Endodontic Length Measurements Using Different Modalities: An In Vitro Study

被引:4
|
作者
Phuc Ngoc Nguyen [1 ]
Khoa Van Pham [1 ]
机构
[1] Univ Med & Pharm Ho Chi Minh City, Fac Odontostomatol, Dept Operat Dent & Endodont, 652 Nguyen Trai St,Ward 11,Dist 5, Ho Chi Minh City 700000, Vietnam
关键词
3D Endo; cone-beam computed tomography; electronic apex locator; endodontics; root canal length;
D O I
10.4103/jispcd.JISPCD_357_20
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to investigate and compare the accuracy of the 3D Endo software, conventional CBCT software Romexis Viewer, and the EAL E-Pex Pro in WL determination. Materials and Methods: Three hundred and two root canals in 110 intact human extracted molars were accessed. The actual lengths (ALs) were measured. Root canal lengths were measured using 3D Endo with proposed length (3D-PL) by software, correct length (3D-CL), Romexis Viewer, and the E-Pex Pro. The percentages of the measurements in the range of +/- 0.5 mm to the AL were compared using the Fisher's exact test. The paired t test and Bland-Altman plots were calculated to detect the agreement of the four methods with the AL measurements. The statistical significance was set at P<0.05. Results: The accuracies in the range of +/- 0.5 mm to the AL were 83.8%, 86.7%, 48.3%, and 99.7% for 3D-PL, 3D-CL, Romexis Viewer, and E-PexPro, respectively. There were agreements between 3D-PL and Romexis Viewer with the AL measurements. Conclusion: The CBCT measurements using 3D Endo with the proposed length by the software and Romexis Viewer with the voxel size of 0.15 mm agreed with the AL measurements of the root canals.
引用
收藏
页码:752 / 758
页数:7
相关论文
共 50 条
  • [1] Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufactureran in vitro study
    Haupt, Franziska
    Huelsmann, M.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (09) : 3107 - 3112
  • [2] Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer—an in vitro study
    Franziska Haupt
    M Hülsmann
    Clinical Oral Investigations, 2018, 22 : 3107 - 3112
  • [3] IN VITRO COMPARISON OF THREE DIFFERENT IMAGE RECEPTORS FOR DETERMINING THE LENGTH OF ENDODONTIC FILES
    Iovan, Gianina
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2015, 119 (01): : 256 - 256
  • [4] In vitro comparison of three different image receptors for determining the length of endodontic files
    Ilhan, Betul
    Akcay, Ilgin
    Dundar, Nesrin
    JOURNAL OF DENTAL SCIENCES, 2014, 9 (04) : 345 - 350
  • [5] Endodontic length measurements using cone beam computed tomography with dedicated or conventional software at different voxel sizes
    Khoa Van Pham
    Scientific Reports, 11
  • [6] Endodontic length measurements using cone beam computed tomography with dedicated or conventional software at different voxel sizes
    Van Pham, Khoa
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] A Comparative Examination of Cyclic Fatigue and Fragment Length of Three Different Types of Endodontic Rotary Files: An In Vitro Study
    Saleh, Hanaa Abduljabbar
    Abdulhameed, Othman Husham
    DENTAL HYPOTHESES, 2022, 13 (02): : 49 - 52
  • [8] Diagnostic efficacy of 3 imaging modalities in the detection of fractured endodontic instruments: an in vitro study
    Madian, Sara
    Gaweesh, Yousria
    El-Badawy, Fatma
    Genena, Salma
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2023, 135 (02): : 303 - 311
  • [9] Discrepancies in clavicle-to-carotid bifurcation length measurements for transcarotid artery revascularization using different imaging modalities
    Wu, Winona W.
    Yadavalli, Sai Divya
    Lu, Jinny J.
    Cheng, Jane J.
    Liang, Patric
    Dansey, Kirsten
    Stangenberg, Lars
    Wyers, Mark C.
    Hamdan, Allen D.
    Schermerhorn, Marc L.
    JOURNAL OF VASCULAR SURGERY, 2023, 78 (06) : 1439 - +
  • [10] Can ultrasonography be used to determine working length in endodontic treatment? An in vitro study
    Eren, Irem
    Sariyilmaz, Oznur
    Eren, Hakan
    Sariyilmaz, Evren
    Uslu, Gulsah
    ODONTOLOGY, 2024, 112 (02) : 453 - 459