Impact of image registration surrogates on the planning target volume geometry for bladder radiation therapy

被引:4
|
作者
Kong, Vickie [1 ]
Kwan, Maisie [1 ]
Chen, Susan [1 ]
Moseley, Joanne [1 ]
Craig, Tim [1 ,2 ]
Chung, Peter [1 ,2 ]
Rosewall, Tara [1 ,2 ]
机构
[1] Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
ADAPTIVE RADIOTHERAPY; GUIDED RADIOTHERAPY; CANCER; MARGINS; MOTION; LOCALIZATION; TUMOR;
D O I
10.1016/j.prro.2015.12.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The use of Lipiodol and cone beam computed tomography (CT) has facilitated the generation of patient-specific planning target volumes (PTV) to reduce irradiation of normal tissue. However, injecting Lipiodol to demarcate the target volume is an invasive procedure. Center of bladder (COB) and bladder wall surface (BWS) encompassed by the clinical target volume (CTV) are proposed to be the alternative noninvasive surrogates. This study examines the impact of using these 3 surrogates for image registration on the resultant geometry of patient-specific PTVs. Methods and materials: Twenty bladder cancer patients who had Lipiodol injection before planning CT were included. Lipiodol, CTV, and bladder were delineated on the planning CT. In addition, CTVs were delineated on 5 cone beam CT scans from each patient. Cone beam CT scans were registered to planning CT using Lipiodol, COB, and BWS to generate Lipiodol-PTV, COB-PTV, and BWS-PTV. Using Lipiodol as the reference, the difference in the 2-dimensional/3-dimensional displacement values and the geometry of the resultant PTVs were quantified. Results: A total of 1200 displacement values and 60 volumes were included for analysis. The overall median and standard deviation (SD) of the 3-dimensional displacement (mm) measured by Lipiodol, BWS, and COB are 25 (SD, 15), 24 (SD, 14), and 21 (SD, 15), respectively. Lipiodol-PTV has the smallest mean volume, followed by BWS-PTV and COB-PTV. BWS-PTV was more geometrically similar to Lipiodol PTV when compared with COB-PTV. Six of 20 COB-PTVs who had CTV located at either the dome or the base of the bladder were larger than the corresponding Lipiodol-PTV by more than 20%. Conclusion: Lipiodol is the optimal image registration surrogate for partial bladder radiation therapy. However, for patients who are contraindicated for Lipiodol injection, BWS is the preferred noninvasive surrogate because the derived PTV has a smaller geometric variation from the Lipiodol-PTV when compared with COB, especially when the CTV was located at the dome or the base of the bladder. Crown Copyright (C) 2016 Published by Elsevier Inc. on behalf of the American Society for Radiation Oncology. All rights reserved.
引用
收藏
页码:E187 / E194
页数:8
相关论文
共 50 条
  • [1] Anisotropic Bladder Planning Target Volume in Bladder Radiation Therapy
    Adil, Khaled
    Popovic, Marija
    Cury, Fabio L.
    Faria, Sergio L.
    Duclos, Marie
    Souhami, Luis
    PRACTICAL RADIATION ONCOLOGY, 2019, 9 (01) : 24 - 28
  • [2] IMPACT OF MULTIMODAL IMAGE REGISTRATION AND FUSION ON PLANNING TARGET VOLUME ACROSS TWO ERAS: TRENDS IN PRECISION RADIATION THERAPY
    Hina, Mariam
    Tariq, Maria
    Abbasi, Ahmed Nadeem
    Abrar, Sehrish
    Ali, Nasir
    Hafiz, Asim
    Qureshi, Bilal Mazhar
    PEDIATRIC BLOOD & CANCER, 2023, 70 : S189 - S189
  • [3] Deriving patient-specific planning target volume for partial bladder image guided radiation therapy
    Kong, Vickie
    Rosewall, Tara
    Chen, Susan
    Craig, Tim
    Bristow, Robert
    Milosevic, Michael
    Kwan, Maisie
    Chung, Peter
    PRACTICAL RADIATION ONCOLOGY, 2014, 4 (05) : 323 - 329
  • [4] Planning target volume density impact on treatment planning for lung stereotactic body radiation therapy
    Savanovic, Milovan
    Jaros, Drazan
    Foulquier, Jean-Noel
    ACTA ONCOLOGICA, 2021, 60 (10) : 1296 - 1300
  • [5] Planning Target Volume Management of Uncertainties, Immobilization, image guided and adaptive Radiation Therapy
    Schwahofer, A.
    Jaekel, O.
    RADIOLOGE, 2018, 58 (08): : 736 - 745
  • [6] Is Deformable PET/CT Registration for Contouring Target Volume Superior to Rigid Image Registration in Lung Cancer Radiation Therapy?
    Dincbas, H. F.
    Oksuz, D. C.
    Ergen, S. A.
    Ozuynuk, G.
    Bol, Z.
    Bakir, A.
    Karacam, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S641 - S641
  • [7] Impact of Planning Target Volume Margins and Rectal Distention on Biochemical Failure in Image Guided Radiation Therapy of Prostate Cancer
    Engels, B.
    Soete, G.
    Gevaert, T.
    Storme, G.
    Michielsen, D.
    De Ridder, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S418 - S418
  • [8] The effect of image-guided radiation therapy on the margin between the clinical target volume and planning target volume in lung cancer
    Liang, Jun
    Li, Minghui
    Zhang, Tao
    Han, Wei
    Chen, Dongfu
    Hui, Zhouguang
    Lv, Jima
    Zhang, Zhong
    Zhang, Yin
    Zhang, Liansheng
    Zheng, Rong
    Dai, Jianrong
    Wang, Luhua
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (01): : 30 - 37
  • [9] Anisotropic Bladder Planning Target Volume is Adequate When Using Cone Beam Computed Tomography as a Form of Image Guided Radiation Therapy
    Adil, K.
    Popovic, M.
    Cury, F. L.
    Faria, S.
    Souhami, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E210 - E210
  • [10] Image registration: An essential part of radiation therapy treatment planning
    Rosenman, JG
    Miller, EP
    Tracton, G
    Cullip, TJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (01): : 197 - 205