ECG-Edited Middiastolic Phase Reconstruction Improves Image Quality at 64-MDCT Coronary Angiography of Patients with Atrial Fibrillation

被引:19
|
作者
Matsumoto, Hidenari [1 ]
Kondo, Takeshi [2 ,3 ]
Watanabe, Satoshi
Kikumoto, Rikiya [4 ]
Shimada, Toshihiko [5 ]
Hiraoka, Yuji [1 ]
Ueda, Kinzo [1 ]
机构
[1] Rakuwakai Otowa Hosp, Ctr Cardiovasc, Yamashina Ku, Kyoto 6078062, Japan
[2] Takase Clin, Dept Cardiol, Takasaki, Gunma, Japan
[3] Kusatsu Heart Ctr, Dept Cardiol, Kusatsu, Japan
[4] Rakuwakai Otowa Hosp, Dept Radiol Technol, Kyoto 6078062, Japan
[5] Rakuwakai Otowa Hosp, Dept Gen Internal Med, Kyoto 6078062, Japan
关键词
atrial fibrillation; coronary CT angiography; ECG editing; middiastolic phase reconstruction;
D O I
10.2214/AJR.07.3944
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aims of this study were to evaluate image quality at the absolute middiastolic and absolute end-systolic phases of 64-MDCT coronary angiography of patients with atrial fibrillation and to compare the findings with those among patients in sinus rhythm. SUBJECTS AND METHODS. Nineteen consecutively registered patients with atrial fibrillation and 19 patients in sinus rhythm taking heart-rate-lowering agents as needed underwent MDCT. Images were reconstructed with a half-scan reconstruction algorithm after ECG editing (deletion of short R-R intervals, insertion of additional temporal windows into the middiastolic phase of long R-R intervals, and shift of R points). We used a 5-point scale (4, no motion artifacts; 0, unevaluable) to evaluate motion artifacts and coronary artery image discontinuities greater than 1 mm on the curved multiplanar reconstruction images. Each coronary artery image with a motion score of 2 or greater for all segments and with 2 or fewer discontinuities was considered acceptable for diagnosis. RESULTS. Middiastolic images of patients with atrial fibrillation showed fewer motion artifacts and image discontinuities than did end-systolic images of patients with atrial fibrillation. Despite greater heart rate variability under the condition of similar mean heart rates in patients with atrial fibrillation, motion artifacts and image discontinuities on middiastolic images were not significantly different from those on sinus rhythm images. Acceptable quality was achieved on 91% of middiastolic atrial fibrillation images and 93% of sinus rhythm images. CONCLUSION. ECG-edited middiastolic atrial fibrillation images with aggressive heart rate control were of better quality than end-systolic images in patients with atrial fibrillation. The diagnostic image quality of the middiastolic images was comparable with that of sinus rhythm images.
引用
收藏
页码:1659 / 1666
页数:8
相关论文
共 50 条
  • [1] 64-MDCT Coronary Angiography of Patients With Atrial Fibrillation: Influence of Heart Rate on Image Quality and Efficacy in Evaluation of Coronary Artery Disease
    Yang, Lin
    Zhang, Zhaoqi
    Fan, Zhanming
    Xu, Chao
    Zhao, Lei
    Yu, Wei
    Yan, Zixu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) : 795 - 801
  • [2] Optimizing coronary artery imaging in patients with atrial fibrillation with ECG-gated 64-MDCT
    Strub, William M.
    Vagal, Achala
    Meyer, Cristopher
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (01) : W50 - W51
  • [3] Automated Cardiac Phase Selection with 64-MDCT Coronary Angiography
    Joemai, Raoul M. S.
    Geleijns, Jacob
    Veldkamp, Wouter J. H.
    de Roos, Albert
    Kroft, Lucia J. M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) : 1690 - 1697
  • [4] Comparison of Radiation Dose and Image Quality: 320-MDCT Versus 64-MDCT Coronary Angiography
    Khan, Atif
    Khosa, Faisal
    Nasir, Khurram
    Yassin, Aya
    Clouse, Melvin E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) : 163 - 168
  • [5] Inverse-direction scanning improves the image quality of whole carotid CT angiography with 64-MDCT
    Kuroda, Yuuki
    Hosoya, Takaaki
    Oda, Atsuko
    Ooki, Nozomi
    Toyoguchi, Yuuki
    Murakami, Misako
    Kanoto, Masafumi
    Sugawara, Chisato
    Honma, Tsuguo
    Sugai, Yukio
    Nemoto, Kenji
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : 749 - 754
  • [6] Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: A phantom study
    Horiguchi, Jun
    Kiguchi, Masao
    Fujioka, Chikako
    Shen, Yun
    Arie, Ryuichi
    Sunasaka, Kenichi
    Ito, Katsuhide
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 315 - 320
  • [7] 64-MDCT for diagnosis of aortic regurgitation in patients referred to CT coronary angiography
    Feuchtner, Gudrun M.
    Dichtl, Wolfgang
    Mueller, Silvana
    Jodocy, Daniel
    Schachner, Thomas
    Klauser, Andrea
    Bonatti, Johannes O.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : W1 - W7
  • [8] Prospective Coronary CT Angiography 128-MDCT Versus Retrospective 64-MDCT: Improved Image Quality and Reduced Radiation Dose
    Duarte, Ricardo
    Fernandez, Gabriel
    Castellon, Daniel
    Costa, Joao C.
    HEART LUNG AND CIRCULATION, 2011, 20 (02): : 119 - 125
  • [9] 256-Slice coronary computed tomographic angiography in patients with atrial fibrillation: optimal reconstruction phase and image quality
    Oda, Seitaro
    Honda, Keiichi
    Yoshimura, Akira
    Katahira, Kazuhiro
    Noda, Katsuo
    Oshima, Shuichi
    Yuki, Hideaki
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 55 - 63
  • [10] 256-Slice coronary computed tomographic angiography in patients with atrial fibrillation: optimal reconstruction phase and image quality
    Seitaro Oda
    Keiichi Honda
    Akira Yoshimura
    Kazuhiro Katahira
    Katsuo Noda
    Shuichi Oshima
    Hideaki Yuki
    Masafumi Kidoh
    Daisuke Utsunomiya
    Takeshi Nakaura
    Tomohiro Namimoto
    Yasuyuki Yamashita
    European Radiology, 2016, 26 : 55 - 63