Yeast-fouling effects in cross-flow microfiltration with periodic reverse filtration

被引:22
|
作者
Mores, WD [1 ]
Davis, RH [1 ]
机构
[1] Univ Colorado, Dept Chem Engn, Boulder, CO 80309 USA
关键词
D O I
10.1021/ie020421k
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Yeast-foulant removal via reverse filtration from cellulose acetate microfiltration membranes was observed in situ using a direct visual observation (DVO) microvideo system. The sizes of the foulant blockages increased with filtration time as cells aggregated on the membrane surface and in the suspension. Coupling of the DVO-determined fractional coverage data with the experimentally determined membrane fluxes indicates that the flow through the cleaned portions of the membranes is nearly straight-through (i.e., little to no radial flow underneath foulant blockages), and the flux through the yeast-covered fraction with backpulsing is over twice the long-term fouled membrane flux without backpulsing. Cell rupture caused by reverse filtration at transmembrane pressures of 3 psi or more led to increased irreversible fouling of the membranes, with scanning electron microscopy pictures revealing a thin blanketing layer of foulant, which is most likely the contents of ruptured cells.
引用
收藏
页码:130 / 139
页数:10
相关论文
共 50 条
  • [1] Semiempirical modeling of cross-flow microfiltration with periodic reverse filtration
    Howard P. Isermann Dept. Chem. Eng., Rensselaer Polytechnic Institute, Troy, NY 12180, United States
    Ind Eng Chem Res, 9 (2920-2928):
  • [2] Semiempirical modeling of cross-flow microfiltration with periodic reverse filtration
    Mallubhotla, H
    Belfort, G
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (09) : 2920 - 2928
  • [3] CROSS-FLOW MICROFILTRATION WITH HIGH-FREQUENCY REVERSE FILTRATION
    REDKAR, SG
    DAVIS, RH
    AICHE JOURNAL, 1995, 41 (03) : 501 - 508
  • [4] Modeling of fouling in cross-flow microfiltration of suspensions
    Weeranoppanant, Nopphon
    Amar, Levy I.
    Tong, Evelyn
    Faria, Monica
    Hill, Michael I.
    Leonard, Edward F.
    AICHE JOURNAL, 2019, 65 (01) : 207 - 213
  • [5] MECHANISMS AND CONTROL OF FOULING IN CROSS-FLOW MICROFILTRATION
    WENTEN, IG
    FILTRATION & SEPARATION, 1995, 32 (03): : 252 - 253
  • [6] MODELING OF FOULING OF CROSS-FLOW MICROFILTRATION MEMBRANES
    DAVIS, RH
    SEPARATION AND PURIFICATION METHODS, 1992, 21 (02): : 75 - 126
  • [7] CROSS-FLOW MICROFILTRATION OF YEAST SUSPENSIONS
    DAVIS, RH
    REDKAR, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 37 - BIOT
  • [8] Filtration characteristics and membrane fouling in cross-flow microfiltration of BSA/dextran binary suspension
    Hwang, Kuo-Jen
    Sz, Pan-Yu
    JOURNAL OF MEMBRANE SCIENCE, 2010, 347 (1-2) : 75 - 82
  • [9] CROSS-FLOW MICROFILTRATION (CMF) OF YEAST AND BEER - FILTRATION WITHOUT USE OF KIESELGUHR
    WAGNER, D
    DONHAUSER, S
    WALLA, G
    JOURNAL OF THE INSTITUTE OF BREWING, 1987, 93 (03) : 164 - 164
  • [10] FOULING DURING CROSS-FLOW MICROFILTRATION OF MICROBIAL SUSPENSIONS
    DAVIS, RH
    SHAMS, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 143 - IAEC