Development of a Portable Mass Spectrometer Characterized by Discontinuous Sample Gas Introduction, a Low-Pressure Dielectric Barrier Discharge Ionization Source, and a Vacuumed Headspace Technique
被引:48
|
作者:
Kumano, Shun
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Kumano, Shun
[1
]
Sugiyama, Masuyuki
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Sugiyama, Masuyuki
[1
]
Yamada, Masuyoshi
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Yamada, Masuyoshi
[1
]
Nishimura, Kazushige
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Nishimura, Kazushige
[1
]
Hasegawa, Hideki
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Hasegawa, Hideki
[1
]
Morokuma, Hidetoshi
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi High Technol Corp, Hitachinaka, Ibaraki, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Morokuma, Hidetoshi
[2
]
Inoue, Hiroyuki
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Inst Police Sci, Kashiwa, Chiba 2770882, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Inoue, Hiroyuki
[3
]
Hashimoto, Yuichiro
论文数: 0引用数: 0
h-index: 0
机构:
Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, JapanHitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
Hashimoto, Yuichiro
[1
]
机构:
[1] Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo, Japan
[2] Hitachi High Technol Corp, Hitachinaka, Ibaraki, Japan
[3] Natl Res Inst Police Sci, Kashiwa, Chiba 2770882, Japan
The present study has attempted to downscale a mass spectrometer in order to make it portable and enable onsite analysis with it. The development of a small mass spectrometer required the use of a compact pump whose displacement was small, decreasing the sensitivity of that spectrometer. To get high sensitivity with a small mass spectrometer, we have integrated novel techniques: a highly sensitive ionization source and efficient extraction of sample vapor. The low-pressure dielectric barrier discharge ionization (LP-DBDI) source made it possible to increase the conductance between the source and the mass analyzer, compared with ambient ionization sources, enhancing the efficiency of the ion transfer from the ionization source to the mass analyzer. We have also developed a vacuumed headspace method efficiently transporting the sample vapor to the ionization source. The sensitivity was further enhanced by also using a discontinuous sample gas introduction technique. A prototype portable mass spectrometer using those novel techniques was found to be sensitive enough to detect 0.1 ppm methamphetamine, 1 ppm amphetamine, 1 ppm 3,4-methylenedioxymethamphetamine, and 10 ppm cocaine in liquid.