Accuracy of Intraocular Lens Power Formulas Modified for Patients with Keratoconus

被引:35
|
作者
Kane, Jack X. [1 ]
Connell, Benjamin [1 ,2 ]
Yip, Harry [1 ]
McAlister, James C. [3 ]
Beckingsale, Peter [4 ]
Snibson, Grant R. [2 ]
Chan, Elsie [1 ]
机构
[1] Royal Victorian Eye & Ear Hosp, Melbourne, Vic, Australia
[2] Eye Surg Associates, Melbourne, Vic, Australia
[3] Griffith Univ, Brisbane, Qld, Australia
[4] Terrace Eye Ctr, Brisbane, Qld, Australia
关键词
D O I
10.1016/j.ophtha.2020.02.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power formulas modified specifically for patients with keratoconus (Holladay 2 with keratoconus adjustment and Kane keratoconus formula) compared with normal IOL power formulas (Barrett Universal 2, Haigis, Hoffer Q, Holladay 1, Holladay 2, Kane, and SRK/T). Design: Retrospective consecutive case series. Participants: A total of 147 eyes of 147 patients with keratoconus. Methods: Data from patients with keratoconus who had preoperative IOLMaster biometry were included. A single eye per qualifying patient was randomly selected. The predicted refraction was calculated for each of the formulas and compared with the actual refractive outcome to give the prediction error. Subgroup analysis based on the steepest corneal power measured by biometry (stage 1: <= 48 diopters [D], stage 2: >48 D and <= 53 D, and stage 3: >53 D) was performed. Main Outcome Measure: Prediction error. Results: On the basis of the mean absolute prediction error (MAE), the formulas were ranked as follows: Kane keratoconus formula (0.81 D), SRK/T (1.00 D), Barrett Universal 2 (1.03 D), unmodified Kane (1.05 D), Holladay 1 (1.18 D), unmodified Holladay 2 (1.19 D), Haigis (1.22 D), Hoffer Q (1.30 D), and Holladay 2 with keratoconus adjustment (1.32 D). The Kane keratoconus formula had a statistically significant lower MAE compared with all formulas (P < 0.01). In stage 3 keratoconus, all nonmodified formulas had a hyperopic mean prediction error ranging from 1.72 to 3.02 D. Conclusions: The Kane keratoconus formula was the most accurate formula in this series. The SRK/T was the most accurate of the traditional IOL formulas. All normal IOL formulas resulted in hyperopic refractive outcomes that worsened as the corneal power increased. Suggestions for target refractive aims in each stage of keratoconus are given. (C) 2020 by the American Academy of Ophthalmology
引用
收藏
页码:1037 / 1042
页数:6
相关论文
共 50 条
  • [1] Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 212 : 26 - 33
  • [2] Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Gonzalez-Lubcke, Eduardo
    Kahuam-Lopez, Nicolas
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 354 - 355
  • [3] Reply to Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 355 - 356
  • [4] Accuracy of intraocular lens power formulas in eyes with keratoconus: Multi-center study in Japan
    Yokogawa, Tomohiro
    Mori, Yosai
    Torii, Hidemasa
    Goto, So
    Hasegawa, Yumi
    Kojima, Takashi
    Kamiya, Kazutaka
    Shiba, Takuya
    Miyata, Kazunori
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1839 - 1845
  • [5] Accuracy of intraocular lens power formulas in eyes with keratoconus: Multi-center study in Japan
    Tomohiro Yokogawa
    Yosai Mori
    Hidemasa Torii
    So Goto
    Yumi Hasegawa
    Takashi Kojima
    Kazutaka Kamiya
    Takuya Shiba
    Kazunori Miyata
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1839 - 1845
  • [6] Accuracy of intraocular lens calculations in keratoconus patients
    Vandevenne, M. M. S.
    Webers, V. S. C.
    Berendschot, T. T. J. M.
    Dickman, M.
    Abulafia, A.
    Nuijts, R. M. M. A.
    ACTA OPHTHALMOLOGICA, 2022, 100 : 6 - 6
  • [7] Accuracy of intraocular lens power calculation in eyes with keratoconus
    Kojima, Takashi
    Horai, Rie
    Isogai, Naoki
    Nakamura, Tomoaki
    Tamaoki, Akeno
    Ichikawa, Kazuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Studying the effect of keratoconus severity on the accuracy of intraocular lens power calculation using newer keratoconus-specific formulas
    Hany Ahmed Helaly
    Tamer Moussa Ibrahim
    Mohamed Sobhy Hassan
    Mohamed Sobhy El-mansy
    BMC Ophthalmology, 25 (1)
  • [9] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [10] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384