Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography

被引:47
|
作者
Keane, P. A. [1 ]
Mand, P. S. [2 ]
Liakopoulos, S. [3 ]
Walsh, A. C. [1 ]
Sadda, S. R. [1 ]
机构
[1] Univ So Calif, Keck Sch Med, Doheny Eye Inst, Doheny Image Reading Ctr, Los Angeles, CA 90033 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Univ Cologne, Ctr Ophthalmol, Dept Vitreoretinal Surg, D-5000 Cologne 41, Germany
关键词
DIABETIC MACULAR EDEMA; SEGMENTATION; SUBANALYSIS; ARTIFACTS; ERROR;
D O I
10.1136/bjo.2008.155846
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To report the frequency and severity of retinal thickness measurement errors in a Fourier domain optical coherence tomography (FDOCT) device, Cirrus OCT. Methods: Data from 209 eyes undergoing Cirrus OCT imaging with the Macular Cube protocol were collected. For each eye, the position of the automated retinal boundary lines used by the Cirrus OCT software for thickness calculations was assessed using a 6-point categorical scale. The presence of errors was correlated with various parameters including: retinal morphological features and disease diagnosis. Results: Errors of retinal boundary detection were observed in 57.5% of eyes but were severe in only 9.6% of eyes. The identification of subretinal fluid, subretinal tissue, pigment epithelium detachment or a diagnosis of choroidal neovascularisation was associated with more severe errors. Retinal cysts or a diagnosis of retinal vascular disease were less likely to be associated with significant error. Conclusions: Retinal thickness measurement errors appear to occur less frequently with Fourier domain OCT (Cirrus OCT), but segmentation errors remain a concern, particularly in assessment of eyes with structurally complex retinal disease. With the recent release of multiple FDOCT systems, assessment of segmentation error may be an important factor in determining the relative merits of these systems.
引用
收藏
页码:1461 / 1467
页数:7
相关论文
共 50 条
  • [1] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293
  • [2] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125
  • [3] Effect of Myopia on Retinal Nerve Fibre Layer Thickness Measurements by Cirrus HD Optical Coherence Tomography
    Singh, Divya
    Pathak, Mona
    Dada, Tanuj
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [6] Prospective Comparison of Cirrus and Stratus Optical Coherence Tomography for Quantifying Retinal Thickness
    Kiernan, Daniel F.
    Hariprasad, Seenu M.
    Chin, Eric K.
    Kiernan, Claire L.
    Rago, James
    Mieler, William F.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) : 267 - 275
  • [7] Reproducibility of foveal thickness measurements obtained by retinal thickness analyzer (RTA) compared to optical coherence tomography (OCT).
    Neubauer, AS
    Thiel, M
    Niederdellmann, C
    Bechmann, M
    Ulbig, MW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S173 - S173
  • [8] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [9] Automated measurements of retinal thickness with optical coherence tomography - Reply
    Ray, R
    Stinnett, SS
    Jaffe, GJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 351 - 351
  • [10] Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography
    Wu, Ziqiang
    Vazeen, Matti
    Varma, Rohit
    Chopra, Vikas
    Walsh, Alexander C.
    LaBree, Laurie D.
    Sadda, Srinivas R.
    OPHTHALMOLOGY, 2007, 114 (08) : 1505 - 1512