Experimental investigation of synchrotron and Bremsstrahlung dose at lithography beam line of Indus-2 SRS

被引:0
|
作者
Nayak, M. K. [1 ]
Sahani, P. K. [2 ]
Khare, Mukesh [2 ]
Sahu, T. K. [1 ]
Haridas, P. [2 ]
Dev, Vipin [2 ]
Dashora, S. [1 ]
Dhamgaye, Vishal [3 ]
Haridas, G. [1 ]
Sarkar, P. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Hlth Phys, Mumbai 400085, Maharashtra, India
[2] RRCAT, Indus Operat & Accelerator Phys Design Div, Indore 452013, India
[3] RRCAT, Indus Synchrotron Utilisat Div, Indore 452013, India
关键词
Synchrotron radiation; Bremsstrahlung radiation; SR beam line-07; Ion chamber;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Measurement was performed during the initial trial operation of Lithography beam line. (BL-07) of Indus-2 SRS. Transmission of SR through the beam line was optimized by providing bump to electron beam, prior to the measurement. Thin window ion chamber was used for SR measurement in direct beam. Ion current is converted to exposure rate using a calibration factor obtained with respect to Co-60 source. 6 mm thick Cu absorber was used for eliminating SR contribution during BR dose measurement. The exposure rates obtained are 3.83x10(3) Gy/h/mA for SR and 4.2x10(-4) Gy/h/mA for BR. Energy of bremsstrahlung radiation was also experimentally evaluated using attenuation technique. Details of these measurement and results are presented.
引用
收藏
页码:829 / 831
页数:3
相关论文
共 50 条
  • [1] Status of The Indian SRS Indus-2
    Sahni, V. C.
    FRONTIERS IN PHYSICS-BOOK, 2009, 1150 : 180 - 187
  • [2] Design of synchrotron radiation interferometer (SRI) for beam size measurement at visible diagnostics beamline in Indus-2 SRS
    Garg, Akash Deep
    Modi, M. H.
    Puntambekar, T. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 902 : 164 - 172
  • [3] Evaluation of ozone concentration for a white beam line hutch at Indus-2 synchrotron radiation source
    Khan, Saleem
    Nayak, M. K.
    Haridas, G.
    Sarkar, P. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2012, 50 (11) : 840 - 842
  • [4] Synchrotron radiation source INDUS-2
    Singh, G
    Sahoo, GK
    Angal, D
    Singh, AB
    Ghodke, AD
    Kant, P
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1997, 35 (03) : 183 - 192
  • [5] Synchrotron radiation sources INDUS-1 and INDUS-2
    D D Bhawalkar
    G Singh
    R V Nandedkar
    Pramana, 1998, 50 : 467 - 484
  • [6] Synchrotron radiation sources INDUS-1 and INDUS-2
    Bhawalkar, DD
    Singh, G
    Nandedkar, RV
    PRAMANA-JOURNAL OF PHYSICS, 1998, 50 (06): : 467 - 484
  • [7] Measurement of parameters in Indus-2 synchrotron radiation source
    Ghodke, A. D.
    Husain, Riyasat
    Kumar, Pradeep
    Yadav, Surendra
    Puntambekar, T. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [8] Measurements of dose rate for 10-16 keV Synchrotron X-ray photons at BL-16 beam line of Indus-2
    Sinhamahapatra, Debasis
    Haridas, G.
    Kumar, Pradeep
    Ghodke, A. D.
    Tiwari, M. K.
    Hannurkar, P. R.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2016, 54 (04) : 259 - 262
  • [9] RADIATION SAFETY ASPECTS OF THE OPERATION OF FIRST THREE SYNCHROTRON BEAM LINES OF INDUS-2
    Nayak, M. K.
    Nair, Haridas G.
    Bakshi, A. K.
    Sahani, P. K.
    Singh, Sunil
    Khan, Saleem
    Verma, Dimple
    Dev, Vipin
    Sahu, T. K.
    Khare, Mukesh
    Kumar, Vijay
    Bandyopadhyay, Tapas
    Tripathi, R. M.
    Sharma, D. N.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 187 - 193
  • [10] GIXRD measurements at EDXRD beamline at INDUS-2 Synchrotron
    Pandey, K. K.
    Kumar, Dileep
    Dwivedi, Abhilash
    Gupta, Ajay
    Sharma, Surinder M.
    SOLID STATE PHYSICS, PTS 1 AND 2, 2012, 1447 : 483 - +