Numerical Study on Performance Optimization of an Energy-Saving Insulated Window

被引:8
|
作者
Wang, Zhiqiang [1 ,2 ]
Tian, Qi [1 ]
Jia, Jie [1 ]
机构
[1] Taiyuan Univ Technol, Dept Bldg Environm & Energy Applicat Engn, Daxue St 209, Jinzhong 030600, Peoples R China
[2] Taiyuan Inst Technol, Dept Environm & Safety Engn, Xinlan Rd 31, Taiyuan 030008, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
energy-saving insulated window; energy consumption properties; window-to-wall ratio; energy-saving standard; temperature index; heat transfer coefficient; response surface methodology;
D O I
10.3390/su13020935
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Window energy consumption has become a key factor in designing buildings with optimal energy efficiency. To that end, herein, the use of an energy-saving insulated window (ESIW) is proposed, particularly for winter heat conservation. DeST software was used to evaluate the energy consumption properties of a house with an ESIW-structure window, as well as that of six other window structures currently on the market. The results were subsequently compared. Furthermore, a series of numerical simulations were carried out using Airpak software to investigate the insulation performance of four ESIW models (A, B, C, and D) under different influencing factors. Finally, the response surface method (RSM) was used to obtain the optimal ESIW structure installation conditions and the weight of each factor. The data shows that houses with ESIW-structure windows exhibit a more suitable indoor natural temperature; less heating load, cooling load, and cumulative annual load; and a more feasible price-load ratio than other energy-saving windows. Furthermore, the average temperature gradually decreased in response to decreasing the electric heater power and energy-saving standard, and increasing the heat transfer coefficient (HTC) and window-to-wall ratio (WWR). Thus, as the energy-saving standard (ESS) increases, the importance of the WWR increases in parallel. This study puts forward an HTC prediction formula that is applicable to different conditions. The optimal thermal efficiency conditions consisted of HTC = 1.07 W/m(2) x K, WWR = 0.26, and an ESS of 75%. This study demonstrates that the ESIW system has optimal energy-saving properties and broad adaptability and operability, which can be applied in building insulation as a key insulation component.
引用
收藏
页码:1 / 25
页数:25
相关论文
共 50 条
  • [1] Performance study of new energy-saving gas stove and its optimization
    Zhang, Jinhong
    Dai, Xuewei
    Yang, Miao
    Xie, Ning
    Zhang, Ruxin
    Liu, Ying
    Wu, Jiang
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 1249 - 1252
  • [2] The performance of a novel window with energy-saving potential in cold regions of China
    Wang, Zhiqiang
    Akhlaghi, Yousef G.
    Tian, Qi
    Cheng, Yuanda
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (01) : 245 - 264
  • [3] Researchers developing energy-saving window film
    Shaw, Mark, 1600, McGraw-Hill Companies (275):
  • [4] Numerical Study on Energy-Saving Performance of a New Type of Phase Change Material Room
    Ye, Rongda
    Fang, Xiaoming
    Zhang, Zhengguo
    ENERGIES, 2021, 14 (13)
  • [5] A LOW-COST, ENERGY-SAVING WINDOW SYSTEM
    MORRONE, T
    ENERGY, 1980, 5 (03) : 207 - 215
  • [6] Empirical Study on Annual Energy-Saving Performance of Energy Performance Contracting in China
    Ruan, Hongquan
    Gao, Xin
    Mao, Chaoxuan
    SUSTAINABILITY, 2018, 10 (05)
  • [7] Energy-saving optimization for intelligent pumps based on performance reliability restriction
    Huang, Bochao
    Wang, Shaoping
    Meng, Yixuan
    Shi, Jian
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2013, 39 (04): : 559 - 563
  • [8] Energy-saving optimization of air conditioning terminal device based on numerical simulation
    Yan, Jun-Wei
    Liu, Yang
    Zhou, Xuan
    Kang, Ying-Zi
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2012, 40 (04): : 144 - 149
  • [9] Energy-saving optimization of urban drainage system based on pump performance
    Hou, Shufang
    Li, Dewei
    Xi, Yugeng
    Cen, Lihui
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 308 - 313
  • [10] PERFORMANCE EVALUATION OF ENERGY-SAVING MEASURES
    PIETTE, MA
    ANDERSSON, B
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1988, 30 (06): : 34 - 39