A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line

被引:187
作者
Akagi, H [1 ]
Fujita, H [1 ]
Wada, K [1 ]
机构
[1] Okayama Univ, Dept Elect Engn, Okayama 7008530, Japan
关键词
harmonic termination; power distribution systems; pulsewidth modulation inverters; shunt active filters; voltage detection;
D O I
10.1109/28.767015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper is focused on a shunt active filter based on detection of harmonic voltages at the point of installation. The objective of the active filter is to attenuate harmonic propagation resulting from series/parallel resonance between capacitors for power factor correction and line inductors in a power distribution line. The active filter acts as a low resistor to the external circuit for harmonic frequencies, and it is installed on the end bus of the power distribution line, just like a 50-Ohm terminator installed on the end terminal of a signal transmission line. Therefore, the function of the active filter is referred to as "harmonic termination" in this paper. Experimental results obtained from a laboratory system rated at 200 V and 20 kW verify that the active filter for the purpose of harmonic termination has the capability of harmonic damping throughout the power distribution line.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 14 条
[1]   CONTROL STRATEGY OF ACTIVE POWER FILTERS USING MULTIPLE VOLTAGE-SOURCE PWM CONVERTERS [J].
AKAGI, H ;
NABAE, A ;
ATOH, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (03) :460-465
[2]   Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems [J].
Akagi, H .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :354-363
[3]  
AKAGI H, 1996, IEEE T IND APPL, V32, P1313
[4]  
[Anonymous], P 1983 INT POW EL C
[5]  
BHATTACHARYA S, 1991, P EPE 91 C, V3, P30
[6]   A PRACTICAL APPROACH TO HARMONIC COMPENSATION IN POWER-SYSTEMS - SERIES CONNECTION OF PASSIVE AND ACTIVE-FILTERS [J].
FUJITA, H ;
AKAGI, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (06) :1020-1025
[7]   An approach to harmonic current-free AC/DC power conversion for large industrial loads: The integration of a series active filter with a double-series diode rectifier [J].
Fujita, H ;
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1233-1240
[8]  
GYUGYI L, 1976, P IEEE IAS ANN M, P529
[9]   ACTIVE DAMPING OF RESONANCES IN POWER-SYSTEMS [J].
LE, TN ;
PEREIRA, M ;
RENZ, K ;
VAUPEL, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) :1001-1008
[10]  
Oku K., 1994, Transactions of the Institute of Electrical Engineers of Japan, Part B, V114-B, P234