Measurement of solid circulation rate in a circulating fluidized bed

被引:19
|
作者
Matsuda, Satoru [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki, Japan
关键词
Solid mass flux; Solid circulation rate; Circulating fluidized bed; CFB; Optical mouse sensor;
D O I
10.1016/j.powtec.2008.02.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A method using an optical mouse sensor was developed to monitor the moving velocity of a solid mass. Calibration was carried out using a rotating plate. Results clarified that the developed method is useful to monitor the velocity up to some limit (v < 0.3 m/s), which depends on the optical mouse sensor used. A solid circulation rate in a circulating fluidized bed (CFB) was measured using this method. Results obtained using this method show agreement with those of visual observations. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 50 条
  • [1] Improvement of continuous solid circulation rate measurement in a cold flow circulating fluidized bed
    Ludlow, J. Christopher
    Monazam, Esmail R.
    Shadle, Lawrence J.
    POWDER TECHNOLOGY, 2008, 182 (03) : 379 - 387
  • [2] Estimation of the solid circulation rate in circulating fluidized bed systems
    Stollhof, Michael
    Penthor, Stefan
    Mayer, Karl
    Hofbauer, Hermann
    POWDER TECHNOLOGY, 2018, 336 : 1 - 11
  • [3] A STUDY OF SOLID CIRCULATION RATE IN A CIRCULATING FLUIDIZED-BED
    LUONG, PH
    BHATTACHARYA, SC
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1993, 17 (06) : 479 - 490
  • [4] Solid Circulation Rate in a Viscous Liquid-Solid Circulating Fluidized Bed
    Hong, Sung Kyu
    Jang, Hyung Ryun
    Lim, Dae Ho
    Yoo, Dong Jun
    Kang, Yong
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2016, 54 (05): : 706 - 711
  • [5] Solid circulation rate in a circulating fluidized bed in the presence of fine powders
    Mahmoud, EA
    Nakazato, T
    Nakagawa, N
    Kato, K
    CHEMICAL ENGINEERING SCIENCE, 2006, 61 (02) : 766 - 774
  • [6] Experimental study of the solid circulation rate in a pressurized circulating fluidized bed
    Hu, Jinding
    Liu, Daoyin
    Li, Heng
    Liang, Cai
    Chen, Xiaoping
    PARTICUOLOGY, 2021, 56 : 207 - 214
  • [7] Solid circulation rate in recirculating fluidized bed
    Alappat, BJ
    Rane, VC
    JOURNAL OF ENERGY ENGINEERING-ASCE, 2001, 127 (02): : 51 - 68
  • [8] Effect of various parameters on the solid circulation rate in a liquid-solid circulating fluidized bed
    Natarajan, P.
    Velraj, R.
    Seeniraj, R. V.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2008, 3 (04) : 459 - 470
  • [9] Prediction of solid circulation rate in an internal circulating fluidized bed: An empirical and ANN approach
    Varghese, Mona Mary
    Vakamalla, Teja Reddy
    Gujjula, Ravi
    Mangadoddy, Narasimha
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 88
  • [10] Estimate of solid flow rate from pressure measurement in circulating fluidized bed
    Monazam, Esmail R.
    Panday, Rupen
    Shadle, Lawrence J.
    POWDER TECHNOLOGY, 2010, 203 (01) : 91 - 97