Tomography experiment of an integrated circuit specimen using 3 MeV electrons in the transmission electron microscope

被引:12
|
作者
Zhang, Hai-Bo [1 ]
Zhang, Xiang-Liang
Wang, Yong
Takaoka, Akio
机构
[1] Xi An Jiao Tong Univ, Dept Elect Sci & Technol, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Phys Elect & Devices Minist Educ, Xian 710049, Peoples R China
[3] Osaka Univ, Res Ctr Ultrahigh Voltage Elect Microscopy, Suita, Osaka 5650871, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2007年 / 78卷 / 01期
基金
中国国家自然科学基金;
关键词
D O I
10.1063/1.2409864
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO2 film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view of elastic scattering of electrons, showing that linear attenuation of the logarithmic electron transmission still holds valid for effective specimen thicknesses up to 5 mu m under 2 MV accelerating voltages. Electron tomography of a micron-order thick integrated circuit specimen including the Cu/via interconnect was then tried with 3 MeV electrons in the ultra-HVEM. Serial projection images of the specimen tilted at different angles over the range of +/- 90 S were acquired, and 3D reconstruction was performed with the images by means of the IMOD software package. Consequently, the 3D structures of the Cu lines, via and void, were revealed by cross sections and surface rendering. (c) 2007 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Parallax measurements of integrated circuit interconnects using a scanning transmission electron microscope
    Levine, ZH
    Gao, JJ
    Neogi, S
    Levin, TM
    Scott, JH
    Grantham, S
    JOURNAL OF APPLIED PHYSICS, 2003, 93 (04) : 2193 - 2197
  • [2] Automated electron microscope tomography using robust prediction of specimen movements
    Mastronarde, DN
    JOURNAL OF STRUCTURAL BIOLOGY, 2005, 152 (01) : 36 - 51
  • [3] Measurement of specimen thickness by using electron holography and electron dynamic calculation with a transmission electron microscope
    Wang, YG
    Liu, HR
    Yang, QB
    Zhang, Z
    CHINESE PHYSICS LETTERS, 2003, 20 (03) : 389 - 391
  • [4] USE OF SLOW ELECTRONS IN A TRANSMISSION ELECTRON MICROSCOPE
    VERTSNER, VN
    SHCHETNE.YF
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1968, 32 (06): : 923 - &
  • [5] Development of tomography-transmission electron microscope (TEM) specimen holder stable under acoustic disturbances
    Bataineh, Khaled
    BUILDING ACOUSTICS, 2021, 28 (04) : 327 - 343
  • [6] Electron tomography for integrated circuit analysis
    不详
    PHOTONICS SPECTRA, 2006, 40 (10) : 95 - 96
  • [7] Measurement of fogging electrons present in scanning electron microscope specimen chamber
    Morimoto, Kentaro
    Ito, Yuka
    Gauvin, Raynald
    Kotera, Masatoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59
  • [8] IMPROVEMENT IN METAL SPECIMEN PREPARATION FOR TRANSMISSION ELECTRON MICROSCOPE STUDIES
    KUSHNER, JB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (01): : 128 - &
  • [9] Electron tomography in an ultrahigh voltage electron microscope with 360°-tilt specimen holder
    Zhang, HB
    Murakami, T
    Takaoka, A
    Miyauchi, K
    ELECTRON MICROSCOPY 1998, VOL 1: GENERAL INTEREST AND INSTRUMENTATION, 1998, : 297 - 298
  • [10] ELECTRON-MICROSCOPE STUDY OF ANOMALOUS TRANSMISSION OF ELECTRONS IN ALUMINUM UP TO 3 MV
    FUJITA, H
    SUMIDA, N
    TABATA, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1973, 35 (01) : 224 - 229