A single tube 10-color flow cytometry assay optimizes detection of minimal residual disease in chronic lymphocytic leukemia

被引:22
|
作者
Sartor, M. M. [1 ]
Gottlieb, D. J. [2 ]
机构
[1] Westmead Hosp, Flow Cytometry Unit, ICPMR, Westmead, NSW 2145, Australia
[2] Univ Sydney, Fac Med, Sydney, NSW 2006, Australia
关键词
chronic lymphocytic leukemia; minimal residual disease; multiparameter flow cytometry; STEM-CELL TRANSPLANTATION; CLL PATIENTS; RITUXIMAB; PCR; QUANTIFICATION; ALEMTUZUMAB; MODULATION; TRIAL; CD20;
D O I
10.1002/cyto.b.21067
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Levels of residual disease (RD) are an independent predictor of progression-free survival (PFS) and overall survival (OS) in patients treated for chronic lymphocytic leukemia (CLL). We modified the international standardized approach (ISA) to RD detection using flow cytometry by developing a single tube 10 color antibody assay. Method: A single tube incorporated the following monoclonal antibodies: CD81FITC, CD22PE, CD3ECD, CD5PercP5.5, CD20PECY7, CD79bAPC, CD38A700, CD43APC Alexa750, CD19eFluor 450, and CD45KO. A modified ISA gating strategy was developed that removed contaminating events. Sensitivity assays were performed using dilution with normal peripheral blood and bone marrow. Clinical samples were compared using the ISA and the single tube assay. Results: Dilution studies showed that sensitivity of 0.001% was achievable when a minimum of 1.8 x 106 total events were acquired. One hundred twenty-nine samples were analyzed and showed RD levels from 0.003 to 22%. In 80 samples analyzed with both assays, there was an excellent correlation between the two methods (slope = 1.0, intercept = 0.07 and R2 = 0.992) and results from BlandAltman analysis showed a bias of 0.04 +/- 0.38 with 95% confidence interval of 0.71 to 0.79. Removal of contaminating events in the single tube assay led to a significant reduction in RD values (P = 0.0014). Conclusion: The single tube 10-color assay for the detection of RD in CLL provides equivalent results to the ISA but requires fewer cells, uses fewer reagents, and allows for simpler analysis. By directly removing contaminating events, it improves the accuracy of CLL RD detection and may reclassify the status of some patients following chemotherapy. (c) 2013 International Clinical Cytometry Society
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [1] A 10-color flow cytometry panel for diagnosis and minimal residual disease in chronic lymphocytic leukemia
    Bazinet, Alexandre
    Rys, Ryan N.
    Barry, Amadou
    Greenwood, Celia M. T.
    Young, Yoon Kow
    Mendoza, Alma
    LaPorta, Ida
    Wever, Claudia M.
    Mercier, Francois E.
    Johnson, Nathalie A.
    LEUKEMIA & LYMPHOMA, 2021, 62 (10) : 2352 - 2359
  • [2] A 10-Color Flow Cytometry Panel for Both Diagnosis and Minimal Residual Disease Measurement in Chronic Lymphocytic Leukemia
    Bazinet, Alexandre
    Rys, Ryan N.
    Wever, Claudia M.
    Barry, Amadou
    Greenwood, Celia
    Young, Christian
    Mendoza, Alma
    LaPorta, Ida
    Gimmig, Sylvain
    Mercier, Francois
    Johnson, Nathalie
    BLOOD, 2019, 134
  • [3] MONITORING OF MINIMAL RESIDUAL DISEASE IN MULTIPLE MYELOMA BY A SINGLE-TUBE 10-COLOR FLOW CYTOMETRY
    Shen, Wenhong
    Dai, Lan
    He, Yang
    Zhu, Mingqing
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 107 - 107
  • [4] FLOW CYTOMETRY OR IMMUNOHISTOCHEMISTRY FOR MINIMAL RESIDUAL DISEASE DETECTION IN CHRONIC LYMPHOCYTIC LEUKEMIA?
    Hanson, Curtis
    Amador-Ortiz, Catalina
    Timm, Michael
    Morice, William
    Jevremovic, Dragan
    Shanafelt, Tait
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 51 - 52
  • [5] Minimal residual disease detection in multiple myeloma: comparison between BML single-tube 10-color multiparameter flow cytometry and EuroFlow multiparameter flow cytometry
    Kota Sato
    Kiyoshi Okazuka
    Tadao Ishida
    Jun Sakamoto
    Shigeto Kaneko
    Junichiro Nashimoto
    Yui Uto
    Mizuki Ogura
    Yumiko Yoshiki
    Yu Abe
    Aki Maeda
    Hiroyuki Hamazaki
    Nobuhiro Tsukada
    Yuji Hiragohri
    Kenshi Suzuki
    Annals of Hematology, 2021, 100 : 2989 - 2995
  • [6] Minimal residual disease detection in multiple myeloma: comparison between BML single-tube 10-color multiparameter flow cytometry and EuroFlow multiparameter flow cytometry
    Sato, Kota
    Okazuka, Kiyoshi
    Ishida, Tadao
    Sakamoto, Jun
    Kaneko, Shigeto
    Nashimoto, Junichiro
    Uto, Yui
    Ogura, Mizuki
    Yoshiki, Yumiko
    Abe, Yu
    Maeda, Aki
    Hamazaki, Hiroyuki
    Tsukada, Nobuhiro
    Hiragohri, Yuji
    Suzuki, Kenshi
    ANNALS OF HEMATOLOGY, 2021, 100 (12) : 2989 - 2995
  • [7] Optimization and Validation of an 8-Color Single-Tube Assay for the Sensitive Detection of Minimal Residual Disease in B-Cell Chronic Lymphocytic Leukemia Detected via Flow Cytometry
    Dowling, Anita K.
    Liptrot, Stuart D.
    O'Brien, David
    Vandenberghe, Elisabeth
    LABORATORY MEDICINE, 2016, 47 (02) : 103 - 111
  • [8] Clinical implication of minimal residual disease monitoring by 10-color flow cytometry in multiple myeloma
    姚卫芹
    China Medical Abstracts(Internal Medicine), 2019, 36 (04) : 231 - 232
  • [9] Performance of a novel 8-color flow cytometry panel in the detection of minimal residual disease assessment of chronic lymphocytic leukemia
    Wu, Yujie
    Chen, Xiao
    Zhao, Sishu
    Shi, Yu
    Zhang, Ninghan
    Guo, Zhen
    Qiao, Chun
    Jin, Huimin
    Zhu, Liying
    Zhu, Huayuan
    Li, Jianyong
    LEUKEMIA & LYMPHOMA, 2023, 64 : S104 - S105
  • [10] Improved Concordance of Minimal Residual Disease Measurements By Quantitative PCR and 10-Color Flow Cytometry in Pediatric Acute Lymphoblastic Leukemia
    Sartor, Mary
    Barbaric, Draga
    Law, Tamara
    Dissanayake, Anuruddhika
    Venn, Nicola C.
    Karsa, Mawar
    Wong, Sue W. J.
    Norris, Murray D.
    Revesz, Tamas
    Ritchie, Petra
    Shaw, Peter J.
    Bradstock, Kenneth F.
    Pozza, Luciano Dalla
    Trahair, Toby N.
    Sutton, Rosemary
    BLOOD, 2015, 126 (23)