Bio-Composite Materials Precursor to Chitosan in the Development of Electrochemical Sensors: A Critical Overview of Its use with Micro-Pollutants and Heavy Metals Detection

被引:8
|
作者
Sarikokba [1 ]
Tiwari, Diwakar [1 ]
Prasad, Shailesh Kumar [2 ]
Kim, Dong Jin [3 ]
Choi, Suk Soon [4 ]
Lee, Seung-Mok [5 ]
机构
[1] Mizoram Univ, Sch Phys Sci, Dept Chem, Aizawl 796004, India
[2] Natl Inst Technol, Dept Chem, Jamshedpur 831043, Bihar, India
[3] Hallym Univ, Dept Environm Sci & Biotechnol, Chunchon 24252, South Korea
[4] Semyung Univ, Dept Biol & Environm Engn, Jecheon 27136, South Korea
[5] Catholic Kwandong Univ, Dept Hlth & Environm, Kangnung 25601, South Korea
来源
APPLIED CHEMISTRY FOR ENGINEERING | 2020年 / 31卷 / 03期
基金
新加坡国家研究基金会;
关键词
Electrochemical sensor; Bio-composite materials; Chitosan; Detection limit; Glassy carbon electrode; Heavy metals; Micro-pollutants; GLASSY-CARBON ELECTRODE; ANODIC-STRIPPING VOLTAMMETRY; REDUCED GRAPHENE OXIDE; ENHANCED AMPEROMETRIC DETECTION; HIGHLY SELECTIVE DETECTION; BISPHENOL-A; WASTE-WATER; GOLD NANOPARTICLES; HYDROGEN-PEROXIDE; SENSING PLATFORM;
D O I
10.14478/ace.2020.1034
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The role of nano bio-composites precursor to chitosan are innumerable and are known for having different applications in various branches of physical sciences. The application to the sensor development is relatively new, where only few literature works are available to address the specific and critical analysis of nanocomposites in the subject area. The bio-composites are potential and having greater affinity towards the heavy metals and several micro-pollutants hence, perhaps are having wider implications in the low or even trace level detection of the pollutants. The nano-composites could show good selectivity and suitability for the detection of the pollutants as they are found in the complex matrix. However, the greater challenges are associated using the bio-composites, since the biomaterials are prone to be oxidized or reduced at an applied potential and found to be a hinderance for the detection of target pollutants. In addition, the materials could proceed with a series of electrochemical reactions, which could produce different by-products in analytical applications, resulting in several complex phenomena in electrochemical processes. Therefore, this review addresses critically various aspects of an evaluation of nano bio-composite materials in the electrochemical detection of heavy metals and micro-pollutants from aqueous solutions.
引用
收藏
页码:237 / 257
页数:21
相关论文
empty
未找到相关数据