Evaluation of Renal Function By Cystatin C in Renal Transplant Recipients

被引:4
|
作者
Ayub, Salma [1 ]
Zafar, Mirza Naqi [1 ]
Aziz, Tahir [2 ]
Iqbal, Tanweer [2 ]
Khan, Sadia [1 ]
Rizvi, S. Adibul Hasan [3 ]
机构
[1] Civil Hosp, Dept Chem Pathol, SIUT, Karachi 74200, Pakistan
[2] Civil Hosp, Dept Nephrol, SIUT, Karachi 74200, Pakistan
[3] Civil Hosp, Dept Urol & Transplantat, SIUT, Karachi 74200, Pakistan
关键词
Cystatin C; Kidney; Transplant; GLOMERULAR-FILTRATION-RATE; SERUM CREATININE; KIDNEY-FUNCTION; MARKER; PREDICTION;
D O I
10.6002/ect.2013.0202
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objectives: We evaluated cystatin C concentration as a marker of glomerular filtration rate in renal transplant recipients, and its correlation with creatinine-based glomerular filtration rate by urinary creatinine clearance, and the Cockroft-Gault and Modification of Diet in Renal Disease formulas. Materials and Methods: In this cross-sectional study, we measured serum cystatin C levels and its correlation with serum creatinine, creatinine clearance, and glomerular filtration rate using the Cockroft-Gault formula and Modification of Diet in Renal Disease formulas. Results: One hundred two recipients between June and December 2012, were examined. The mean subject age was 31.87 +/- 8.37 years; the male:female ratio was 4.3:1. Mean serum creatinine concentration was 141.44 +/- 43.31 mu mol/L (1.60 +/- 0.49 mg/dL) and serum cystatin C 122.09 +/- 38.95 nmol/L (1.63 +/- 0.52 mg/L). Serum cystatin C was significantly correlated with serum creatinine (r=0.90; P < .001), creatinine clearance (r=0.77; P <. 001), and the Cockroft-Gault (r=0.73; P <. 001) and the Modification of Diet in Renal Disease formulas (r=0.82; P < .001). We assessed the correlation among serum cystatin C with serum creatinine, creatinine clearance, the Cockroft-Gault and Modification of Diet in Renal Disease at 1, 2-3, 4-5, and more than 5 years after transplant. The correlation between serum cystatin C and serum creatinine ranged from 0.8 to 1.0; cystatin C and creatinine clearance ranged from 0.8 to 0.85; serum cystatin C and the Cockroft-Gault formula ranged from 0.7 to 0.8; and serum cystatin C and the Modification of Diet in Renal Disease formulas ranged from 0.8 to 0.84. Conclusions: Our results show that serum cystatin C is a reliable marker for estimating glomerular filtration rate among renal transplant recipients. This test can determine the glomerular filtration rate of renal transplant recipients on follow-up. Further studies are required to establish serum cystatin C as a standard test for monitoring glomerular filtration rate in transplanted patients.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [1] Cystatin C and renal function in pediatric renal transplant recipients
    Franco, M. C. P.
    Nagasako, S. S.
    Machado, P. G.
    Nogueira, P. C. K.
    Pestana, J. O. M.
    Sesso, R.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2009, 42 (12) : 1225 - 1229
  • [2] Serum cystatin C levels in renal transplant recipients
    Krishnamurthy N.
    Arumugasamy K.
    Anand U.
    Anand C.V.
    Aruna V.
    Venu G.
    Indian Journal of Clinical Biochemistry, 2011, 26 (2) : 120 - 124
  • [3] Cystatin C assay for the detection of renal dysfunction in Chinese renal transplant recipients
    Li, FK
    Ho, SKN
    Yip, TPS
    Tse, KC
    Chan, TM
    Lai, KN
    CLINICA CHIMICA ACTA, 2002, 322 (1-2) : 133 - 137
  • [4] Serum cystatin C concentrations in renal transplant recipients.
    Leach, TD
    Kitiyakara, C
    Thakkar, H
    Finney, H
    Stevens, JM
    Newman, DJ
    KIDNEY INTERNATIONAL, 1999, 55 (06) : 2588 - 2588
  • [5] Cystatin C assay for the detection of renal dysfunction in chinese renal transplant recipients.
    Li, FK
    Ho, SKN
    Chan, TM
    Lai, KN
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 772A - 772A
  • [6] Early diagnosis of renal function recovery by cystatin C in renal allograft recipients
    Thervet, E
    Le Bricon, T
    Hugot, V
    Benlakehal, M
    Bedrossian, J
    Beuzard, Y
    Legendre, C
    Erlich, D
    TRANSPLANTATION PROCEEDINGS, 2000, 32 (08) : 2779 - 2779
  • [7] Interest of cystatin C in the evaluation of renal function
    Delanaye, P
    Chapelle, JP
    Gielen, J
    Krzesinski, JM
    Rorive, G
    NEPHROLOGIE, 2003, 24 (08): : 457 - 468
  • [8] Evaluation of erectile function in renal transplant recipients
    Peskircioglu, L
    Tekin, MI
    Demirag, A
    Karakayali, H
    Özkardes, H
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (03) : 747 - 749
  • [9] Cystatin C as a Marker of Renal Injury in Pediatric Heart Transplant Recipients
    Goldberg, J. F.
    Street, T. A.
    Yu, X.
    Wang, J.
    Strelsin, J. R.
    Boston, U. S.
    Towbin, J. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S395 - S395
  • [10] Cystatin C as a marker of renal function in kidney transplant patients
    Mendiluce, A
    Bustamante, J
    Martin, D
    Santos, M
    Bustamante, R
    Pascual, P
    Jabary, NS
    Castañeda, A
    Muñoz, MF
    TRANSPLANTATION PROCEEDINGS, 2005, 37 (09) : 3844 - 3847