Scatter Artifact with Ga-68-PSMA-11 PET: Severity Reduced With Furosemide Diuresis and Improved Scatter Correction

被引:6
|
作者
Lawhn-Heath, Courtney [1 ]
Flavell, Robert R. [1 ]
Korenchan, David E. [1 ]
Deller, Timothy [2 ]
Lake, Spencer [1 ]
Carroll, Peter R. [3 ]
Hope, Thomas A. [1 ,4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Healthcare, Waukesha, WI USA
[3] Univ Calif San Francisco, Dept Urol, San Francisco, CA 94143 USA
[4] San Francisco VA Med Ctr, Dept Radiol, San Francisco, CA USA
来源
MOLECULAR IMAGING | 2018年 / 17卷
关键词
cancer detection imaging; clinical translational molecular imaging; PET; cancer imaging; PSMA; GA-68-LABELED PSMA LIGAND; TIME-OF-FLIGHT; PROSTATE-CANCER; LESION DETECTABILITY; FORCED DIURESIS; IMAGE QUALITY; WHOLE-BODY; T PET/CT; HBED-CC; PET/MRI;
D O I
10.1177/1536012118811741
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Purpose: To assess the utility of furosemide diuresis and the role of an improved scatter correction algorithm in reducing scatter artifact severity on Ga-68- Prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET). Materials and Methods: A total of 139 patients underwent Ga-68-PSMA-11 PET imaging for prostate cancer: 47 non-time-of-flight (non-TOF) PET/computed tomography, 51 PET/magnetic resonance imaging (MRI) using the standard TOF scatter correction algorithm, and 41 PET/MRI using an improved TOF scatter correction algorithm. Whole-body PET acquisitions were subdivided into 3 regions: around kidneys; between kidneys and bladder; and around bladder. The images were reviewed, and scatter artifact severity was rated using a Likert-type scale. Results: The worst scatter occurred when using non-TOF scatter correction without furosemide, where 42.1% of patients demonstrated severe scatter artifacts in 1 or more regions. Improved TOF scatter correction resulted in the smallest percentage of studies with severe scatter (6.5%). Scatter ratings by region were lowest using improved TOF scatter correction. Furosemide reduced mean scatter severity when using non-TOF and standard TOF. Conclusions: Both furosemide and scatter correction algorithm play a role in reducing scatter in PSMA PET. Improved TOF scatter correction resulted in the lowest scatter severity.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Scatter artifact with 68Ga PSMA-PET: severity reduced with furosemide diuresis and improved time-of-flight scatter correction
    Heath, Courtney Lawhn
    Flavell, Robert
    Deller, Timothy
    Lake, Spencer
    Carroll, Peter
    Hope, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [2] Improving Scatter Correction for Ga-68 PSMA PET Studies
    Hong, Inki
    Nekolla, Stephan G.
    Michel, Christian
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [3] Clinical Evaluation of 68Ga-PSMA-ΙΙ and 68Ga-RM2 PET Images Reconstructed With an Improved Scatter Correction Algorithm
    Wangerin, Kristen A.
    Baratto, Lucia
    Khalighi, Mohammad Mehdi
    Hope, Thomas A.
    Gulaka, Praveen K.
    Deller, Timothy W.
    Iagaru, Andrei H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 655 - 660
  • [4] The importance of precursor concentration for PET diagnostics with Ga-68-PSMA-11
    Nithack, N.
    Zhao, Y.
    Helm, A.
    Luetzen, U.
    Zuhayra, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S408 - S408
  • [5] Improving 68Ga-PSMA PET/MRI of the Prostate with Unrenormalized Absolute Scatter Correction
    Lindemann, Maike E.
    Guberina, Nika
    Wetter, Axel
    Fendler, Wolfgang P.
    Jakoby, Bjoern
    Quick, Harald H.
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (11) : 1642 - 1648
  • [6] Assessment of whole-body scatter correction for Ga-68 PSMA PETCT
    Bal, H.
    Hong, I.
    Buther, F.
    Aykac, M.
    Schaefers, K.
    Conti, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S361 - S362
  • [7] Improved Scatter Correction to Eliminate Halo Artifacts for 68Ga-Labeled Radiopharmaceuticals in PET Imaging
    Wangerin, Kristen
    Iagaru, Andrei
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (09) : 1334 - 1334
  • [8] Methods for reducing 'halo' scatter artefact in Ga-68 PSMA PET/CT and PET/MRI
    Sanderson, T.
    Thomas, B. A.
    Wan, S.
    Dickson, J. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S338 - S339
  • [9] 68Ga Scatter Correction to Eliminate Halo-Artifacts in PET Imaging
    Wangerin, Kristen
    Iagaru, Andrei
    UROLOGY, 2019, 131 : 262 - 262
  • [10] Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI
    Heusser, Thorsten
    Mann, Philipp
    Rank, Christopher M.
    Schaefer, Martin
    Dimitrakopoulou-Strauss, Antonia
    Schlemmer, Heinz-Peter
    Hadaschik, Boris A.
    Kopka, Klaus
    Bachert, Peter
    Kachelriess, Marc
    Freitag, Martin T.
    PLOS ONE, 2017, 12 (08):