Diagnostic performance of whole-body bone scintigraphy in combination with SPECT/CT for detection of bone metastases

被引:11
|
作者
Zhang, Yiqiu [1 ,2 ,3 ]
Li, Beilei [1 ,2 ,3 ]
Wu, Bing [1 ,2 ,3 ]
Yu, Haojun [1 ,2 ,3 ]
Song, Junyi [1 ,2 ,3 ]
Xiu, Yan [1 ,2 ,3 ]
Shi, Hongcheng [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Nucl Med, Shanghai 200032, Peoples R China
[2] Fudan Univ, Inst Nucl Med, Shanghai 200032, Peoples R China
[3] Shanghai Inst Med Imaging, Shanghai 200032, Peoples R China
关键词
SPECT; CT; Malignant tumor; Diagnostic; Bone metastases; SPECT/SPIRAL CT; LESIONS; TOMOGRAPHY; IMPROVE; CANCER; BENIGN; SPINE;
D O I
10.1007/s12149-020-01488-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective This retrospective study investigated the performance of whole-body bone scintigraphy combined with SPECT/CT and established a grading diagnostic criterion for bone metastases. Methods We summarized signs of whole-body bone imaging combined with SPECT in nuclear medicine and CT signs of corresponding parts. Then we established a diagnostic criterion for bone metastases by using whole-body bone scintigraphy combined with local SPECT/CT. The criterion is classified into five grades. 120 patients with a total of 141 lesions underwent whole-body bone scintigraphy and SPECT/CT. Two reviewers read the images according to the diagnostic criterion. With pathological diagnosis as the "gold standard", the diagnostic efficacy for bone metastases and the diagnostic agreement between the two reviewers were analyzed to validate the feasibility of the criterion. Diagnostic effectiveness was expressed in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Results The diagnostic accuracy of the two reviewers was 90.1% and 92.9% respectively, sensitivity was both 100%, specificity was 41.7% and 58.3%, positive predictive value was 89.3% and 92.1%, and negative predictive value was both 100%. The kappa value of the diagnostic tests performed by the two reviewers on whole-body bone scintigraphy combined with SPECT/CT was 0.919 (P < 0.001). Conclusion The grading diagnostic criterion for bone metastases by whole-body bone scintigraphy combined with SPECT/CT has high diagnostic accuracy and good consistency between reviewers, but the specificity was still low even with SPECT/CT.
引用
收藏
页码:549 / 558
页数:10
相关论文
共 50 条
  • [1] Diagnostic performance of whole-body bone scintigraphy in combination with SPECT/CT for detection of bone metastases
    Yiqiu Zhang
    Beilei Li
    Bing Wu
    Haojun Yu
    Junyi Song
    Yan Xiu
    Hongcheng Shi
    Annals of Nuclear Medicine, 2020, 34 : 549 - 558
  • [2] Comparative study of whole-body MRI and bone scintigraphy for the detection of bone metastases
    Balliu, E.
    Boada, M.
    Pelaez, I.
    Vilanova, J. C.
    Barcelo-Vidal, C.
    Rubio, A.
    Galofre, P.
    Castro, A.
    Pedraza, S.
    CLINICAL RADIOLOGY, 2010, 65 (12) : 989 - 996
  • [3] Comparison of whole-body MRI and bone scintigraphy in the detection of bone metastases in renal cancer
    Sohaib, S. A.
    Cook, G.
    Allen, S. D.
    Hughes, M.
    Eisen, T.
    Gore, M.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (980): : 632 - 639
  • [4] Whole-body SPECT/CT for bone scintigraphy: diagnostic value and effect on patient management in oncological patients
    H. Palmedo
    C. Marx
    A. Ebert
    B. Kreft
    Y. Ko
    A. Türler
    R. Vorreuther
    U. Göhring
    H. H. Schild
    T. Gerhardt
    U. Pöge
    S. Ezziddin
    H.-J. Biersack
    H. Ahmadzadehfar
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 59 - 67
  • [5] Whole-body SPECT/CT: Could Replace Bone Scintigraphy in Cancer Patients?
    Manchon Adsuar, F.
    Diaz Exposito, R.
    Lopez Prior, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S531 - S532
  • [6] Whole-body SPECT/CT for bone scintigraphy: diagnostic value and effect on patient management in oncological patients
    Palmedo, H.
    Marx, C.
    Ebert, A.
    Kreft, B.
    Ko, Y.
    Tuerler, A.
    Vorreuther, R.
    Goehring, U.
    Schild, H. H.
    Gerhardt, T.
    Poege, U.
    Ezziddin, S.
    Biersack, H. -J.
    Ahmadzadehfar, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (01) : 59 - 67
  • [7] Diagnostic accuracy and agreement between whole-body diffusion MRI and bone scintigraphy in detecting bone metastases
    Stecco, A.
    Lombardi, M.
    Leva, L.
    Brambilla, M.
    Negru, E.
    Passeri, S. Delli
    Carriero, A.
    RADIOLOGIA MEDICA, 2013, 118 (03): : 465 - 475
  • [8] Diagnostic accuracy of bone metastases detection in cancer patients: Comparison between bone scintigraphy and whole-body FDG-PET
    Ryota Fujimoto
    Tatsuya Higashi
    Yuji Nakamoto
    Tadashi Hara
    Andrej Lyshchik
    Koichi Ishizu
    Hidekazu Kawashima
    Shigeto Kawase
    Toru Fujita
    Tsuneo Saga
    Kaori Togashi
    Annals of Nuclear Medicine, 2006, 20 : 399 - 408
  • [9] Diagnostic accuracy of bone metastases detection in cancer patients: Comparison between bone scintigraphy and whole-body FDG-PET
    Fujimoto, Ryota
    Higashi, Tatsuya
    Nakamoto, Yuji
    Hara, Tadashi
    Lyshchik, Andrej
    Ishizu, Koichi
    Kawashima, Hidekazu
    Kawase, Shigeto
    Fujita, Toru
    Saga, Tsuneo
    Togashi, Kaori
    ANNALS OF NUCLEAR MEDICINE, 2006, 20 (06) : 399 - 408
  • [10] A prospective study determining and comparing the diagnostic accuracy of fluoride-PET/CT, choline-PET/CT, whole-body bone SPECT/CT and whole-body MRI for the detection of bone metastases in patients with prostate cancer
    Dyrberg E.
    Hendel H.W.
    Løgager V.B.
    Madsen C.
    Pedersen E.M.
    Zerahn B.
    Thomsen H.S.
    European Journal of Hybrid Imaging, 2 (1):