Analytical approach and occurrence for the determination of mass concentration of PCDD/PCDF and dl-PCB in flue gas emissions using long-term sampling devices

被引:17
|
作者
Rivera-Austrui, J. [1 ]
Martinez, K. [1 ]
Adrados, M. A. [1 ]
Abalos, M. [1 ]
Abad, E. [1 ]
机构
[1] IDAEA CSIC, Lab Dioxins, Dept Environm Chem, Barcelona 08034, Spain
关键词
PCDD/PCDF; dl-PCB; EN-1948; Emissions; Long-term sampling; Method validation; COPLANAR PCBS; START-UP;
D O I
10.1016/j.scitotenv.2012.06.099
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, a reliable methodology for the simultaneous analysis of PCDD/PCDF and dioxin-like PCB (dl-PCB) in flue gas emissions collected using continuous sampling devices is proposed. The analytical scheme followed the minimum requirements described in the EU standard EN-1948:1,2,3,4 according to samples containing large amounts of dioxins and dl-PCBs or samples collected over a long period of time of about 4 weeks. Parameters, such as reproducibility, precision, limits of detection (LOD), limits of quantification (LOQ), extract aliquot size, analytical blanks, extraction efficiency, as well as the amount of internal standards required for an accurate determination, were assessed. The findings demonstrate the suitability of the proposed analytical scheme for the analysis of PCDD/PCDF and PCB in samples collected using long-term sampling devices. The analysis of five different 5% v/v sample aliquots reported %RSD values lower than 10% for all of the 29 congeners at both low and high levels. Similarly. %RSD values were 3.2 and 2.0 for the low level samples and 0.9 and 1.1%RSD for the high level extracts for PCDD/PCDF and dl-PCB, respectively expressed in total TEQ units. Re-extraction provided values less than 3%, expressed in TEQ Based on blank analyses, LOD values of 100 pg I-TEQ for PCDD/PCDF and 10 pg WHO-TEQ for dl-PCB were achieved when 5% v/v aliquots were analyzed. Finally, the proposed analytical approach was tested with samples from a wide range of combustion processes such as hazardous and municipal waste incinerators, as well as cement kilns (with and without waste co-incineration). (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 3 条
  • [1] Long-term automated sampling of PCDD/PCDF flue gas: current status and critical issues
    M. Vicaretti
    S. Mosca
    E. Guerriero
    M. Rotatori
    Environmental Science and Pollution Research, 2012, 19 : 1896 - 1907
  • [2] Long-term automated sampling of PCDD/PCDF flue gas: current status and critical issues
    Vicaretti, M.
    Mosca, S.
    Guerriero, E.
    Rotatori, M.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2012, 19 (06) : 1896 - 1907
  • [3] PCDD, PCDF, AND DL-PCB analysis in food: performance evaluation of the high-resolution gas chromatography/low-resolution tandem mass spectrometry technique using consensus-based samples
    Ingelido, Anna Maria
    Brambilla, Gianfranco
    Abballe, Annalisa
    di Domenico, Alessandro
    Fulgenzi, Anna Rita
    Iacovella, Nicola
    Iamiceli, Anna Laura
    Valentini, Silvia
    De Felip, Elena
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (03) : 236 - 242