Design and performance of a system for two-dimensional readout of gas electron multiplier detectors for proton range radiography

被引:0
|
作者
Wiacek, Piotr [1 ]
Dabrowski, Wladyslaw [1 ]
Fiutowski, Tomasz [1 ]
Mindur, Bartosz [1 ]
Zielinska, Alicja [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
关键词
front-end electronics; GEM detectors; 2-D imaging; proton range radiography;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The proton range radiography (PRR) technique being developed is expected to provide significant improvements in precision delivery of the therapeutic dose in the hadron therapy. The technique requires measuring residual energies and trajectories of mono-energetic protons passing through an object to be imaged. Such an imaging system can be operated in-situ before and after the treatment allowing real time monitoring of the irradiated tissue position. A detector system suitable for such applications must be capable of measuring proton tracks with submillimeter spatial resolution over area of 30 x 30 cm(2). In order to limit the exposure time and obtain real-time images the detector and data acquisition must provide capability of measuring high proton rates up to 10(6) s(-1). In this paper we present novel concept of two-dimensional (2-D) readout of the gas electron multiplier (GEM) detectors used as the position sensitive detectors. The key component of the system is an application specific integrated circuit (ASIC) named GEMROC. The GEMROC comprises 32 independent channels, each one capable of measuring the amplitude and the time of incoming signals. The positions are then reconstructed by coincidences of signals from the X- and Y-readout strips. The design and performance of the GEMROC ASIC are discussed and the results obtained for a test bench based on a smaller 10 x 10 cm(2) GEM chamber are presented. The test results demonstrate clearly that with respect to the two critical parameters, i.e. the noise and the count rate capability, the developed readout system meets the requirements for clinical applications of the PRR technique.
引用
收藏
页码:513 / 519
页数:7
相关论文
共 50 条
  • [1] A compact system for two-dimensional readout of Gas Electron Multiplier detectors
    Mindur, B.
    Dabrowski, W.
    Fiutowski, T.
    Wiacek, P.
    Zielinska, A.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [2] Design and Performance of the GEMROC ASIC for 2-D Readout of Gas Electron Multiplier Detectors
    Fiutowski, Tomasz
    Dabrowski, Wladyslaw
    Mindur, Bartosz
    Wiacek, Piotr
    Zielinska, Alicja
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1540 - 1544
  • [3] The study of the two-dimensional position sensitive gas electron multiplier based on strips readout
    Dong Jing
    Lue Xin-Yu
    Liu Ben
    Liu Rong-Guang
    Ma Xiao-Yan
    Wang Lan
    Chen Yuan-Bo
    Ouyang Qun
    Xie Yi-Gang
    ACTA PHYSICA SINICA, 2010, 59 (09) : 6029 - 6035
  • [4] Two-dimensional readout of GEM detectors
    Bressan, A
    De Oliveira, R
    Gandi, A
    Labbé, JC
    Ropelewski, L
    Sauli, F
    Mörmann, D
    Müller, T
    Simonis, HJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2): : 254 - 261
  • [5] Study of the two dimensional imaging performance for the gas electron multiplier using the resistive anode readout method
    Ju Xu-Dong
    Dong Ming-Yi
    Zhou Chuan-Xing
    Dong Jing
    Zhao Yu-Bin
    Zhang Hong-Yu
    Qi Hui-Rong
    Qun, Ouyang
    ACTA PHYSICA SINICA, 2017, 66 (07)
  • [6] Ultrafast soft x-ray two-dimensional plasma imaging system based on gas electron multiplier detector with pixel readout
    Pacella, D
    Pizzicaroli, G
    Gabellieri, L
    Leigheb, M
    Bellazzini, R
    Brez, A
    Gariano, G
    Latronico, L
    Lumb, N
    Spandre, G
    Massai, MM
    Reale, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (02): : 1372 - 1378
  • [7] A mixed-signal ASIC for the readout of Gas Electron Multiplier detectors Design review and characterization results
    Cossio, Fabio
    2017 13TH CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), 2017, : 33 - 36
  • [8] Two-dimensional PIC-MCC Simulations of the Electron Multiplication in a Gas Electron Multiplier
    Zhang, P. P.
    Tu, Y.
    Yang, Y. Y.
    Tolner, H.
    PROCEEDINGS OF CHINA DISPLAY/ASIA DISPLAY 2011, 2011, : 782 - 784
  • [9] A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout
    Hanu, A. R.
    Prestwich, W. V.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 33 - 39
  • [10] Short-range correlations in a two-dimensional electron gas
    Polini, M
    Sica, G
    Davoudi, B
    Tosi, MP
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2001, 13 (15) : 3591 - 3597