What constitutes effective management of pneumothorax after CT-guided needle biopsy of the lung?

被引:4
|
作者
Haramati, LB
机构
[1] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Radiol, Bronx, NY 10467 USA
[2] Tel Aviv Univ, IL-69978 Tel Aviv, Israel
[3] Tel Aviv Sourasky Med Ctr, Tel Aviv, Israel
关键词
D O I
10.1378/chest.121.4.1013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页码:1013 / 1015
页数:3
相关论文
共 50 条
  • [1] Pneumothorax after CT-Guided Lung Biopsy: What Next?
    Shera, Faiz Altaf
    Shera, Tahleel Altaf
    Shah, Omair Ashraf
    Robbani, Irfan
    Choh, Naseer Ahmad
    Shaheen, Feroze
    Gojawari, Tariq Ahmad
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2023, 33 (03): : 309 - 314
  • [2] Management of pneumothorax after percutaneous CT-guided lung biopsy
    Yamagami, T
    Nakamura, T
    Iida, S
    Kato, T
    Nishimura, T
    CHEST, 2002, 121 (04) : 1159 - 1164
  • [3] Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT
    Chami, H. A.
    Faraj, W.
    Yehia, Z. A.
    Badour, S. A.
    Sawan, P.
    Rebeiz, K.
    Safa, R.
    Saade, C.
    Ghandour, B.
    Shamseddine, A.
    Mukherji, D.
    Haydar, A. A.
    CLINICAL RADIOLOGY, 2015, 70 (12) : 1382 - 1387
  • [4] Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy
    Traill, ZC
    Gleeson, FV
    THORAX, 1997, 52 (06) : 581 - 582
  • [5] Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    Kazerooni, EA
    Lim, FT
    Mikhail, A
    Martinez, FJ
    RADIOLOGY, 1996, 198 (02) : 371 - 375
  • [6] Use of spirometry to predict risk of pneumothorax in CT-guided needle biopsy of the lung
    GarciaRio, F
    Pino, JM
    Casadevall, J
    Gomez, L
    Atienza, JM
    DiazLobato, S
    Villamor, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) : 20 - 23
  • [7] Ultrasound monitoring of pneumothorax after CT-guided transthoracic lung biopsy
    Everloff, N.
    Juel, A. Dandanell
    Laursen, C.
    Graumann, O.
    Pietersen, P. I.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [8] Effect of puncture sites on pneumothorax after lung CT-guided biopsy
    Zeng, Li-Chuan
    Liao, Hua-Qiang
    Wu, Wen-Bin
    Zhang, Yu-Dong
    Ren, Feng-Chun
    Wang, Qu
    Xie, Ming-Guo
    MEDICINE, 2020, 99 (15) : E19656
  • [9] Development and validation of a prediction model of pneumothorax after CT-guided coaxial core needle lung biopsy
    Zhao, Yanfeng
    Bao, Dan
    Wu, Wenli
    Tang, Wei
    Xing, Gusheng
    Zhao, Xinming
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 5404 - 5419
  • [10] Lung radiodensity along the needle passage is a quantitative predictor of pneumothorax after CT-guided percutaneous core needle biopsy
    Zhang, H. F.
    Liao, M. Y.
    Zhu, D. Y.
    Chen, J.
    Wang, Y. F.
    CLINICAL RADIOLOGY, 2018, 73 (03) : 319.e1 - 319.e7