Low Voltage PFC Measurements and Potential Alternative to Reduce Them at Alcoa Smelters

被引:3
|
作者
Batista, Eliezer [1 ]
Espinoza-Nava, Luis [1 ]
Tulga, Christopher [2 ]
Marcotte, Richard [2 ]
Duchemin, Yan [3 ]
Manolescu, Petre [4 ]
机构
[1] Alcoa Tech Ctr, 859 White Cloud Rd, New Kensington, PA 15068 USA
[2] Alcoa Massena Operat, Pk Ave East, Massena, NY 13662 USA
[3] ALCOA, 5555 Pierre Thibault, Becancour, PQ G9H 2T7, Canada
[4] Alcoa Fjardaal, Hraun 1, IS-730 Reydarfjordur, Iceland
来源
LIGHT METALS 2018 | 2018年
关键词
PFC; Perfluorocarbon; Tetrafluoromethane; Hexafluoroethane; Emission monitoring; EMISSION;
D O I
10.1007/978-3-319-72284-9_191
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Perfluorocarbon (PFC) gases evolve from aluminum electrolysis pots almost continuously. They are not only emitted during anode effects (above 8 V) but also during pot instability periods where pot voltage is below 8 V. The so called "low voltage anode effects" (LVAE) can be emitted during anode changes, pot feeding underfeed cycles or pot tapping periods [1-7]. Procedures are shown how to measure and reduce LVAE. Fourier Transform Infrared (FTIR) method is reviewed to measure the very low emissions as well as together with gas bags used to measure total PFC emissions. Thus, equipment selection, measurements parameters and Quality Assurance/Quality Control (QA/QC) controls should be reinforced to comply with possible regulation change to measure total emissions. Results from feeding optimizations will be shown from three smelters with reduction on LV-PFC emissions.
引用
收藏
页码:1463 / 1467
页数:5
相关论文
共 6 条
  • [1] PFC emission measurements from Alcoa aluminum smelters
    Marks, J
    LIGHT METALS 1998, 1998, : 287 - 291
  • [2] Validation of PFC Slope at Alcoa Canadian Smelters with Anode Effect Assessment and Future Implications to Add Low Voltage Emissions into Total PFC Emissions
    Dubois, Christine
    Batista, Eliezer
    Espinoza-Nava, Luis
    Dubreuil, Alexandre
    LIGHT METALS 2019, 2019, : 849 - 855
  • [3] Low-voltage extraction characteristics of ion beams and space potential measurements on ECRIS
    Owada, I
    Kubo, W.
    Harisaki, S.
    Tsuda, K.
    Sato, K.
    Anan, M.
    Maenaka, T.
    Kato, Y.
    19TH INTERNATIONAL CONFERENCE ON ION SOURCES - ICIS2021, 2022, 2244
  • [4] ANESTHETICS REDUCE THE MAGNITUDE OF THE MEMBRANE DIPOLE POTENTIAL - MEASUREMENTS IN LIPID VESICLES USING VOLTAGE-SENSITIVE SPIN PROBES
    QIN, ZH
    SZABO, G
    CAFISO, DS
    BIOCHEMISTRY, 1995, 34 (16) : 5536 - 5543
  • [5] Dielectric loss and extended voltage response measurements for low-voltage power cables used in nuclear power plant: potential methods for aging detection due to thermal stress
    Mustafa, Ehtasham
    Afia, Ramy S. A.
    Tamus, Zoltan Adam
    ELECTRICAL ENGINEERING, 2021, 103 (02) : 899 - 908
  • [6] Dielectric loss and extended voltage response measurements for low-voltage power cables used in nuclear power plant: potential methods for aging detection due to thermal stress
    Ehtasham Mustafa
    Ramy S. A. Afia
    Zoltán Ádám Tamus
    Electrical Engineering, 2021, 103 : 899 - 908