Comparison of dynamic hip screw and antirotation screw with cannulated screw in the treatment of transcervical collum femoris fractures

被引:13
|
作者
Sahin, Adem [1 ]
Agar, Anil [1 ]
Gulabi, Deniz [1 ]
Erturk, Cemil [1 ]
机构
[1] Univ Hlth Sci, Kanuni Sultan Suleyman Training & Res Hosp, Dept Orthoped & Traumatol, Istanbul, Turkey
来源
JOINT DISEASES AND RELATED SURGERY | 2020年 / 31卷 / 02期
关键词
Femoral neck fracture; femur head necrosis; fluoroscopy; fractures; internal fixators; non-union; operation time; NECK FRACTURES; INTERNAL-FIXATION; INTRACAPSULAR FRACTURES; MANAGEMENT;
D O I
10.5606/ehc.2020.73416
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aims to compare the results of internal fixation with dynamic hip screw (DHS)/antirotation screw and conventional cannulated screw (CS) for femoral neck fracture. Patients and methods: This retrospective study included a total of 78 patients (57 males, 21 females) with collum femoris fractures treated with internal fixation between January 2015 and January 2019. Group 1 comprised 41 patients with a mean age of 45.7 years (range, 19 to 62 years) treated with DHSs/antirotation screws, while group 2 comprised 37 patients with a mean age of 41.9 years (range, 17 to 75 years) treated with CSs. The patients were evaluated for union, avascular necrosis (AVN), femoral neck shortness, operation time, duration of fluoroscopy exposure, and functional outcomes. Results: Age, gender, and Garden classification stages were similar in both groups. No significant difference was found between the groups in respect of AVN and non-union rates. The non-union rate was 12.2% in group 1 and 21.6% in group 2 (p 0.05). The duration of fluoroscopy exposure was statistically significantly higher in group 2 (p=0.001) and the operation time was statistically significantly longer in group 1 (p=0.001). In group 2, femoral neck shortness stature was significantly higher (p=0.007). At the final follow-up examination, the Harris hip score was statistically significantly higher in group 1 (p=0.04). Conclusion: Dynamic hip screw/antirotation screw was a more relevant treatment method for transcervical femoral neck fractures compared to CS with more favorable functional outcomes and less fluoroscopy exposure.
引用
收藏
页码:320 / 327
页数:8
相关论文
共 50 条
  • [1] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [2] A Comparison of Proximal Femoral Nail Antirotation and Dynamic Hip Screw Devices in Trochanteric Fractures
    Zou, J.
    Xu, Y.
    Yang, H.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (04) : 1057 - 1064
  • [3] Biomechanical Comparison of Dynamic Hip Screw, Proximal Femoral Nail, Cannulated Screw, and Monoaxial External Fixation in the Treatment of Basicervical Femoral Neck Fractures
    Imren, Y.
    Gurkan, V.
    Bilsel, K.
    Desteli, E. E.
    Tuna, M.
    Gurcan, C.
    Tuncay, I.
    Sen, C.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2015, 82 (02) : 140 - 144
  • [4] Results of subtrochanteric fractures treated with dynamic hip screw and dynamic condylar screw
    Khallaf, FGM
    Al-Rowaih, A
    Abdul-Hamid, HF
    MEDICAL PRINCIPLES AND PRACTICE, 1998, 7 (04) : 283 - 291
  • [5] OPERATIVE TREATMENT OF PERTROCHANTERIC FRACTURES WITH THE DYNAMIC HIP SCREW
    ORTNER, F
    WAGNER, M
    TROJAN, E
    UNFALLCHIRURG, 1989, 92 (06): : 274 - 281
  • [6] Comparison of Transverse Cancellous Lag Screw and Ordinary Cannulated Screw Fixations in Treatment of Vertical Femoral Neck Fractures
    Dong, Qiang
    Han, Zhe
    Zhang, Yin-Guang
    Sun, Xiang
    Ma, Xin-Long
    ORTHOPAEDIC SURGERY, 2019, 11 (04) : 595 - 603
  • [7] A Comparative Study of Dynamic Hip Screw Versus Multiple Cannulated Compression Screw Fixation in Undisplaced Intracapsular Neck of Femur Fractures
    Cullen, Samuel E.
    Sephton, Benjamin
    Malik, Isfand
    Aldarragi, Ameer
    Crossdale, Martin
    O'Connor, Michael
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [8] Proximal femoral nail antirotation against dynamic hip screw for unstable trochanteric fractures; a prospective randomized comparison
    Zehir, Sinan
    Zehir, R.
    Zehir, Sultan
    Azboy, I.
    Haykir, N.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2015, 41 (04) : 393 - 400
  • [9] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Yih-Shiunn Lee
    Hui-Ling Huang
    Ting-Ying Lo
    Chien-Rae Huang
    International Orthopaedics, 2007, 31 : 683 - 688
  • [10] Comparison of the Intramedullary Nail and Dynamic Hip Screw in the Treatment of Subtrochanteric Femoral Fractures
    Arshad, Z.
    Thahir, A.
    Rawal, J.
    Hull, P.
    Carrothers, A.
    Krkovic, M.
    Chou, D.
    BRITISH JOURNAL OF SURGERY, 2021, 108