • [9] Computational fluid-structure interaction simulation of airflow in the human upper airway
    Pirnar, Jernej
    Dolenc-Groselj, Leja
    Fajdiga, Igor
    Zun, Iztok
    JOURNAL OF BIOMECHANICS, 2015, 48 (13) : 3685 - 3691
  • [10] A computational fluid-structure interaction model for plaque vulnerability assessment in atherosclerotic human coronary arteries
    Karimi, Alireza
    Navidbakhsh, Mahdi
    Razaghi, Reza
    Haghpanahi, Mohammad
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (14)