Risk evaluation on the basis of pressure rate measured by automatic pressure tracking adiabatic calorimeter

被引:6
|
作者
Iwata, Yusaku [1 ]
Koseki, Hiroshi [1 ]
机构
[1] Natl Res Inst Fire & Disaster, Chofu, Tokyo 1828508, Japan
关键词
Thermal decomposition; Automatic pressure tracking adiabatic calorimeter; Pressure rate; Gas production index; Di-tert-butyl peroxide;
D O I
10.1016/j.jhazmat.2008.01.041
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An automatic pressure tracking adiabatic calorimeter (APTAC) had been employed to obtain the thermokinetic and the vapor pressure data during runaway reactions. The APTAC is an adiabatic calorimeter with a large-scale sample mass and low thermal inertia, and is an extremely useful tool for assessing thermal hazards of reactive chemicals. The data obtained by the APTAC are important information for the design of the safe industrial process. The thermodynamics parameters and the gas production were discussed on the basis of the experimental data of various concentrations and weights of di-tert-butyl peroxide (DTBP)/toluene solution for the purpose of investigating the properties of the APTAC data. The thermal decomposition of DTBP was studied on the basis of the temperature data and the pressure data obtained by the APTAC. The activation energy and the frequency factor of DTBP are nearly constant and the same as the literature values in the concentrations between 20 and 60 wt.%. The pressure rise due to gas production is important data for designing the relief vent of a reactor. The time history of the gas production was investigated with various weights and concentrations. The total gas production index, which had the vapor pressure correction, was 1.0 in the decomposition of DTBP. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Thermal risk evaluation of organic peroxide by automatic pressure tracking adiabatic calorimeter
    Iwata, Y.
    Momota, M.
    Koseki, H.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2006, 85 (03) : 617 - 622
  • [2] Thermal risk evaluation of organic peroxide by automatic pressure tracking adiabatic calorimeter
    Y. Iwata
    M. Momota
    H. Koseki
    Journal of Thermal Analysis and Calorimetry, 2006, 85 : 617 - 622
  • [3] Characteristics of heat release measured by automatic pressure tracking adiabatic calorimeter
    Iwata, Y
    Momota, M
    Koseki, H
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 987 - 992
  • [4] The APTAC: A high pressure, low thermal inertia, adiabatic calorimeter
    Chippett, S
    Ralbovsky, P
    Granville, R
    INTERNATIONAL SYMPOSIUM ON RUNAWAY REACTIONS, PRESSURE RELIEF DESIGN, AND EFFLUENT HANDLING, 1998, : 81 - 108
  • [5] CONSTRUCTION OF AN ADIABATIC CALORIMETER WORKABLE UNDER CONSTANT HIGH-PRESSURE.
    Oguni, Masaharu
    Watanabe, Kazuo
    Matsuo, Takasuke
    Suga, Hiroshi
    Seki, Syuzo
    Bulletin of the Chemical Society of Japan, 1982, 55 (01) : 77 - 84
  • [6] CONSTRUCTION OF AN ADIABATIC HIGH-PRESSURE CALORIMETER USING HELIUM GAS FOR PRESSURIZATION
    YAMAMURO, O
    OGUNI, M
    MATSUO, T
    SUGA, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (04) : 1269 - 1275
  • [7] Development of a quasi-adiabatic calorimeter for the determination of the water vapor pressure curve
    Mokdad, S.
    Georgin, E.
    Hermier, Y.
    Sparasci, F.
    Himbert, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07):
  • [8] Development of an adiabatic calorimeter for simultaneous measurement of enthalpy and volume under high pressure
    Takahara, S
    Yamamuro, O
    Ishikawa, M
    Matsuo, T
    Suga, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01): : 185 - 192
  • [9] Automatic tracking of low-pressure vortex
    Makihara, T
    Kida, S
    Miura, H
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2002, 71 (07) : 1622 - 1625
  • [10] ANKLE BLOOD-PRESSURE MEASURED BY AUTOMATIC OSCILLOTONOMETRY - A COMPARISON WITH DOPPLER PRESSURE MEASUREMENTS
    SHEARMAN, CP
    SIMMS, MH
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1988, 70 (04) : 257 - 257