Direct surface plasmon resonance immunosensing of pyraclostrobin residues in untreated fruit juices

被引:21
|
作者
Mauriz, E. [1 ]
Garcia-Fernandez, C. [1 ]
Mercader, J. V. [2 ]
Abad-Fuentes, A. [2 ]
Escuela, A. M. [3 ]
Lechuga, L. M. [4 ,5 ]
机构
[1] Univ Leon, Inst Food Sci & Technol ICTAL, Leon 24007, Spain
[2] Spanish Natl Res Council, Inst Agrochem & Food Technol, Valencia 46100, Spain
[3] Univ Las Palmas GC, Inst Appl Microelect, IUMA, Las Palmas Gran Canaria 35001, Spain
[4] Res Ctr Nanosci & Nanotechnol CIN2 CSIC, Barcelona 08193, Spain
[5] CIBER BBN, Barcelona 08193, Spain
关键词
SPR; Biosensor; Immunoassay; Pyraclostrobin; Food analysis; FUNGICIDES; EXTRACTION; WINES;
D O I
10.1007/s00216-012-6321-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A surface plasmon resonance (SPR) immunoassay for on-line detection of the strobilurin fungicide pyraclostrobin in untreated fruit juices is presented. The analysis of pyraclostrobin residues is accomplished in apple, grape, and cranberry samples by monitoring the recognition events occurring separately in a two-channel home-made SPR biosensor. Covalent coupling of the analyte derivative results in a reversible method, enabling more than 80 measurements on the same sensor surface. Optimization of the immunoassay conditions provides limits of detection as low as 0.16 mu g L-1. The selectivity and reproducibility of the analysis is ensured by studying both non-specific interactions with unrelated compounds and inter-assay coefficients of variation. Excellent recovery ranging from 98 to 103 % was achieved by a simple 1:5 dilution of fruit juice with assay buffer before the analysis. The lack of previous cleaning and homogenization procedures reduces the analysis time of a single food sample to only 25 min, including the regeneration cycle.
引用
收藏
页码:2877 / 2886
页数:10
相关论文
共 50 条
  • [1] Direct surface plasmon resonance immunosensing of pyraclostrobin residues in untreated fruit juices
    E. Mauriz
    C. García-Fernández
    J. V. Mercader
    A. Abad-Fuentes
    A. M. Escuela
    L. M. Lechuga
    Analytical and Bioanalytical Chemistry, 2012, 404 : 2877 - 2886
  • [2] SURFACE-PLASMON RESONANCE APPLIED TO IMMUNOSENSING
    DANIELS, PB
    DEACON, JK
    EDDOWES, MJ
    PEDLEY, DG
    SENSORS AND ACTUATORS, 1988, 15 (01): : 11 - 18
  • [3] Surface Plasmon Resonance imaging applied to immunosensing
    Dutra, RF
    Neto, JOM
    Fontana, E
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 : 128 - 135
  • [4] Studies on amplified assay of surface plasmon resonance immunosensing
    Pei, R.
    Wang, E.
    Yang, X.
    Beijing Daxue Xuebao Ziran Kexue Ban/Acta Scientiarum uaturalium Universitatis Pekinensis, 2001, 37 (02): : 186 - 191
  • [5] Small Molecule Immunosensing Using Surface Plasmon Resonance
    Mitchell, John
    SENSORS, 2010, 10 (08) : 7323 - 7346
  • [6] A plasma polymerized film for surface plasmon resonance immunosensing
    Nakamura, R
    Muguruma, H
    Ikebukuro, K
    Sasaki, S
    Nagata, R
    Karube, I
    Pedersen, H
    ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4649 - 4652
  • [8] Colloidal Au-enhanced surface plasmon resonance immunosensing
    Lyon, LA
    Musick, MD
    Natan, MJ
    ANALYTICAL CHEMISTRY, 1998, 70 (24) : 5177 - 5183
  • [9] Detection of retromer assembly in Plasmodium falciparum by immunosensing coupled to Surface Plasmon Resonance
    Iqbal, Mohd Shameel
    Siddiqui, Asim Azhar
    Banerjee, Chinmoy
    Nag, Shiladitya
    Mazumder, Somnath
    De, Rudranil
    Saha, Shubhra Jyoti
    Karri, Suresh Kumar
    Bandyopadhyay, Uday
    BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS, 2018, 1866 (5-6): : 722 - 730
  • [10] Sensitivity enhancement of surface plasmon resonance immunosensing by antibody-antigen coupling
    Sun, Ying
    Liu, Xia
    Song, Daqian
    Tian, Yuan
    Bi, Shuyun
    Zhang, Hanqi
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (02) : 469 - 474