Soil texture and salinity effects on calibration of TDR300 dielectric moisture sensor

被引:17
|
作者
Kargas, George [1 ]
Ntoulas, Nikolaos [2 ]
Nektarios, Panayiotis A. [2 ]
机构
[1] Agr Univ Athens, Dept Nat Resources Management & Agr Engn, Div Water Resources Management, Lab Agr Hydraul, GR-11855 Athens, Greece
[2] Agr Univ Athens, Dept Crop Sci, Lab Floriculture & Landscape Architecture, GR-11855 Athens, Greece
关键词
electrical conductivity; dielectric sensors; permittivity; TIME-DOMAIN REFLECTOMETRY; WATER-CONTENT DETERMINATION; ELECTROMAGNETIC DETERMINATION; ELECTRICAL-CONDUCTIVITY; LABORATORY CALIBRATION; MEDIA; TEMPERATURE; PERFORMANCE; FREQUENCY; PROBE;
D O I
10.1071/SR13009
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Newly developed sensors have simplified real-time determination of soil water content (theta(m)). Although the TDR300 is one of the most recent dielectric sensors, little is known with regard to the accuracy and dependency of its measurements of soil type and other environmental factors. In this study, the performance of TDR300 was investigated using liquids of known dielectric properties and a set of porous media with textures ranging from sandy to clayey. The experiments were conducted in the laboratory by mixing different amounts of water with each soil to obtain a sufficient range of soil water contents. For sand, the calculated permittivity values (epsilon(r)) correlated adequately with Topp's equation derived for time domain reflectometry. However, for the remaining inorganic porous media, er values were overestimated compared with those resulting from Topp's equation, especially for water contents exceeding 0.2 cm(3)/cm(3). The results suggested that the relationship between theta(m) and root epsilon(r) was strongly linear (0.953< r(2) <0.998). The most accurate results were provided by soil-specific calibration equations, which were obtained by the multi-point calibration equation. However, two-point calibration equations determined water content in all tested soils reasonably well, except for clay soil. A linear regression equation was developed that correlated the slope of the relationship theta(m)-root epsilon(r) with bulk soil electrical conductivity (EC). The regression slope was influenced more by soil EC than by soil texture. Also, TDR300 response was investigated in bi-layered systems (liquid-air and saturated porous media-air). In a bi-layered sensing volume characterised by strongly contrasting dielectric values, the appropriate bulk permittivity values for water and loam soil were determined by arithmetic rather than refractive index averaging, while for butanol and sand these values remained somewhere between the two averaging schemes, indicating that the upward infiltration calibration technique is inappropriate for the TDR300 sensor. Soil solute EC, as determined by measurements conducted in liquids and sand, significantly affected permittivity values at much lower levels than the limit of EC < 2 dS/m, as suggested by the manufacturer. However, the relationship theta(m)-root epsilon(r) remained linear up to EC 2 dS/m, which corresponded to a bulk soil EC value of 0.6 dS/m. By contrast, for EC values >2 dS/m, the relationship theta(m)-root epsilon(r) was not linear, and, thus the TDR300 device calibration became increasingly difficult. Therefore, rather than operating as a time domain device, TDR300 operates as a water content reflectometer type device.
引用
收藏
页码:330 / 340
页数:11
相关论文
共 50 条
  • [1] Salinity Effects on the Fieldscout TDR 300 Soil Moisture Meter Readings
    Benor, Michael
    Levy, Guy J.
    Mishael, Yael
    Nadler, Arie
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2013, 77 (02) : 412 - 416
  • [2] TDR Calibration for Soil Moisture Measurements Using a Spectroscopic Dielectric Model
    Mironov, V. L.
    Kosolapova, L. G.
    Muzalevskiy, K. V.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 311 - 314
  • [3] Improving the calibration of dielectric TDR soil moisture determination taking into account the solid soil
    Malicki, MA
    Plagge, R
    Roth, CH
    EUROPEAN JOURNAL OF SOIL SCIENCE, 1996, 47 (03) : 357 - 366
  • [4] Operative Calibration Methodology of a TDR Sensor for Soil Moisture Monitoring under Irrigated Crops
    H. Quinones
    P. Ruelle
    Subsurface Sensing Technologies and Applications, 2001, 2 (1): : 31 - 45
  • [5] Performance of TDR calibration models as affected by soil texture
    Ponizovsky, AA
    Chudinova, SM
    Pachepsky, YA
    JOURNAL OF HYDROLOGY, 1999, 218 (1-2) : 35 - 43
  • [6] Performance of TDR calibration models as affected by soil texture
    Institute of Soil Science and Photosynthesis, Academy of Sciences, Pushchino, Moscow Region, 142292, Russia
    不详
    不详
    J. Hydrol., 1-2 (35-43):
  • [7] Comparison of three calibration procedures for TDR soil moisture sensors
    Quinones, H
    Ruelle, P
    Nemeth, I
    IRRIGATION AND DRAINAGE, 2003, 52 (03) : 203 - 217
  • [8] Application of the TDR Soil Moisture Sensor for Terramechanical Research
    Pytka, Jaroslaw
    Budzynski, Piotr
    Kaminski, Mariusz
    Lyszczyk, Tomasz
    Jozwik, Jerzy
    SENSORS, 2019, 19 (09)
  • [9] Soil moisture calibration of a TDR multilevel probe in gravely soils
    Frueh, WT
    Hopmans, JW
    SOIL SCIENCE, 1997, 162 (08) : 554 - 565