Non-target Screening Analysis of Volatile Organic Compounds in Drinking Water by Headspace-Solid Phase Microextraction Gas Chromatography-Mass Spectrometry

被引:12
|
作者
Yu, Ming-Yue [1 ,2 ]
Yang, Xiao-Qiu [1 ]
Fan, Rong [1 ]
Zheng, Yu-Kang [1 ]
Shi, Jian-Bo [2 ,3 ]
Zheng, Qi [1 ]
机构
[1] Jianghan Univ, Key Lab Optoelect Chem Mat & Devices, Minist Educ, Sch Chem & Environm Engn, Wuhan 430056, Peoples R China
[2] Jianghan Univ, Hubei Key Lab Environm & Hlth Effects Persistent, Wuhan 430056, Peoples R China
[3] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 10085, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-target screening; Headspace-solid phase microextraction; Gas chromatography-mass spectrometry; Volatile organic compounds; Drinking water; CHAIN CHLORINATED PARAFFINS; DISINFECTION BY-PRODUCTS; POLLUTION; MS;
D O I
10.1016/S1872-2040(20)60044-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-target screening analytical method for volatile organic compounds (VOCs) in drinking water by headspace-solid phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) was established. The operating parameters of HS-SPME were optimized by the number of peaks and peak area of the extract. The optimum working conditions of four different extracted fibers (100 mu m PDMS, 65 mu m PDMS/DVB, 85 mu m PA and 75 mu m CAR/PDMS) were investigated, including incubation time, extraction time, extraction temperature, NaCl concentration and desorption time. Comparing the species extracted by the four fibers with the oil. water partition ratio coefficient, it was found that the number of substances extracted by 100 mu m PDMS was the least, and the extracted substances overlaped was repeated with other fibers. Therefore, it could be replaced by the three other extraction fibers. The three kinds of extracted fibers were selected for non. target screening of two kinds of tap water samples in Wuhan (the source water came from the Yangtze river and the Hanjiang river), and the substances with matching degree greater than 70% were selected for analysis. The results showed that 35 substances were identified from the tap water samples from the Han River, and 34 substances were identified from the tap water samples from the Yangtze River. The two had 18 common substances. By comparing the types of substances screened in the two water samples, it was found that the esters were the most abundant substances, followed by the aldehydes and phenols. Organic solvents was not used in the whole process, and the pollution caused by the solvent could avoided. The method was friendly to the environment, and could be used for screening and analysis of VOCs in tap water.
引用
收藏
页码:1228 / 1235
页数:8
相关论文
共 32 条
  • [1] Nontargeted Screening of Halogenated Organic Compounds in Bottlenose Dolphins (Tursiops truncatus) from Rio de Janeiro, Brazil
    Alonso, Mariana B.
    Maruya, Keith A.
    Dodder, Nathan G.
    Lailson-Brito, Jose, Jr.
    Azevedo, Alexandre
    Santos-Neto, Elitieri
    Torres, Joao P. M.
    Malm, Olaf
    Hoh, Eunha
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (03) : 1176 - 1185
  • [2] Evaluating gas chromatography with a halogen-specific detector for the determination of disinfection by-products in drinking water
    Andersson, Anna
    Ashiq, Muhammad Jamshaid
    Shoeb, Mohammad
    Karlsson, Susanne
    Bastviken, David
    Kylin, Henrik
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (08) : 7305 - 7314
  • [3] Solid-phase microextraction for the analysis of short-chain chlorinated paraffins in water samples
    Castells, P
    Santos, FJ
    Galceran, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (01) : 1 - 8
  • [4] Pollution Characteristics and Health Risk Assessment of Volatile Organic Compounds (VOCs) and Semi-volatile Organic Compounds (SVOCs) in Qiantang River's Hangzhou Section During a Water Odor Pollution Event
    Chen F.
    Tang F.-L.
    Xu J.-F.
    Wang Y.-Y.
    Ruan D.-D.
    Zhang W.
    Zhou S.
    [J]. Huanjing Kexue/Environmental Science, 2018, 39 (02): : 648 - 654
  • [5] Deng S, 2016, 2016 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), P1201, DOI 10.1109/ISGT-Asia.2016.7796556
  • [6] FAN L, 2014, J JIANGNAN U NATURAL, V13, P355, DOI 10.3969/j.issn.1671-7147.2014.03.019
  • [7] [冯丽丽 Feng Lili], 2019, [分析测试学报, Journal of Instrumental Analysis], V38, P1294
  • [8] Parameters optimization using experimental design for headspace solid phase micro-extraction analysis of short-chain chlorinated paraffins in waters under the European water framework directive
    Gandolfi, F.
    Malleret, L.
    Sergent, M.
    Doumenq, P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1406 : 59 - 67
  • [9] GB Standardization Administration of China, 2006, 57492006 GB
  • [10] He Y.B., 1994, ENV CHEM, V13, P195