Quantification of urinary 18-hydroxycortisol using LC-MS/MS

被引:6
|
作者
Jin, Shigeki [1 ]
Wada, Norio [2 ]
Takahashi, Yuji [1 ,3 ]
Hui, Shu-Ping [1 ]
Sakurai, Toshihiro [1 ]
Fuda, Hirotoshi [1 ]
Takeda, Seiji [1 ]
Fujikawa, Masato [3 ]
Yanagisawa, Katsuyuki [2 ]
Ikegawa, Shigeo [4 ]
Kurosawa, Takao [5 ]
Chiba, Hitoshi [1 ]
机构
[1] Hokkaido Univ, Fac Hlth Sci, Sapporo, Hokkaido 0600812, Japan
[2] Sapporo City Gen Hosp, Dept Endocrinol & Diabet, Sapporo, Hokkaido, Japan
[3] Sapporo City Gen Hosp, Dept Clin Lab, Sapporo, Hokkaido, Japan
[4] Kinki Univ, Fac Pharmaceut Sci, Higashiosaka, Osaka 577, Japan
[5] Hlth Sci Univ Hokkaido, Fac Pharmaceut Sci, Hokkaido, Tobetsu, Japan
基金
日本学术振兴会;
关键词
Steroid; mass spectrometry; aldosteronism; hypertension; PERFORMANCE LIQUID-CHROMATOGRAPHY; PRIMARY ALDOSTERONISM; SUBTYPE DIFFERENTIATION; ENZYME-IMMUNOASSAY; DIAGNOSIS; HYPERALDOSTERONISM; CORTICOSTEROIDS; 18-OXOCORTISOL; PREVALENCE;
D O I
10.1177/0004563213476272
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Urinary 18-hydroxycortisol has been investigated as a marker of aldosterone-producing adenoma (APA). The aim of this study was to develop and validate a method for the measurement of 18-hydroxycortisol using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods: Urine was collected over a 24-hour period in patients with APA (n=11), idiopathic hyperaldosteronism (IHA, n=9), and essential hypertension (EH, n=6). 18-Hydroxycortisol was extracted in solid-phase, and measured by LC-MS/MS based on selected reaction monitoring. Results: The method allowed quantification of 18-hydroxycortisol with a lower quantification limit of 0.26nmol/L, intra- and inter-assay coefficients of variation of <3.4% and a range of analytical recovery of 98.0-103.7%. Urinary 18-hydroxycortisol excretion for APA, IHA and EH were determined as 725 (SD 451), 102 (SD 68) and 88 (SD 76) nmol/day, respectively. Conclusions: The proposed method met the basic analytical requirements and was considered to be useful in the screening and differential diagnosis of APA.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 50 条
  • [1] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) based assay for the simultaneous quantification of 18-hydroxycorticosterone, 18-hydroxycortisol and 18-oxocortisol in human plasma
    Chen, Fangjun
    Cheng, Ziyun
    Wang, Zhenxin
    Peng, Yingfei
    Wang, Beili
    Guo, Wei
    Pan, Baishen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1188
  • [2] Quantification of Urinary Albumin by Using Protein Cleavage and LC-MS/MS
    Seegmiller, Jesse C.
    Barnidge, David R.
    Burns, Bradley E.
    Larson, Timothy S.
    Lieske, John C.
    Kumar, Rajiv
    CLINICAL CHEMISTRY, 2009, 55 (06) : 1100 - 1107
  • [3] Optimizing adrenal vein sampling in primary aldosteronism subtyping through LC-MS/MS and secretion ratios of aldosterone, 18-oxocortisol, and 18-hydroxycortisol
    Chang, Yu-Ling
    Chen, Guan-Yuan
    Lee, Bo-Ching
    Chen, Po-Ting
    Liu, Kao-Lang
    Chang, Chin-Chen
    Weng, Te-, I
    Wu, Vin-Cent
    Lin, Yen-Hung
    TAIPAI Study Grp
    HYPERTENSION RESEARCH, 2023, 46 (08) : 1983 - 1994
  • [4] Drugs of abuse quantification using LC-MS/MS
    Gauthier, Jeannette
    Petryayeva, Eleonora
    Nichols, Matthew
    Macri, Joseph
    Potter, Murray
    CLINICAL BIOCHEMISTRY, 2020, 86 : 80 - 80
  • [5] Stoichiometric Quantification of Akt Phosphorylation using LC-MS/MS
    Atrih, Abdelmadjid
    Turnock, Dan
    Sellar, Grant
    Thompson, Alastair
    Ferguson, Michael
    Huang, Jeffrey
    FASEB JOURNAL, 2010, 24
  • [6] Stoichiometric Quantification of Akt Phosphorylation Using LC-MS/MS
    Atrih, Abdelmadjid
    Turnock, Dan
    Sellar, Grant
    Thompson, Alastair
    Feuerstein, Giora
    Ferguson, Michael A. J.
    Huang, Jeffrey T-J.
    JOURNAL OF PROTEOME RESEARCH, 2010, 9 (02) : 743 - 751
  • [7] Monitoring of urinary ethyl glucuronide using LC-MS/MS
    Cengiz, S.
    Anilanmert, B.
    Cavus, F.
    Aydin, M.
    Ozdemir, A. A.
    FEBS JOURNAL, 2013, 280 : 532 - 533
  • [8] Optimizing adrenal vein sampling in primary aldosteronism subtyping through LC–MS/MS and secretion ratios of aldosterone, 18-oxocortisol, and 18-hydroxycortisol
    Yu-Ling Chang
    Guan-Yuan Chen
    Bo-Ching Lee
    Po-Ting Chen
    Kao-Lang Liu
    Chin-Chen Chang
    Te-I Weng
    Vin-Cent Wu
    Yen-Hung Lin
    Hypertension Research, 2023, 46 : 1983 - 1994
  • [9] Quantification of nivolumab in human plasma by LC-MS/HRMS and LC-MS/MS, comparison with ELISA
    Millet, Aurelien
    Khoudour, Nihel
    Bros, Pauline
    Lebert, Dorothee
    Picard, Guillaume
    Machon, Christelle
    Goldwasser, Francois
    Blanchet, Benoit
    Guitton, Jerome
    TALANTA, 2021, 224
  • [10] Automatic quantification analysis of amrubicin and amrubicinol using LC-MS/MS
    Maeda, Makoto
    Amenomiya, Daisuke
    Makihara, Reiko Ando
    Sakiyama, Naomi
    Makino, Yoshinori
    Imoto, Eishi
    Kawakami, Daisuke
    Masuda, Ken
    Shinno, Yuki
    Okuma, Yusuke
    Yoshida, Tatsuya
    Goto, Yasushi
    Horinouchi, Hidehito
    Ishikawa, Mitsunobu
    Saito, Yoshimasa
    Akagi, Toru
    Hashimoto, Hironobu
    Yamamoto, Noboru
    Ohe, Yuichiro
    Furukawa, Tetsuya
    ANNALS OF ONCOLOGY, 2022, 33 : S544 - S544