Non-destructive evaluation of articular cartilage defects using near-infrared (NIR) spectroscopy in osteoarthritic rat models and its direct relation to Mankin score

被引:66
|
作者
Afara, I. [1 ,3 ]
Prasadam, I. [3 ]
Crawford, R. [2 ,3 ]
Xiao, Y. [1 ,3 ]
Oloyede, A. [1 ,3 ]
机构
[1] Queensland Univ Technol, Fac Sci & Engn, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
[2] Prince Charles Hosp, Brisbane, Qld 4032, Australia
[3] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld 4001, Australia
基金
英国医学研究理事会;
关键词
Articular cartilage; Near-infrared (NIR) spectroscopy; Osteoarthritis; Non-destructive evaluation; Mankin score; ARTHROSCOPIC CLASSIFICATION; OBSERVER RELIABILITY; REFLECTANCE SPECTRA; KNEE; REPAIR;
D O I
10.1016/j.joca.2012.07.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to demonstrate the potential of near-infrared (NIR) spectroscopy for categorizing cartilage degeneration induced in animal models. Method: Three models of osteoarthritic degeneration were induced in laboratory rats via one of the following methods: (1) menisectomy (MSX); (2) anterior cruciate ligament transection (ACLT); and (3) intra-articular injection of mono-ido-acetate (1 mg) (MIA), in the right knee joint, with 12 rats per model group. After 8 weeks, the animals were sacrificed and tibial knee joints were collected. A custom-made near-infrared (NIR) probe of diameter 5 mm was placed on the cartilage surface and spectral data were acquired from each specimen in the wave number range 4,000-12,500 cm(-1). Following spectral data acquisition, the specimens were fixed and Safranin-O staining was performed to assess disease severity based on the Mankin scoring system. Using multivariate statistical analysis based on principal component analysis and partial least squares regression, the spectral data were then related to the Mankin scores of the samples tested. Results: Mild to severe degenerative cartilage changes were observed in the subject animals. The ACLT models showed mild cartilage degeneration, MSX models moderate, and MIA severe cartilage degenerative changes both morphologically and histologically. Our result demonstrates that NIR spectroscopic information is capable of separating the cartilage samples into different groups relative to the severity of degeneration, with NIR correlating significantly with their Mankin score (R-2 = 88.85%). Conclusion: We conclude that NIR is a viable tool for evaluating articular cartilage health and physical properties such as change in thickness with degeneration. (C) 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 50 条
  • [1] Evaluation of cartilage defects with near-infrared spectroscopy (NIR):: An ex vivo study
    Spaln, Gunter
    Plettenberg, Holger
    Nagel, Horst
    Kahl, Enrico
    Klinger, Hans Michael
    Mueckley, Thomas
    Guenther, Manfred
    Hofmann, Gunther O.
    Mollenhauer, Juergen A.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (03) : 285 - 292
  • [2] Non-destructive Detection of the Freshness of Garlic Powder Using Near-infrared (NIR) Spectroscopy and Chemometrics Techniques
    Mohammadigol, Reza
    Shahhoseini, Reza
    JOURNAL OF MEDICINAL PLANTS AND BY-PRODUCTS-JMPB, 2025, 14 (01): : 87 - 92
  • [3] Spatial mapping of proteoglycan content in articular cartilage using near-infrared (NIR) spectroscopy
    Afara, Isaac O.
    Moody, Hayley
    Singh, Sanjleena
    Prasadam, Indira
    Oloyede, Adekunle
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01): : 144 - 154
  • [4] NON-DESTRUCTIVE AND RAPID IDENTIFICATION OF BACTERIA USING NEAR-INFRARED SPECTROSCOPY
    Teiichi Matsunaga
    Kosei Kurosaka
    Pediatric Research, 1999, 45 : 922 - 922
  • [5] Near-infrared spectroscopy: a non-destructive tool for processing quality evaluation of potatoes
    Joshi A.
    Raigond P.
    Singh B.
    Indian Journal of Plant Physiology, 2017, 22 (2): : 258 - 262
  • [6] Non-destructive detection of physiological disorders in melons using near infrared (NIR) spectroscopy
    Ito, H
    Fukino-Ito, N
    Horie, H
    Morimoto, S
    PROCEEDINGS OF THE INTERNATIONAL WORKSHOP ON MODELS FOR PLANT GROWTH AND CONTROL OF PRODUCT QUALITY IN HORTICULTURAL PRODUCTION, 2004, (654): : 229 - 234
  • [7] Evaluation of Different Models for Non-Destructive Detection of Tomato Pesticide Residues Based on Near-Infrared Spectroscopy
    Nazarloo, Araz Soltani
    Sharabiani, Vali Rasooli
    Gilandeh, Yousef Abbaspour
    Taghinezhad, Ebrahim
    Szymanek, Mariusz
    SENSORS, 2021, 21 (09)
  • [8] Non-destructive determination of lycopene in tomatoes using visible/near-infrared spectroscopy
    Ito, Hidekazu
    Morimoto, Susumu
    Journal of the Illuminating Engineering Institute of Japan (Shomei Gakkai Shi), 2009, 93 (08): : 510 - 513
  • [9] Non-destructive determination of deoxynivalenol levels in barley using near-infrared spectroscopy
    Ruan, R
    Li, Y
    Lin, X
    Chen, P
    APPLIED ENGINEERING IN AGRICULTURE, 2002, 18 (05) : 549 - 553
  • [10] Progress in Non-destructive Citrus Quality Detection Using Near-infrared Spectroscopy
    Zhang X.
    Li P.
    Yu M.
    Jiang L.
    Liu X.
    Shan Y.
    Shipin Kexue/Food Science, 2022, 43 (01): : 260 - 268